40KW R410A Precision Air Conditioners For Laboratory Constant Temperature

Brand Name:Coolent
Certification:ISO/CE
Model Number:CYAS40D/U
Minimum Order Quantity:1
Delivery Time:4W
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Hefei Anhui China
Address: Room 303, 3rd Floor, Building C, Yingte Workshop, West Section of Yanglin Road, High-tech Zone Mechanical and Electrical Industrial Park, Hefei City Anhui Province
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Precision Laboratory Precision Air Conditioner And Constant Temperature And Humidity Air Conditioner


Product Introduction

Precision air conditioners are designed for data centers, computer rooms, and network centers. All series of precision air conditioners for computer rooms use modular energy-saving planning principles, and different types of special precision air conditioners are announced according to different users. The electronic equipment in the communication room releases a lot of sensible heat. According to the characteristics of the room, the high sensible heat ratio of 0.9 or more is achieved. When used in the environment of the computer room, it consumes about 20-30% of the energy consumption compared with ordinary comfort air conditioners, and thus avoids excessive Dehumidification and air supply are foggy.


Feature and Benefits

Application

  • Large, medium and small exchange room
  • Large data center
  • Paging machine room and communication machine room
  • Microwave and satellite ground station
  • Field base stations and mobile telecommunications
  • Network management center and small computer room
  • UPS power room and battery room
  • Archives and Museum
  • CT and MRI room
  • Biochemical Incubation Room
  • Standardize testing rooms and calibration centers
  • Precision workshop and dust-free workshop
  • Laboratory and high-precision environment
  • Medical testing room
  • Industrial Process Control Center

Advantages


High reliability:

All components of the precision air conditioning unit in the computer room include high-efficiency scroll compressors, protection-free backward-tilting centrifugal fans, etc., which are planned and manufactured in accordance with 24 hours a day and 365 days a year. In order to reach the longest operating time and the least repair costs.


Two-speed air supply:

High-speed air supply can provide the most air volume and maximum cooling capacity. Low-speed air supply can provide maximum dehumidification capacity and corresponding cooling capacity. The wind speed of the air supply is adjusted automatically.


High energy efficiency ratio compressor:

Use a scroll compressor with a high energy efficiency ratio. The reduction of the moving parts of the scroll compressor reduces the noise and sensation of the unit a lot; the compression process of the compressor is continuous and stable;


High-efficiency and low-noise backward-inclined centrifugal fan:

Use the efficient and low-noise EBM backward tilt centrifugal wind motorized balance test to ensure long life, high energy efficiency, low energy consumption and low noise operation. Compared with equipment with the same air volume in the industry, the power consumption is the lowest.


Stepless speed regulation and low noise air-cooled condenser:

The air-cooled condenser is made of marine grade corrosion-resistant materials, has outstanding rigidity and anti-corrosion functions, and is accustomed to various environmental conditions. Fully adjustable speed electric fans are used to achieve energy saving and low noise.


Technical Parameters

Model: CYAT26D/UT31D/UT35D/UT41D/UT45D/UT50D/UT55D/UT61D/UT70D/UT76D/UT85D/UT90D/UT100D/U
Power Supply380V 3Ph-50HZ
Air DischargeUpflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity (1)KW26.931.935.941.945.350.555.461.470.576.285.590.8102
SensibleKW24.829.533.138.842.547.851.657.565.271.279.584.595.7
AEERW/W3.63.63.63.63.63.73.73.63.63.63.63.63.6
Air Flowm3/h800095001000011500130001550016000175001850020500225002350024200
Compressor Hermetic scroll
RefrigerantR407C
Compressor quantityPC2222222222222
Fan Section Centrifugal fan (Optional EC)
Fan quantityPC2222222223333
Rated currentA4.34.34.34.44.44.455.25.26.516.516.516.5
Rated powerW1600160018001800200020003000330039003900540063006300
Total heating capacityKW66699999912121212
MaterialPTC
Humidifier Section Electrode type
CapacityKg/h5555131313131313131313
Rated CurrentA6666151515151515151515
Condenser Model2*582*582*582*582*802*802*1002*1002*1202*1502*1502*1652*180

Certificates


Factory Details


Packing and Deluvery


Case


China 40KW R410A Precision Air Conditioners For Laboratory Constant Temperature supplier

40KW R410A Precision Air Conditioners For Laboratory Constant Temperature

Inquiry Cart 0