Differential Scanning Calorimeter DSC / OIT Tester Test Melting Point , Glass Transition Temperature

Brand Name:BAXIT
Certification:CE,ISO
Model Number:BXT-DSC-600
Minimum Order Quantity:1
Payment Terms:T/T
Place of Origin:CHINA
Contact Now

Add to Cart

Verified Supplier
Location: Shanghai Shanghai China
Address: No.5616th, Caoan Road, Jiading District, Shanghai
Supplier`s last login times: within 38 hours
Product Details Company Profile
Product Details
BAXIT Differential Scanning Calorimeter
BXT-DSC-600

Product introduction

DSC is designed to determine the inner heat transition relating to temperature and heat flow, it is widely used in the field of polymer development, performance testing & quality control. DSC research and development includes the following field: glass transition temperature, melting point, cold crystallization, crystallization, phase transition, oxidation induction time (OIT).

The following figure is a typical DSC curve, showing four types of transitions:

I is the second-order transition, which is the change of horizontal baseline

is the endothermic peak, which is caused by the melting or melting transition of the sample

is the endothermic peak, which is caused by the decomposition or cracking reaction of the sample

Ⅰ Ⅱ Ⅲ Ⅲ Ⅳ is the exothermic peak, which is the result of crystal phase transition of the sample


Instrument interface:

a.The "Initial State" key is used to view real-time temperature, DSC and atmosphere information.

b."Parameter setting" key is used to set experimental parameters, which are usually set on software.

c. "Equipment Information" key to display equipment information. The administrator channel internal

personnel calibrate the temperature usage.

Software operation:

1. enter new in the menu bar of "file", as shown in the following figure

2. After clicking "New", you will switch to a new window. In the new window, enter information such as [Sample Name], [Sample Quality], [Operator], [Experimental Parameters], [Atmosphere], etc. The test type is selected as non-OIT according to customer requirements, and click [Connect Instrument]. You'll hear a noise. Pay attention to the two experiments, and the sample names cannot be the same.Otherwise, the overlay cannot be saved.


Parameter setting of oxidation induction period experiment

After the software setting is completed, connect the instrument, click the "△" start button in the upper left corner of the
software, the equipment will heat up according to the set program, and the software will record the data in real time.


After the experiment is completed, there will be a map. First, save the map to prevent it from being lost. And then analyze it.

Oxidation induction analysis process:
left strike turns green-analysis-oxidation induction period;

MAIN CONFIGURATIONS

Host1
U disk1
data wire; data cable2
Power cord1
Aluminum crucible200
Metal cover2
Raw tape1
10A fuse1
Sample spoon/pressure bar/tweezers2
aurilave1
Trachea1
Instructions2
Warranty1
certificate1

Company introduction:


1. who are we?
We are based in Shanghai, China, start from 2017,sell to North America(20.00%),Western Europe(15.00%),South America(10.00%),Oceania(10.00%),Northern Europe(10.00%),Eastern Europe(10.00%),South Asia(5.00%),Southern Europe(5.00%),Central America(5.00%),Africa(5.00%),Southeast Asia(5.00%),Eastern Asia(0.00%),Domestic Market(0.00%),Mid East(0.00%). There are total about 5-10 people in our office.

2. how can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;

3.what can you buy from us?
Differential Scanning Calorimeter, Thermogravimetric Analyzer, Differential Thermal Analyzer, Oxygen Bomb Calorimeter, Spot Cooler, Laboratory Equipment

4. why should you buy from us not from other suppliers?
We have 10 years of experience in design and development. The price preferential benefit There is a lot of goods in stock The service is good

5. what services can we provide?
Accepted Delivery Terms: FOB,CFR,CIF,EXW,FAS,CIP,FCA,DDU,Express Delivery,DAF;
Accepted Payment Currency:USD;
Accepted Payment Type: T/T,Credit Card,Western Union;
Language Spoken:English,Chinese
Our Services

If you encounter with any problems during the testing process,we promise providing urgent guidence and after-sales sevice within 48 hours and solution providing within 3 working days. If customers require on-site service, the transport and travel expense shall be responsible for the cost.

1. Pre-service

24 Hours online service for customers' consultation.

2. Middle service

-- Fullfill customer's request:

-- Payment method depends on customer.

-- Promptly production and delivery

-- Can provide invoice value if you want to decrease your tax.

3. After sale service

-- One year warranty service and all life maintenance.

-- Technical Egineer are avalible for oversea trainning.

-- Remote control technical consult

China Differential Scanning Calorimeter DSC / OIT Tester Test Melting Point , Glass Transition Temperature supplier

Differential Scanning Calorimeter DSC / OIT Tester Test Melting Point , Glass Transition Temperature

Inquiry Cart 0