Stulz Close Control Unit Air Conditioning , 45KW Data Center Air Conditioner

Brand Name:Coolent
Certification:ISO/CE
Model Number:CYAT40D/U
Minimum Order Quantity:1
Delivery Time:4W
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Hefei Anhui China
Address: Room 303, 3rd Floor, Building C, Yingte Workshop, West Section of Yanglin Road, High-tech Zone Mechanical and Electrical Industrial Park, Hefei City Anhui Province
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Stulz Close Control Unit Air Conditioning , 45KW Data Center Air Conditioner


Products Introduction

Coolnet, with more than 30 years’ R&D and manufacturing experience in server room equipment field, depending on world-class labs, inspection and production equipment, not only can provide specialized products to meet the exact requirement of user’s job site, but also provide a perfect total solution for server room. Now our product range include precision air conditioner, UPS and data center solution.

CyberMasterTM Series Precision Cooling Unit: With high AEER system design and team work function, CyberMasterTM meets the cooling demand and reduce the PUE of the data center.


Benefits

Applications

„ Computer room and data center

„ Switch room and mobile center station in telecommunication

„ High-tech environment and lab

„ Industrial automation control room and precision manufacturing workshop

„ Standard test room and calibration center

„ UPS and battery room

„ Test room in hospital

„ Biochemical culture chamber

Features

1. High quality control component.

2. Efficient evaporator made from advanced technology and with larger heat exchange area.

3. Danfoss brand quality expansion valve.

4. Internationally advanced electrode steam humidification system.

5. Unique frame design guarantees the cabinet safety under any transport condition and operating environment.

6. G4 level air filter to guarantee the server room air purity.

7. Copeland hermetic scroll compressor.

8. Standard configuration with speed adjustable centrifugal fan. EC fan is optional.

9. Highly efficient PTC electrical heater.

10. Anti-corrosion alloy condenser.


Technical Parameters

Model: CYAT26D/UT31D/UT35D/UT41D/UT45D/UT50D/UT55D/UT61D/UT70D/UT76D/UT85D/UT90D/UT100D/U
Power Supply380V 3Ph-50HZ
Air DischargeUpflow/Downflow
Cooling Capacity :24℃/50%RH
Total Capacity (1)KW26.931.935.941.945.350.555.461.470.576.285.590.8102
SensibleKW24.829.533.138.842.547.851.657.565.271.279.584.595.7
AEERW/W3.63.63.63.63.63.73.73.63.63.63.63.63.6
Air Flowm3/h800095001000011500130001550016000175001850020500225002350024200
Compressor Hermetic scroll
RefrigerantR407C
Compressor quantityPC2222222222222
Fan Section Centrifugal fan (Optional EC)
Fan quantityPC2222222223333
Rated currentA4.34.34.34.44.44.455.25.26.516.516.516.5
Rated powerW1600160018001800200020003000330039003900540063006300
Total heating capacityKW66699999912121212
MaterialPTC
Humidifier Section Electrode type
CapacityKg/h5555131313131313131313
Rated CurrentA6666151515151515151515
Condenser Model2*582*582*582*582*802*802*1002*1002*1202*1502*1502*1652*180

Certificates


Factory Details


Packing & Delivery


Case


China Stulz Close Control Unit Air Conditioning , 45KW Data Center Air Conditioner supplier

Stulz Close Control Unit Air Conditioning , 45KW Data Center Air Conditioner