InRow Precision AC Unit For Over Heated In Server Rooms And Data Centers

Brand Name:COOLNET
Certification:CE,ISO
Model Number:XR012, 040
Minimum Order Quantity:1set
Delivery Time:10-25 working days
Payment Terms:T/T, L/C
Contact Now

Add to Cart

Verified Supplier
Location: Hefei Anhui China
Address: Room 303, 3rd Floor, Building C, Yingte Workshop, West Section of Yanglin Road, High-tech Zone Mechanical and Electrical Industrial Park, Hefei City Anhui Province
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Precision In-Row AC Specialized For Partially Over-Heated In Server Rooms And Data Centers

Product Introduction


The increasing development of the information age and the continuous increase of equipment in the server rooms and data centers, has resulted in an increasing maintenance cost of the equipment. The use of Cool-Row in-row air conditioners can keep the computer room in a constant temperature and humidity state, improve the heat dissipation efficiency of server rooms and DC, and maintain the smooth operation of the equipment in the computer room throughout the year. To a great extent, it protects the life of the equipment, while also maximizing production efficiency and reducing company costs.


Advantages

  • Close to the heat source; Short air flow path and small cooling capacity loss;
  • High adaptability to high return air temperature; High matching degree with the output air temperature of equipment;
  • Ultra-high energy efficiency ratio, energy saving, and low operating cost;
  • Ultra-high sensible heat ratio, less excessive dehumidification;
  • High reliability, long life design: 24*365 uninterrupted operation design, the design life is 10 years;
  • Multiple high-efficiency backward-inclined centrifugal direct-connected fans, air volume redundancy design

Application Range

  • Internet Data center(IDC)
  • Partially overheated computer room
  • High heat density computer room
  • High energy-saving demand room
  • Modular Data Center
  • Containerized data center

Features

Energy Efficiency

  • Inverter compressor, EC fan and electronic expansion valve are standard configurations for DXA series
  • Air is directly drawn from the hot aisle, allowing the unit to take advantage of higher heat transfer efficiency due to higher Delta T.
  • Cold aisle/Hot ailse containment avoids mixing of cold and hot air

High Flexibility

  • Air-cooled or chilled water-cooled cooling scheme.
  • Scalability reduce initial investment, more units can be easily added in the row as the demand for cooling increases.
  • High Reliability & Serviceability
  • 24*7 uninterruptible operation design.
  • Multiple units in data centers, the total cooling capacity will not lower too much until the failed unit can be repaired.
  • Secondary water tray.
  • Hot-swappable fans.
  • Highly safety performance guaranteed by functions and protections designed for the unit.

Intelligent Control System

  • Highest protection against downtime, equipment damage and excess wear and tear.
  • Touched screen interface offers the full visibility.
  • AIRSYS NetOne Monitoring & Control for multiple units teamwork. integrated the latest technology of AI and ML to provide the monitoring and reliability for a more efficient operation of the cooling system.

Technical Parameter


ModelCRA013ACRA020ACRA040ACRA050ACRA060A
Air supplyFront/SideFront/SideFrontFrontFront
Power supply380VAC/3Ph/50Hz
Cooling capacity-KW13.226.742.653.363.9
Sensible cooling-KW13.226.742.653.363.9
Compressor
RefrigerantR410A
Quantity1
Fan
Fan typeEC Centrifugal fan
Quantity45233
Air volume-m3/h3200500088001100012500
Heater
Heat typePTC
Capacity-KW23666
Humidification
Capacity-KW11.5333

Certificates


Factory Details



Delivery & Packing


Cases


China InRow Precision AC Unit For Over Heated In Server Rooms And Data Centers supplier

InRow Precision AC Unit For Over Heated In Server Rooms And Data Centers

Inquiry Cart 0