Home /Air Conditioners /

Chilled Water Cooled Precision Air Conditioning Units For Mission Critical

Chilled Water Cooled Precision Air Conditioning Units For Mission Critical

Brand Name:Coolent
Certification:ISO/CE
Model Number:CYCN51D/U
Minimum Order Quantity:1Unit
Delivery Time:20-30Days
Payment Terms:T/T, L/C
Contact Now

Add to Cart

Verified Supplier
Location: Hefei Anhui China
Address: Room 303, 3rd Floor, Building C, Yingte Workshop, West Section of Yanglin Road, High-tech Zone Mechanical and Electrical Industrial Park, Hefei City Anhui Province
Supplier`s last login times: within 1 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Chilled-Water Cooled Precision Air Conditioning units for mission-critical

Products Introduction

CyberMaster series precision air conditioning system adopts international cutting-edge constant temperature and constanthumidity technology, which is designed and developed for a precision environment. This series of products is dedicated to equipments with high precision control requirements of temperature, humidity, and cleanliness and requires equipment continuous operation 24 hours*365 days.

Advantage

Multiple options

A variety of air supply methods: up / down / down air supply with sinking fan

Type: single cooling, Cooling + heating, Cooling + humidifying, constant temperature and humidity

High reliability

All specifications are rigorously lab tested

According to 365 days x 24hr operation requirements

The design and selection of unit equipment is higher than the industrial standard International first-class brand components

High efficiency and energy saving

Quick dehumidification design to avoid over-starting of electric heating

Copeland Scroll compressors designed for high reliability and durability, high efficiency, low noise, adjustable air volume and pressure

Evaporator V - shaped structure, reasonable airflow organization, high heat exchange efficiency

Large-area condenser with fan stepless speed control, lower energy consumption

Chilled Water Cooled Precision Air Conditioning Units For Mission Critical

Applications

Chilled Water Cooled Precision Air Conditioning Units For Mission Critical

„ Computer room and data center

„ Switch room and mobile center station in telecommunication

„ High-tech environment and lab

„ Industrial automation control room and precision manufacturing workshop

„ Standard test room and calibration center

„ UPS and battery room

„ Test room in hospital

„ Biochemical culture chamber

Technical Parameters

Model: CYC N31 D/U N41 D/U N51 D/U N60 D/U N71 D/U N82 D/U N91 D/U N100 D/U N112 D/U N121 D/U N131 D/U N140 D/U N152 D/U N160 D/U N171 D/U N180 D/U N190 D/U N200 D/U
Specification (Chilled water T 7/12℃)28℃/40%RH
Total Capacity (1) KW 31.5 41.5 51.5 60.5 71 82.5 91.5 101.5 112.5 121.5 131 140 152 160.5 171.5 180 190 200
Sensible KW 28 37 45.5 53.5 63 73.3 81 90 100 108 115.5 124.3 134.8 142.5 151.5 159.5 169 177.5
Water Flow L/S 5.4 7.1 8.9 10.4 12.2 14.2 15.7 17.5 19.3 20.9 22.5 24.1 26.1 27.6 29.5 31 32.7 34.4
Water Pressure Drop Kpa 60 66 72 65 70 66 75 80 73 81 72 81 88 75 83 90 85 95
Specification (Chilled water T10/15°C) 28℃/40%RH
Total Capacity (1) KW 27.5 36.5 45 53.5 62.5 72.5 80.5 89.5 99.5 107.5 115.7 123.5 134 142 151 159 168.5 177
Sensible KW 27.5 36.5 45 53.5 62.5 72.5 80.5 89.5 99.5 107.5 115.7 123.5 134 142 151 159 168.5 177
Water Flow L/S 4.7 6.3 7.7 9.3 10.7 12.5 13.8 15.4 17.1 18.5 19.9 21.2 23 24.4 26 27.3 29 30.4
Water Pressure Drop Kpa 55 60 68.5 59 65 60.5 70 74 69 75 68.5 75.5 76 71.5 73 80 75 85
EC Fan
Fan quantity PC 1 1 1 1 1 2 2 2 2 2 2 2 3 3 3 3 3 3
Airflow m3/h 7500 9500 11000 12500 14500 18500 21500 22500 23500 24500 26000 27500 30500 32500 35000 37500 38500 39500
Excess press outside (2) Pa 20-300 Adjustable
Reheat Section
Total heating capacity KW 6 6 6 6 6 9 9 9 9 9 9 9 12 12 12 12 12 12
Rated Current A 10 10 10 10 10 14 14 14 14 14 14 14 19 19 19 19 19 19
Level n 2 2 2 2 2 2 2 2 2 2 2 2 3 3 3 3 3 3
Humidifier Section Electrode type
Capacity Kg/h 5 5 5 5 5 13 13 13 13 13 13 13 13 13 13 13 13 13
Rated power KW 3.75 3.75 3.75 3.75 3.75 9.75 9.75 9.75 9.75 9.75 9.75 9.75 9.75 9.75 9.75 9.75 9.75 9.75
Rated Current A 6 6 6 6 6 15 15 15 15 15 15 15 15 15 15 15 15 15
Physical
Length mm 915 915 915 915 915 1790 1790 1790 1790 1790 1790 1790 2665 2665 2665 2665 2665 2665
Depth mm 980 980 980 980 980 980 980 980 980 980 980 980 980 980 980 980 980 980
Height mm 1975 1975 1975 1975 1975 1975 1975 1975 1975 1975 1975 1975 1975 1975 1975 1975 1975 1975
Weight KG 254 283 286 305 476 477 478 526 528 530 570 702 705 738 750 752 755 770
Breakers & Cables
Recommended Breaker A 20 20 20 25 25 30 30 30 40 40 40 40 40 50 50 50 50 50
Cables mm2 4 4 4 6 6 10 10 10 10 10 10 10 10 16 16 16 16 16

Certificates

Chilled Water Cooled Precision Air Conditioning Units For Mission Critical

Factory Details

Chilled Water Cooled Precision Air Conditioning Units For Mission Critical

Packing & Delivery

Chilled Water Cooled Precision Air Conditioning Units For Mission Critical

China Chilled Water Cooled Precision Air Conditioning Units For Mission Critical supplier

Chilled Water Cooled Precision Air Conditioning Units For Mission Critical

Inquiry Cart 0