Automatic Transformer Tangent Delta Power Factor Tester Electrical Instrument

Brand Name:AI
Certification:ISO
Model Number:TDT
Minimum Order Quantity:1 Set Power Factor Tester
Delivery Time:15 days
Payment Terms:T/T, Western Union, L/C
Contact Now

Add to Cart

Verified Supplier
Location: Changsha Hunan China
Address: Hi-tech Developing Industrial Area, Liuyang City,Changsha,Hunan Province,China
Supplier`s last login times: within 30 hours
Product Details Company Profile
Product Details

Capacitance Tangent Delta Power Factor Dielectric Loss Tester


I.Introduction:

Tangent delta tester is a high-precision instrument, which can be applied to automatically measure electrical loss tangent ( ) and capacitance of all kinds of high voltage electrical equipments on the spot of power plants, substations,laboratory, etc. The instrument is an integrated structure with a dielectric loss test bridge, a variable frequency power supply, a step-up transformer and a SF6 high stability standard capacitor.


II.Features:

★Large LCD display

Simple operation, the instrument is equipped with a high-end full touch LCD screen, super touch interface, and each process is very clear. Operators can use it without additional professional training.

★Mass storage data

The instrument is equipped with a calendar chip and large capacity memory. The test results can be stored in chronological order. Users can view historical data at any time and print it out.

★Multiple test modes

The instrument can be tested by high pressure, high voltage, standard, positive connection method, reverse connection method, self excitation method and other methods.

★CVT test step in place

The instrument can also test the full sealed CVT (capacitor voltage transformer) C1, C2 dielectric loss and capacitance, to achieve the C1, C2 simultaneous test.

★Do not dismantle the high-voltage lead measurement CVT

The instrument can accurately measure the dielectric loss and capacitance of CVT without dismantling the CVT high voltage lead.

★CVT reverse shield method for measuring C0

The instrument can be used to measure the dielectric loss and capacitance value of C0 on the upper end of CVT.

★High speed sampling signal

The inverter and sampling circuit of the instrument are all controlled by digital, and the output voltage is adjustable continuously.

★Multi protection security

The instrument has many protection measures, such as input voltage fluctuation, output short circuit, over voltage, over current and temperature.


II.Specifications:


1Use conditions-15℃∽40℃RH<80%
2Anti-interferenceFrequency conversion
3PowerAC 220V±10%Allowable generator
4High output0.5KV∽10KV(rated voltage:10KV)Every 0.1kV
0.5KV∽12KV(rated voltage:12KV)
Precision2%
Maximum current200mA (rated voltage:10KV)
167mA (rated voltage:12KV)
Capacity2000VA
5Self-excited powerAC 0V∽50V/15A45HZ/55HZ 47.5HZ/52.5HZ
55HZ/65HZ 57.5HZ/62.5HZ
Automatic double frequency
6Resolving powertgδ: 0.001%Cx: 0.001pF
7Precision△tgδ:±(Reading*1.0%+0.040%)
△C x :±(Reading*1.0%+1.00PF)
8measuring rangetgδUnlimited
C x15pF < Cx < 300nF
rated voltage:10KV10KVCx < 60 nF
5KVCx < 150 nF
1KVCx < 300 nF
rated voltage:12KV12KVCx < 30 nF
5KVCx < 150 nF
1KVCx < 300 nF
CVT testCx < 300 nF
9CVT range10∽10000
accuracy0.1%
Resolving power0.01
10Exterior dimension350(L)×270(W)×270(H)
11Memory sizeThe 200 groups supports U disk data storage
12Weight28 Kg
China Automatic Transformer Tangent Delta Power Factor Tester Electrical Instrument supplier

Automatic Transformer Tangent Delta Power Factor Tester Electrical Instrument

Inquiry Cart 0