R410A In Row Air Conditioner For Partially Over Heated Server Rooms 5000 M3/H

Brand Name:COOLNET
Certification:CE,ISO
Model Number:CR, XR012A, XR023A
Minimum Order Quantity:1set
Delivery Time:10-25 working days
Payment Terms:T/T, L/C
Contact Now

Add to Cart

Verified Supplier
Location: Hefei Anhui China
Address: Room 303, 3rd Floor, Building C, Yingte Workshop, West Section of Yanglin Road, High-tech Zone Mechanical and Electrical Industrial Park, Hefei City Anhui Province
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

In-Row Air Conditioner Units For Partially Over-Heated Server Rooms 5000 M3/H


Product Introduction

The electronic equipment in the server rooms usually emits a lot of heat during operation. And if too many electronic devices are placed in the computer room of a data center, it will cause local heat accumulation and fail to effectively dissipate heat. Furthermore, the life of the electronic equipment is lost, and even circuit failure is caused. Therefore, a reasonable and efficient heat dissipation device is urgently needed in the computer room.


According to this situation, Coolnet power designed the Cool-row series of in-row air conditioners. This air conditioners can completely solve the problem of short-circuit of cold and hot air flow through the horizontal air supply method of supplying air from the cold aisle and then returning the air from the hot aisle, ensuring the uniform temperature of the server cabinet, eliminating local hot spots, and increasing the number of servers. The reliability of the operation at the same time effectively reduces unnecessary energy consumption.


Feature & Benefits

Applications

  • Data center with single rack above 3kW
  • High heat density computer room
  • Partially overheated computer room
  • Modular DC
  • Container DC
  • Low PUE data center
  • Renovation of local hot spots in the computer room

Advantages

EVO Control System

  • Graphic display, including the running status and the temperature/humidity of the inlet/outlet air
  • Advanced team work function, up to 32 units and easy to set network
  • Standard RS485 port, optional SNMP, TCP/IP interfaces, and GPRS with SMS
  • Standard communication protocol, optional customized specifications
  • Electronically Commutated Compressor

R410A

  • Compressor speed is infinitely variable dependent on the heat load
  • Energy saving under partial-load mode, improving energy efficiency
  • Significant reduce the start/stop frequency of the compressor
  • Improve the system reliability

Options

  • Transfer switch for Dual Power Input
  • Baffles
  • Low-temperature startup kits
  • GPRS SMS alarm
  • Wired temperature/humidity sensors
  • Three-way water valve

Technical Parameter


ModelCRA013ACRA020ACRA040ACRA050ACRA060A
Air supplyFront/SideFront/SideFrontFrontFront
Power supply380VAC/3Ph/50Hz
Cooling capacity-KW13.226.742.653.363.9
Sensible cooling-KW13.226.742.653.363.9
Compressor
RefrigerantR410A
Quantity1
Fan
Fan typeEC Centrifugal fan
Quantity45233
Air volume-m3/h3200500088001100012500
Heater
Heat typePTC
Capacity-KW23666
Humidification
Capacity-KW11.5333

Certificates