TBBX Low Voltage Local Reactive Power Compensator 1-100Kvar 400V

Brand Name:BAIKONG
Certification:IEC,GB
Model Number:TBBX
Minimum Order Quantity:1set(MOQ)
Delivery Time:15Days OR To be negotiated
Payment Terms:L/C, Western Union, T/T
Contact Now

Add to Cart

Active Member
Address: D5-4 Workshop 389 3rd Section, East third Ring Road, Industrial Development Zone ,Pengzhou City, Sichuan Province
Supplier`s last login times: within 14 hours
Product Details Company Profile
Product Details

TBBX Low Voltage Power Factor Correction Without Power In Local Compensation Device


Application


TBBX type high voltage reactive local compensating device (hereinafter call compensating device) is of indoor use, for rated voltage 6-10KV, 50Hz, system to locally compensate reactive power for 6-10KV 3-P AC motor and to lessen the electric loss, improve electric quality and motor starting performance, the compensating device will be switched on/off along with the motor on/off. The effect is better than the central compensation.


Main technical data:

The basic parameters in situ compensator


No.TypeRated voltage(kV)Rated capacity of
capacitor group(Kvar)
Rated current of
capacitor group (A)
Protection modeShunt capacitor model
1TBBX6-90-3N6.6907.9

Each capacitor unit

has fuse protection

BFM6.6//3-30-1
2TBBX6-120-3N1210.5BFM6.6//3-40-1
3TBBX6-150-3N15013.1BFM6.6/3-50-1
4TBBX6-180-3N18015.75BFM6.6/3-60-1
5TBBX6-200-3N20017.5BFM6.6/6-200-3
6TBBX6-240-3N24021BFM6.6/6-80-3
7TBBX6-300-3N30026.2BFM6.6//3-100-1
8TBBX6-360-3N36031.5BFM6.6//3-120-1
9TBBX6-450-3N45039.4BFM6.6//3-150-1
10TBBX6-600-3N60052.5BFM6.6//3-200-1
11TBBX10-90-3N10904.7BFM11/3-30-1
12TBBX10-120-3N1206.3BFM11/3-40-1
13TBBX10-150-3N1507.9BFM11/3-50-1
14TBBX10-180-3N1809.45BFM11//3-60-1
15TBBX10-200-3N20010.5BFM11-200-2
16TBBX10-240-3N2402.6BFM11-80-3
17TBBX10-300-3N30015.75BFM11/3-100-1
18TBBX10-360-3N36018.9BFM11//3-120-1
19TBBX10-450-3N45023.6BFM11//3-150-1
20TBBX10-600-3N60031.5BFM11/3-200-1

Model and implication



Working Conditions


  1. Indoor use
  2. Altitude not more than 1000m
  3. Ambient temperature: -10~ 40
  4. Mounting sites shall have no bacterium, corrosive gas, explosive particles, conductive dusts, and no severe vibration
  5. Relative humidity: daily average: < 95%, month average: < 90%
  6. This device is only suitable for continuous working motor that it has no severe fluctuated loading, inverse rotation or inverse braking is forbidden, and it is not allowed to connect with speed adjustable motor.
  7. Rated voltage: 6-10KV
  8. Rated capacity as above sheet
  9. Rated current as above sheet.
  10. Wiring mode: Y (star) connected, neutral line earthed

Structure


The enclosure of the device can be made of panel material or steel bent formation, the panel upper part is meter door, downward part is steel door, inside door is provided with safe lock, rear panel is left ventilating door which it is locked by spiral lock, at normal working, this do or is not allowed to open except that the power is out of supply.


Selection


  • Rated voltage of the device shall be equal the system voltage
  • Rated voltage of the device shall be not bigger than motor no-loading current.
  • Calculation of compensated capacity: as the methods of GGJ low voltage reactive auto compensation device.

External Size


China TBBX Low Voltage Local Reactive Power Compensator 1-100Kvar 400V supplier

TBBX Low Voltage Local Reactive Power Compensator 1-100Kvar 400V

Inquiry Cart 0