50000m3/H Clean Room Air Handling Units rooftop packaged

Brand Name:Shenglin
Certification:CE
Model Number:SL-ZKW Series
Minimum Order Quantity:1
Delivery Time:35~40days
Payment Terms:T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Shanghai Shanghai China
Address: Room B321, Building No.1, No. 619, Longchang Road, Yangpu District, Shanghai,China
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details
Central Air Conditioner Chilled Water Type Air Handler

Products Features

1.Aluminum frame structure, high mechanical strength, light weight, corrosion resistance, good-looking appearance, accurate sizes. Flexible assembly structure, easily assembly and maintenance, service life is longer than the steel frame.

2.Double skin polyurethane color steel panel, no cold bridges.

3.Double air inlet centrifugal fans, by the strict dynamic and static balance test, smoothly running, small vibration. Closed rolling bearing, automatically aligning and automatically self-locking, anti-push and other functions, pre-filled with lubricating oil, normally use without maintenance.

4.Plate filter can be cleaned many times.

5.Has function of air supply, cooling, heating, dehumidifying, humidification, air filtration and noise reduction etc.

6.Suitable for the air conditioning system for electronics, instrumentation, machinery, metallurgy, chemical industry, textile, medicine, food, tobacco, transportation, energy and other industries.

Technical Data:
Chilled Water Air Handing Unit Spec. Table No. 1
Model SL-ZKW-20406080100150200250300
Air volume(m³/h)20004000600080001000015000200002500030000
Outlet air pressure(pa)300300400500500600750750750
Supply fan capacity(kw)1.11.52.245.511151518.5
Cooling4 RowsReturn air(kw)12.223.935.9486090120150179
water flow(m³/h)2.24.26.18.210.515.320.423.828.2
all fresh air(kw)2243.86290112156210265310
water flow(m³/h)3.87.71115.519.227.336.545.855
pipe diameter (DN)253240404050656580
6 RowsReturn air(kw)1730.145.26075113151188210
water flow(m³/h)2.85.37.710.513.619.225.530.236
all fresh air(kw)30.55888118150200288355420
water flow(m³/h)5.11015.220.226.235.5497072.5
pipe diameter (DN)323240405065658080
8 RowsReturn air(kw)18.335.2537090132176220264
water flow(m³/h)3.26.28.912.216.222.230.237.244.2
all fresh air(kw)34.870101138178245332410500
water flow(m³/h)5.81217.523.530.842.557.17185
pipe diameter (DN)323240405065658080
Heating2 RowsReturn air(kw)20426084108150200250300
water flow(m³/h)0.81.92.63.74.66.58.71113
all fresh air(kw)18385470100125180210280
water flow(m³/h)0.81.72.43.24.55.57.81012
pipe diameter (DN)253240404040505065
4 RowsReturn air(kw)285680110140200250320380
water flow(m³/h)1.22.43.54.86.391113.518.2
all fresh air(kw)326290125150220300380450
water flow(m³/h)1.52.73.85.46.89.513.516.219.5
pipe diameter (DN)323240404050506565
Function section
outside dimension
Mixing sectionLength(mm)500500500550600800800800800
Width(mm)9509501080125016001600200022002200
Height(mm)9809801080125013201470168018802200
Pre-filter sectionLength(mm)100100100100100100100100100
Width(mm)9509501080125016001600200022002200
Height(mm)9809801080125013201470168018802200
Medium efficiency filter sectionLength(mm)500500500500500500500500500
Width(mm)9509501080125016001600200022002200
Height(mm)9809801080125013201470168018802200
Cooling coil sectionLength(mm)60060070070070080080010001000
Width(mm)9509501080125016001600200022002200
Height(mm)9809801080125013201470168018802200
Heating sectionLength(mm)300300300400400400400400400
Width(mm)9509501080125016001600200022002200
Height(mm)9809801080125013201470168018802200
Humidifying sectionLength(mm)400400400400400400400400400
Width(mm)9509501080125016001600200022002200
Height(mm)9809801080125013201470168018802200
Fan sectionLength(mm)50050090040011001400160017001850
Width(mm)9509501080125016001600200022002200
Height(mm)9809801080125013201470168018802200
Current balance sectionLength(mm)400400500900500600600600700
Width(mm)9509501080125016001600200022002200
Height(mm)9809801080125013201470168018802200
Sound deadening sectionLength(mm)800800800500800100010001000100
Width(mm)9509501080125016001600200022002200
Height(mm)9809801080125013201470168018802200
Air outlet sectionLength(mm)400400400800500600600800800
Width(mm)9509501080125016001600200022002200
Height(mm)9809801080125013201470168018802200
1. Cooling condition: supply and return water temp7/12℃,
indoor dry bulb/ wet bulb temp35/28℃, fresh air dry bulb/ wet bulb temp35/28℃

2. Heating condition conditions: supply and return water temp60/50℃,
indoor dry bulb/ wet bulb temp20/ -℃, fresh air dry bulb/ wet bulb temp7/6℃

3. The air volume, residual pressure and power in the table are standard parameters,
and are able to be customized

4. Heater, humidifier and heat recovery device are optional, which can be configured as spacific form according to customer's requirements

5. G4 filter is adopted as the unit standard, which can be configured as other form according to customer's requirements

6. The length and size are determined by the functional sections. Please consult us for details.


Application:

The units are widely used in the air system of many inductries like mechanical ,electronic, textile,medical,chemical,energy and foo inductries ,etc. the units are also ideal solution for restaurants, office buildings,hospitals,theaters,supermarkets and palaestra.

China 50000m3/H Clean Room Air Handling Units rooftop packaged supplier

50000m3/H Clean Room Air Handling Units rooftop packaged

Inquiry Cart 0