Boronate Affnity HbA1c Analyzer Poct For Glycated Hemoglobin Test


The Boronate Affnity HbA1c Analyzer Poct For Glycated Hemoglobin Test is a fully automated desktop point-of-care analyzer for measuring glycated hemoglobin (HbA1c).



Feature


Boronate affinity Method: The HbA1c assay has no interference from common Hb variants

Ease of use: One-step operation the instrument is ready for use.

• Less than 3-minute test time

• A compact, lightweight instrument, Compact Size - To Minimize Space Requirements.

• With no need for bulky liquid reagents, LD-100 also free up more space in laboratories, clinics, blood banks, and other situations.

• Traceable to the IFCC Reference Method for HbA1c;Results reporting unit: IFCC units (mmol/mol) and NGSP units (%%).



Specification


ModelLD-100
MethodBoronate Affinity
Operating TypeFully automatic
Measurement Time≤2 minutes
Sample TypeWhole blood
Measurement Range4.0-15%
Sample Volume4μL
Shelf life of test kit9 months
Weight≤800g
Dimensions192(L)*128(W)*108(H)mm


Reliable

IFCC calibratorNormalAbnormalNormalAbnormal
Mean HbA1c%5.49.65.39.2
CV (%)2.5%1.9%2.4%1.8%


Performance Parameters

  • Accuracy: Is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Precision:Samples with a concentration of 4.0%-6.5% are detected, sample coefficient of variation (CV) of the test results is not more than 3%.
  • Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficientrof the test results should be no less than 0.9900.
  • Stability:Within 8 hours after the instrument is turned on and stable, the relative deviation of the test results is not more than ±3%.
  • Functions of the analyzer:The function of report output in English; Abnormal alarm function.