Quick Details:


Place of Origin: Shenzhen, China (Mainland)Rated Cooling Capacity : 400W
Brand Name: ESTELRated Heating Capacity:300W/500W(optional)
Model: TC06-40JFH/01Dimension: H×W×D 520×360×187mm
Product Name: Outdoor Enclosure Air ConditionerInput Voltage: AC220V/50Hz
Certification: ISO9001, CE, 3C, FCC, TLCRated Input Current: 0.9A
Cover: including outer coverRated Input Power: 198W
Color: greyWorking Temperature: -20°C ~ +55°C
Protection Level: IP55Noise: ≤55dB
Installation Mode: door mounted, side mountedRefrigerant: R134a
Support OEMCooling Method: compressor, active cooling

Payment & Shipping Terms:


Minimum Order Quantity:1 set
Price:negotiation
Payment Terms:L/C, D/A, D/P, T/T, Western Union
Supply Ability:15,000 sets per month
Delivery Time:10-15 working days
Packaging Details:carton + wooden case

1. Specifications

(1) Technical Parameters


Environmental Performanceworking environmental temperature-20°C ~ 55°C
storage temperature-40°C ~ 70°C
working humidity≤95%
Thermal Performancerated cooling capacity

450W(L35 L35)

400W(L25 L35)


Electrical Performance

rated input current

1.0A(L35 L35)

0.9A(L25 L35)

rated input power

220W(L35 L35)

198W(L25 L35)

input voltageAC220V/50Hz (185V~264V)

Dimension Diagram: H×W×D: 520×360×187mm


Size

Model

SpecsABCDEFGHIJK
TC06-120JFH/01(KT041)1200W300401450600671695190220650378424

Size

Model

SpecsABCDEFGHIJK
TC06-120JFH/01(KT041)1200W300401450600671695190220650378424

2. Description


TC06-40JFH/01 Air Conditioner is a full automation temperature control product. It uses intelligent controller to control the whole system of the air conditioner. According to the variation of environment temperature, the intelligent controller can automatically detect, operate and record the whole system’s operating time, power consumption, event and historical data. It can store 100 event records and 1280 historical data records, and can enquire 256 days’ daily record information.


Cabinet air conditioner is actively cooling with compressor, and it will remove the heat inside the cabinet to outside. It also can keep the dust and heat outside the cabinet, avoiding problems from using fan. The inside cabinet can be maintained at an ideal temperature for electrical components which effectively guarantees the stability of the electronic equipment and improves the reliability of the whole system.


3. Application


The air conditioner is widely applied in outdoor telecom cabinet, battery cabinets, electric cabinets, industry control cabinets, small and medium sized telecom room, UPS room, outdoor base station room, etc.

4. Features


  • Strong adaptability
  • High intelligence
  • High precision
  • High reliability
  • Low noise
  • Low energy consumption
  • With 4 way switching value detection
  • With 1 way room air conditioner control
  • Voltage input range: 220VAC±15% 50Hz
  • With dry contact alarm output

5. System Principle Diagram


6. Electrical Wiring Diagram


Wiring Ports:


L N PE : power supply port (voltage input: 220VAC±15% 50Hz)

F+ F- : direct ventilation output port

AL1 AL2: general alarm output port

A+ B- SGND: RS485 communication port

N: not connected pin


7. System Control

7.1 Function and Application


ET731 intelligent air conditioner controller is a universal intelligent controller, controlling with highly integrated STC SCM. It can intelligently control thermostatic cabinet air conditioner working and hydrogen exhausting, including functions such as fault self diagnosis, power-on self start, or restart after unexpected failure caused by other reasons. The controller is compatible with all types of air conditioners in the market.

The controller, with the features of advanced performance, easy installation and setting, are widely used in telecom cabinet, small and medium sized telecom room, UPS room, outdoor base station room, etc.

7.2 Technical Parameter


  • 2×16 Chinese/English shift LCD display, user friendly;
  • Simultaneously display temperature and humidity inside the box and communication room temperature;
  • Temperature measurement accuracy: 0.1 °C; humidity measurement accuracy:5%;
  • Can store 180 days’ daily event record, 1 record every day;
  • Daily highest temperature, lowest temperature, average temperature
  • Daily event record;
  • Save the former day’s daily data at 0:00 every day; Can query 180 days’ daily record information;
  • RS485 communication, YD/T 1363.1-2005 standard protocol, support remote detection and control;
  • Control mode: pulse (Non dry contact air conditioner), conducting (dry contact air conditioner)
  • Real-time control air conditioner on/off
  • Power supply: AC185V~264V/50Hz;
  • Power consumption:≤5W;
  • Working environment: -30°C~70°C; <90%RH;
  • Installation method: guide rail, hanging;
  • Dimension(L×W×H):150×190×45mm

7.3 Operating Instruction


ET731 uses English interfaces, which can be operated easily. All the operations can be realized with four buttons. The following is the control board diagram:


a. Check operating parameters of key parts inside air conditioner, namely observation parameter. Operation steps:


Observation Parameter: on the left of line 1 is Parameter No. (PAnn); on the right of line 1 is parameter value. Line 2 shows the remark of the parameter.


b. Revise operating parameters of air conditioner, namely control parameters. Operation steps:



Control Parameter: on the left of line 1 is Parameter No. (PCnn), on the right of line 1 is parameter value. Line 2 shows the remark of the parameter.


c. Revise basic parameters of air conditioner. Operation steps:



Basic Parameter: on the left of line 1 is Parameter No. (PBnn), on the right of line 1 is parameter value. Line 2 shows the remark of the parameter.


d. Manual Operation Mode:


Operation steps:



Enter the interface to select “Cool” (cooing), “Heater” (heating), “Air” (direct ventilation) to conduct manual start (ON) and stop (OFF) operation.


e. Event Query Mode:


Operation steps:


8. Mainboard Wiring Diagram


9. Packing and Shipping



Our Delivery Agent


The goods can be shipped by sea, by air, by courier, by land, by train, etc.

Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.


10. Our Contact Information


Mobile Phone: 0086-13752765943

Telephone: 0086-0755 66600941

Email: info@estel.com.cn

lxf.estel@hotmail.com
Skype: fiona.liang10

China 400W Active Cooling Outdoor Cabinet Air Conditioner Cutomized Low Noise supplier

400W Active Cooling Outdoor Cabinet Air Conditioner Cutomized Low Noise

Inquiry Cart 0