In Row Precision Air Conditioning For Heat Radiation Of Large Data Centers


Product Introduction


The in-row air conditioner is a kind of heat dissipation equipment arranged in the rack of the cabinet and installed side by side with the server cabinet. The traditional computer room air conditioner is generally far away from the heat source because it needs to adjust the temperature of the internal space of the entire room so that the effect is uneven and the energy consumption is large. However, the in-row air conditioner can be close to the heat source, it can directly dissipate heat from the heat source. Its heat dissipation efficiency is higher and it is more conducive to saving energy. Therefore, the in-row air conditioner has been more and more widely used in the cabinet in the computer room for heat dissipation.


Main Applications

  • Data center with single rack above 3kW
  • High heat density computer room
  • Partially overheated computer room
  • Modular DC
  • Container DC
  • Low PUE data center
  • Renovation of local hot spots in the computer room

Advantages & Features

EVO Control System

  • Graphic display, including the running status and the temperature/humidity of the inlet/outlet air
  • Advanced team work function, up to 32 units and easy to set network
  • Standard RS485 port, optional SNMP, TCP/IP interfaces, and GPRS with SMS
  • Standard communication protocol, optional customized specifications
Electronically Commutated Compressor
  • R410A
  • Compressor speed is infinitely variable dependent on the heat load
  • Energy saving under partial-load mode, improving energy efficiency
  • Significant reduce the start/stop frequency of the compressor
  • Improve the system reliability

Options

  • Transfer switch for Dual Power Input
  • Baffles
  • Low-temperature startup kits
  • GPRS SMS alarm
  • Wired temperature/humidity sensors
  • Three-way water valve

Product Details


ModelCRA013ACRA020ACRA040ACRA050ACRA060A
Air supplyFront/SideFront/SideFrontFrontFront
Power supply380VAC/3Ph/50Hz
Cooling capacity-KW13.226.742.653.363.9
Sensible cooling-KW13.226.742.653.363.9
Compressor
RefrigerantR410A
Quantity1
Fan
Fan typeEC Centrifugal fan
Quantity45233
Air volume-m3/h3200500088001100012500
Heater
Heat typePTC
Capacity-KW23666
Humidification
Capacity-KW11.5333