3D Positioning Automatic Tonometer 60mm Hg Xyz Stable Data Of IOP

Brand Name:SYSEYE
Certification:TUV
Model Number:ST-1000
Minimum Order Quantity:1
Delivery Time:5 working days
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Chongqing Chongqing China
Address: 2nd floor of building #5, 27 Fengsheng Road, Jinfeng Town,High-Tech Industrial Development Zone, 401329 Chongqing, People's Republic of China
Supplier`s last login times: within 28 hours
Product Details Company Profile
Product Details

automatic tonometer auto 3D positioning of xyz stable data of IOP


St-1000 is a non-contact tonometer with automatic alignment. The test of intraocular pressure is an important index for clinical diagnosis of ophthalmology. Our st-1000p non-contact tonometer adopts non-contact measurement with no risk of infection, simple operation and easy acceptance by patients.

St-1000 adopts Imber-Fick principle and USES controllable air pulse with linear increasing characteristics to squeeze the central position of the cornea and deform the cornea to form a circular plane with a diameter of about 3.6mm2. It is considered that the air pressure at this time is equal to the pressure inside the eyeball, and the measured air pressure at this time is the value of the intraocular pressure directly.


Automatic Tonometer specification


Intraocular pressure (IOP) measuring range1mmHg~ 30mmHg /1mmHg ~60mmHg ( precision of 1mmHg)
Measuring systemdual sensor system of light and pressure
Working distance≥11mm
R/Lautomatic detection and display
Measuring result10 times per eye; 3 times result printing per eye
Recordingbuild-in printer
Measuring modeauto/manual
Movement range≥30mm(front to back)/ 90mm(left to right)/ 30mm(vertical)
Jaw layer vertical movement≥30mm(front to back)/ 90mm(left to right)/ 30mm(vertical)
Display mode10.1-inch HDMI color LED touch monitor
Output portUSB2.0

Main safety features of the product:

A, classified according to prevent electric shock type: Ⅰ such equipment.

Ii. Classification according to the degree of anti-electric shock: type B application part.

Iii. Classification according to the degree of protection against liquid intake in GB/T 4208: common type.

Iv. Classification according to the degree of safety in the use of flammable anesthetic gas mixed with air or with oxygen or nitrous oxide: it shall not be used in the use of flammable anesthetic gas mixed with air or with oxygen or nitrous oxide.

V. classification by operation mode: intermittent loading and continuous operation.

Rated voltage and frequency of the equipment: a.c.220 V/50 Hz.

Input power of medical electrical equipment: 200VA, input power of medical electrical system: 200VA.

Whether the equipment has the application part that should be protected against the defibrillation discharge effect: none.

Whether the device has a signal output part: it has a signal input and output part.

X. permanent installation equipment or non-permanent installation equipment: non-permanent installation equipment.




Company Introduction


Focusing on the two major public health problems of adolescent myopia and elderly ophthalmology, our company researches new diagnostic and treatment equipment for ophthalmology, develops low-cost applicable technology products, realizes industrialization, reduces the cost of social medical and health system, and serves the strategic needs of national health.The company always adhere to the "high-tech,new vision" for the enterprise development concept.We have a strong technical force, has been awarded 11 patents, and obtained 13,485 quality system certification.Bio has established an efficient marketing team and a perfect after-sales service system to provide medical equipment with the highest cost performance and meticulous service.

China 3D Positioning Automatic Tonometer 60mm Hg Xyz Stable Data Of IOP supplier