Combined European Packaged Transformer Substation Maintenance Free

Brand Name:Baikong
Certification:IEC,GB
Model Number:YBW
Minimum Order Quantity:10 Pieces(MOQ)
Delivery Time:5...15Days OR To be negotiated
Payment Terms:T/T,, L/C, Western Union
Contact Now

Add to Cart

Active Member
Address: D5-4 Workshop 389 3rd Section, East third Ring Road, Industrial Development Zone ,Pengzhou City, Sichuan Province
Supplier`s last login times: within 14 hours
Product Details Company Profile
Product Details

Combined maintenance-free outdoor pre-installed European-style substation


The main technical parameters


The main technical parameters
Serial numbernameunitHigh-voltage electrical appliancestransformerLow-voltage electrical appliances
1Rated voltageKV6/106/0.4 10/0.40.4
2Rated CapacityKVA50-1600
3Rated currentA200,400,630100-3200
4Rated short-circuit breaking currentALoad switch 400-63015-63KV
KACombination switch depends on fuse
5Rated short-time withstand currentKA16,20(4S)15(1S)
30(1S)
6Rated peak withstand currentKA31,5.5030
63
7Power frequency withstand voltage (1MIN)KVRelatively and alternately 32/4225/35 (oil diffused)≤0.3,2
Height port 36/4820/28 (dry type)>0.3,2.5
8Lightning impulse withstand voltage (peak value)KVRelatively and alternately 32/4260/75
Isolated port 70/85
9Cabinet protection levelIP44
10Noise levelab55
11Executive standardGB/T 17467 "High-voltage and low-voltage prefabricated substation"
DL/T537 "6-35KV box-type substation ordering technical conditions"

Overview


European-style box-type substations(MV/LV Prefabricated Substations) arrange high-voltage, distribution transformers, low-voltage power distribution devices, and electric energy metering equipment into a compact power distribution device according to a certain circuit plan, with a small footprint.


device installation


(1) The location of the box transformer should be close to the load center. According to the load distribution of the district, the load moment is calculated to determine the load center. The box transformer should be installed near the load center. Power loss ≤12%, improve voltage quality Convenient operation and maintenance

(2) Strong vibrations and shocks are not allowed in the use location of the box substation, and no large electromagnetic induction intensity is allowed. For the buried circuit of the box substation, the laying path of each circuit outlet should be arranged, and the safety distance to the underground facilities should be arranged. , And does not affect the long-term development of the power supply area;

(3) The place of use must not have explosive dangerous substances, and the surrounding medium must not contain gases that corrode metals and destroy insulation and conductive media;

(4) The vertical inclination angle of the cabinet installation should not exceed 5°, the outdoor wind speed should not exceed 35m/s, and the relative air humidity should not exceed 90% (25°C);

(5) The installation of box substation does not require the construction of a control room and corresponding workshops. There is no structure for 10kV equipment and a small area. The site only needs to make a reinforced concrete foundation according to the size of the box substation provided by the manufacturer;

(6) Appropriate lifting equipment should be selected for hoisting according to the standard weight and relevant safety regulations. The angle of the hoisting wire rope is less than 60°. When hoisting, the rope should be used to pull the box diagonally to ensure its stable position;

(7) The European box transformer has been debugged before leaving the factory, only need to connect the box transformer high voltage and low voltage cables to the box transformer;

(8) Lightning rods should be arranged around the cabinet and the main transformer, and the equipment should be within its safety protection range. The grounding grid should be buried before the prefabricated foundation, and the grounding resistance should be less than 4Ω. Connect the ground terminal of the box firmly to it;

(9) Since the European-style box substation has reached the technical requirements of unattended operation, there is no need to set up background equipment. When operating, it is necessary to consider strengthening the anti-theft.


China Combined European Packaged Transformer Substation Maintenance Free supplier

Combined European Packaged Transformer Substation Maintenance Free

Inquiry Cart 0