Boronate Affinity Method POCT HbA1c Analyzer 2 Minutes Whole Blood Sample Type

Brand Name:LABNOVATION
Certification:IFCC, NGSP, CE
Model Number:LD-100
Minimum Order Quantity:1
Delivery Time:15-20 working days
Payment Terms:D/A, D/P, T/T
Contact Now

Add to Cart

Active Member
Location: Shenzhen China
Address: 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China
Supplier`s last login times: within 29 hours
Product Details Company Profile
Product Details

POCT HbA1c Analyzer Bronate Affnity Fluorescence Quenching Principle For Glycosylated Hemoglobin Test​


POCT HbA1c Analyzer Bronate Affnity Fluorescence Quenching Principle For Glycosylated Hemoglobin Test is intended for detecting glycoslated hemoglobin (HbA1c) in human blood.


According to the most recent IDF data, 537 million people—approximately 10% of all people aged 20-79 in the world—were living with diabetes as of 2021.



Specification


ModelLD-100
MethodBoronate Affinity
Measurement Time≤2 minutes
Sample TypeWhole blood
Measurement Range4.0-15%
Sample Volume4μL
Shelf life of test kit9 months
Weight≤800g
Dimensions192(L)*128(W)*108(H)mm


Principle


The analyzer works based on the principle of boric acid affinity fluorescence quenching. The content of HbA1c is quantitatively detected by detecting the amount of fluorescent substance changing with the binding and quenching of HbA1c and fluorescent substance.


The Application of Boronate affinity in Individual Test Cartridge POCT HbA1c Analyzer For Glycosylated Hemoglobin Test.


After the magnetic beads are pushed into the kit, the borate in the reagent binds to the fluorophore in the magnetic beads, resulting in a large amount of excited fluorescence

After the magnetic beads are pushed into the kit, the borate binds to the fluorophore, producing a large amount of excited fluorescence.

After the sample is added to the reagent, the borate-fluorophore competes with hemoglobin for binding, resulting in a decrease in fluorescence. Because the binding force of unglycated hemoglobin is much greater than that of glycated hemoglobin, the unglycated hemoglobin first binds to the borate-fluorophore, resulting in a sharp drop in fluorescence. The content of unglycated components can be detected during this process.

Next, the glycosylated hemoglobin is bound to a borate-fluorophore. This binding process is slow and therefore the fluorescence quenching process is slow and curvilinear. The fluorescence quenching process in the detection cycle of the instrument can reflect the content of glycosylated hemoglobin.



Feature


Boronate affinity Method: The HbA1c assay has no interference from common Hb variants

Ease of use: One-step operation the instrument is ready for use.

• Less than 3-minute test time

• A compact, lightweight instrument, Compact Size - To Minimize Space Requirements.

• With no need for bulky liquid reagents, LD-100 also free up more space in laboratories, clinics, blood banks, and other situations.

• Traceable to the IFCC Reference Method for HbA1c;Results reporting unit: IFCC units (mmol/mol) and NGSP units (%%).




Certificate


China Boronate Affinity Method POCT HbA1c Analyzer 2 Minutes Whole Blood Sample Type supplier

Boronate Affinity Method POCT HbA1c Analyzer 2 Minutes Whole Blood Sample Type

Inquiry Cart 0