COOLNET CJA Rack Mounted Precision Air Conditioner for Large Data Centers
Product Introduction
The Rack Mounted Precision Air Conditioner is a cutting-edge cooling solution designed specifically for large data centers. It ensures optimal temperature and humidity control, creating an ideal environment for sensitive electronic equipment. This compact and efficient air conditioner is designed to be installed directly in server racks, saving valuable floor space. Benefits |
Advantages
By maintaining a consistent temperature and humidity level, the air
conditioner promotes optimal performance and longevity of your data
center equipment.
The redundant design and intelligent features minimize the risk of
equipment failure and ensure continuous operation, reducing costly
downtime.
The rack-mounted design saves valuable floor space, allowing you to
accommodate more servers and equipment within the data center.
The energy-efficient operation of the air conditioner helps reduce
electricity costs, contributing to long-term savings.
The unit is designed for easy installation and maintenance,
ensuring hassle-free operation and reducing downtime during
maintenance activities. |
Application
This precision air conditioner is ideal for cooling large-scale
data centers that require precise temperature and humidity control.
It can also be used in server rooms of various sizes, ensuring
reliable cooling for critical equipment.
The air conditioner is suitable for telecommunication facilities
that house networking equipment, ensuring their optimal performance
and reliability. |
Indoor Unit Parameters
Model-CJA | 0003 | 0005 | 0007 | 0012 | |||
Phase/Function | 1.5P,Single Phase | 2P,Single Phase | 3P,Single Phase | 5P,Single Phase | |||
Parameters | |||||||
Cooling capacity kW | 3.5 | 5 | 7.5 | 12.5 | |||
Sensible cooling capacity k | W 3.5 | 5 | 7.5 | 12.5 | |||
Air volume m³/h | 800 | 1150 | 1600 | 2300 | |||
Sensible heat ratio % | 100 | 100 | 100 | 100 | |||
Heating kW (Option) | 1 | 1 | 2 | 3 | |||
Maximum operating current A | 15 | 15 | 25 | 34 | |||
Power Cord Cable Specifications | mm 3×2.5 | 3×2.5 | 3×4 | 3×6 | |||
Indoor/outdoor unit shut-off valve | |||||||
Refrigerant gas pipe φ mm | 12.7 | 12.7 | 12.7 | 15.88 | |||
Refrigerant liquid pipe φ mm | 9.52 | 9.52 | 9.52 | 9.52 | |||
Indoor unit structural parameters | |||||||
Dimension:W×D×H mm | 442×714×175 (4U) 442×714×218 (5U) | 442×714×218 (5U) | 442×714×351 (8U) | 442×714×440 (10U) | |||
Outdoor Unit | |||||||
Type-CJT | 3005 | 3005 | 3008 | 3013 | |||
Quantity | 1 | 1 | 1 | 1 |
Outdoor Unit Parameters
Type- CJT | 3005 | 3005 | 3008 | 3013 | |||
Power supply | 220Vac/1Ph/50Hz | ||||||
Installation | Vertical | ||||||
Speed mode | Stepless speed regulation | ||||||
Noise dBA | 54 | 55 | 56 | 58 | |||
Rated current A | 6 | 6 | 10 | 15 | |||
Power Cord Cable Specifications | mm 4×1.5 | 4×1.5 | 4×2.5 | 4×4 | |||
Communication cable specificati mm (with shielding function) | on 3×1 | 3×1 | 3×1 | 3×1 | |||
Structural parameters of outdoor unit | |||||||
Dimension:W×D×H mm | 840×285×610 | 840×285×610 | 880×360×800 | 930×390×1270 |