300mm Air Cooled In Row Air Conditioning Unit For Server Room

Brand Name:COOLNET
Certification:CE,ISO
Model Number:CR012
Minimum Order Quantity:1set
Delivery Time:10-25 working days
Payment Terms:T/T, L/C
Contact Now

Add to Cart

Verified Supplier
Location: Hefei Anhui China
Address: Room 303, 3rd Floor, Building C, Yingte Workshop, West Section of Yanglin Road, High-tech Zone Mechanical and Electrical Industrial Park, Hefei City Anhui Province
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

300mm Air Cooled In Row Air Conditioning Unit For Server Room


Product Introduction

A row-oriented design allows cooling capacity and redundancy3 to be targeted to the actual needs of specific rows. For example, row-oriented architecture allows one row of racks to run high density applications such as blade servers, while another row satisfies lower power density applications such as communication enclosures. Similarly, mission critical servers can be installed in one row that features redundant cooling, and less important workloads can reside on servers in a row without redundant cooling.


A row-oriented architecture can be implemented without a raised floor. This increases the floor load bearing capacity, reduces installation costs, eliminates the need for access ramps, and allows data centers to exist in buildings that otherwise do not have the headroom to permit the installation of a raised floor.


Feature & Benefits

Safe and reliable

  • The start-up current is small, which can reduce the impact on the power grid;
  • Expert self-diagnosis and fault warning function to ensure operation;
  • Fan N+1 redundant configuration, to avoid equipment operation obstacles caused by unexpected situations;
  • Dual power input, safer and more reliable

Intelligent control

  • Standard RS485 interface, support ModBus protocol;
  • Optional Ethernet interface, support TCP/IP/SNMP protocol;
  • Optional remote monitoring module, which can remotely read unit information through web, WeChat, official account, and APP;
  • Can be connected to multiple temperature and humidity sensors, multiple point detection;
  • Only group control can realize unbalanced load area coordination

Scope of Application

  • Single rack with power larger than 3kW

  • High heat density computer room

  • Modular DC

  • Container type DC

  • DC with low PUE

  • Hot spot reconstruction

Technical Parameter


ModelCRA013ACRA020ACRA040ACRA050ACRA060A
Air supplyFront/SideFront/SideFrontFrontFront
Power supply380VAC/3Ph/50Hz
Cooling capacity-KW13.226.742.653.363.9
Sensible cooling-KW13.226.742.653.363.9
Compressor
RefrigerantR410A
Quantity1
Fan
Fan typeEC Centrifugal fan
Quantity45233
Air volume-m3/h3200500088001100012500
Heater
Heat typePTC
Capacity-KW23666
Humidification
Capacity-KW11.5333