Dynamic Cooling System In-Row Air Conditioner Units For Data Center Heat Dissipation


Product Introduction


The air-conditioning cabinets and fans of the in-row air conditioners are arranged in a dense arrangement of multiple rows and multiple rows. The characteristics of large air volume, uniform air supply, and good heat exchange effect enhance the cooling effect of the air conditioner and eliminate the problem of local hot spots in the computer room. Cool-row in-row air conditioners are also more energy-efficient, more efficient, and have lower overall noise, which directly improves the problem of high energy consumption and high noise in the computer room.

Application


  • Internet Data center(IDC)
  • Partially overheated computer room
  • High heat density computer room
  • High energy-saving demand room
  • Modular Data Center
  • Containerized data center

Structure & Components

DC Inverter Compressor

  • Dynamic cooling to adapt to the rapidly changing load of the computer room;
  • Save energy and improve energy efficiency under low load;
  • It can greatly reduce the number of compressor starts and stops, and improve system reliability.

Backward Centrifugal EC Fan

  • Compared with ordinary standard AC motors, the electronically commutated synchronous EC motors can save energy by 30%;
  • Automatically adjust the fan speed according to the cooling demand or wind pressure, and provide the air volume on demand;
  • Fan N+1 redundant configuration, any fan failure can still ensure full air volume operation;
  • Soft start function, low starting current.

Air Supply Method


Technical Parameter

ModelCRA013ACRA020ACRA040ACRA050ACRA060A
Air supplyFront/SideFront/SideFrontFrontFront
Power supply380VAC/3Ph/50Hz
Cooling capacity-KW13.226.742.653.363.9
Sensible cooling-KW13.226.742.653.363.9
Compressor
RefrigerantR410A
Quantity1
Fan
Fan typeEC Centrifugal fan
Quantity45233
Air volume-m3/h3200500088001100012500
Heater
Heat typePTC
Capacity-KW23666
Humidification
Capacity-KW11.5333

Certificates