Whole Blood Sample POCT HbA1c Analyzer 2 Minutes Fully Automated Haematology Analyser

Brand Name:LABNOVATION
Certification:IFCC, NGSP, CE
Model Number:LD-100
Minimum Order Quantity:1
Delivery Time:15-20 working days
Payment Terms:D/A, D/P, T/T
Contact Now

Add to Cart

Active Member
Location: Shenzhen China
Address: 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China
Supplier`s last login times: within 29 hours
Product Details Company Profile
Product Details

POCT HbA1c Analyzer Fully Automated Analyzer For Glycosylated Hemoglobin Hba1c Test


The POCT HbA1c Analyzer Fully Automated Analyzer For Glycosylated Hemoglobin Hba1c Test is a fully automated desktop point-of-care analyzer for measuring glycated hemoglobin (HbA1c).
The Test Cartridge is individually packaged containing the reagents necessary for the determination of hemoglobin A1c one test.



Feature


Boronate affinity Method: The HbA1c assay has no interference from common Hb variants

Ease of use: One-step operation the instrument is ready for use.

• Less than 3-minute test time

• A compact, lightweight instrument, Compact Size - To Minimize Space Requirements.

• With no need for bulky liquid reagents, LD-100 also free up more space in laboratories, clinics, blood banks, and other situations.

• Traceable to the IFCC Reference Method for HbA1c;Results reporting unit: IFCC units (mmol/mol) and NGSP units (%%).



Specification


ModelLD-100
MethodBoronate Affinity
Operating TypeFully automatic
Measurement Time≤2 minutes
Sample TypeWhole blood
Measurement Range4.0-15%
Sample Volume4μL
Shelf life of test kit9 months
Weight≤800g
Dimensions192(L)*128(W)*108(H)mm


Reliable

IFCC calibratorNormalAbnormalNormalAbnormal
Mean HbA1c%5.49.65.39.2
CV (%)2.5%1.9%2.4%1.8%


Principle

The analyzer works based on the principle of boric acid affinity fluorescence quenching. The content of HbA1c is quantitatively detected by detecting the amount of fluorescent substance changing with the binding and quenching of HbA1c and fluorescent


Performance Parameters

  • Accuracy: Is tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Precision:Samples with a concentration of 4.0%-6.5% are detected, sample coefficient of variation (CV) of the test results is not more than 3%.
  • Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficientrof the test results should be no less than 0.9900.
  • Stability:Within 8 hours after the instrument is turned on and stable, the relative deviation of the test results is not more than ±3%.
  • Functions of the analyzer:The function of report output in English; Abnormal alarm function.

Attention

  • Analyzer shall be used under good grounding conditions.
  • A three-phase connector is provided for the power cord of the analyzer. When the power socket has a grounding function, the plug shall be inserted into the socket.
  • The installation location shall be free of the direct sunlight and dust.
  • There shall be a level and stable table top, and there shall be no strong magnetic field and vibration within

Certificate


China Whole Blood Sample POCT HbA1c Analyzer 2 Minutes Fully Automated Haematology Analyser supplier

Whole Blood Sample POCT HbA1c Analyzer 2 Minutes Fully Automated Haematology Analyser