30-40KW 600mm Wide In Row Air Conditioners For Precise Data Centers And Computing Places
Product Introduction Coolnet Cool-row series computer room in-row precision air conditioning unit is a control system that satisfies the precision environment. It is suitable for large, medium and small computer rooms, modular computer rooms, data centers using micro-modules and cold/hot aisles, and for energy-saving, high-heat Environmental control of computer rooms where density is required. Features ● High sensible heat ratio design, cooling near the heat source, horizontal return air, short air circulation path, high efficiency ● Intelligent load monitoring, which can detect data in real time, adjust the output in real time, and the output cooling capacity intelligently follows the calorific value of the load, effectively improving the timeliness of system maintenance ● Optional dual power input components are used in the occasion of dual power supply at the end to improve the availability and reliability of the unit | ||||
Advantages | Efficient - save money and space ● Adopt high-efficiency EC fan, with soft-start function, multiple fans are evenly distributed, air flow is uniform without dead angle, and heat exchange efficiency is improved ● The fan adopts hot-swappable design, which is easy to maintain, ensuring high efficiency and energy saving, and achieving redundancy ● The outdoor unit fan adopts variable frequency stepless speed regulation control, energy saving, noise reduction and long service life High intelligence - time saving ● Standard RS485 communication interface to realize remote monitoring, optional SNMP and TCP/IP interface to improve the efficiency of communication interconnection and meet users' various needs for energy linkage, monitoring and inspection, etc. ● Rich alarm and protection functions in the system, support up to 18 remote temperature sensors, good temperature control technology ● Easy networking to optimize cost and time High reliability - no worry ● Adopt DC inverter compressor, dynamic cooling, adapt to the rapidly changing heat load of the machine room, reduce the frequent start and stop of the compressor, and improve the system reliability ● Fan online hot-swappable and redundant design, easy to maintain, ensure high efficiency and energy saving while achieving redundancy to protect equipment from running continuously |
Technical Parameter
Model | CRA013A | CRA020A | CRA040A | CRA050A | CRA060A |
Air supply | Front/Side | Front/Side | Front | Front | Front |
Power supply | 380VAC/3Ph/50Hz | ||||
Cooling capacity-KW | 13.2 | 26.7 | 42.6 | 53.3 | 63.9 |
Sensible cooling-KW | 13.2 | 26.7 | 42.6 | 53.3 | 63.9 |
Compressor | |||||
Refrigerant | R410A | ||||
Quantity | 1 | ||||
Fan | |||||
Fan type | EC Centrifugal fan | ||||
Quantity | 4 | 5 | 2 | 3 | 3 |
Air volume-m3/h | 3200 | 5000 | 8800 | 11000 | 12500 |
Heater | |||||
Heat type | PTC | ||||
Capacity-KW | 2 | 3 | 6 | 6 | 6 |
Humidification | |||||
Capacity-KW | 1 | 1.5 | 3 | 3 | 3 |