Intended Use
Labnovation HbA1c Analyzer LD-100 POCT Analyzer is intended for the
percent determination of hemoglobin A1c (HbA1c) in human whole
blood which is a semi-automatic instrument used to analyze glycated
hemoglobin. LD-100 is small and light, it can be used to detect of
HbA1c in medical units at all levels. Fually Automatic system can
help the test half work with double results.
Specifications
Model | LD-100 |
Sample Type | Whole blood |
Sample Volume | 4ul |
Test Time | Less than 3 minutes |
Data storage | 7000 |
Method | Fluorescent Immunoturbidimetry |
Operating Type | 1-Step Operation, Fully automatic system |
Measurement Range | HbA1c 4.0~15%(NGSP Unit) eAG 68-385mg/dl(mmol/l) |
Operating Condition | Temperature:15~35℃ Humidity:15~80%R.H |
Storage Condition | Analyzer:10-60℃; Test kit: 2~8℃ |
Voltage | 12VDC-3.33A |
Analytical wave-length | 510nm and 580nm. |
Certification | NGSP, IFCC
|
Working Principles
HbA1c Analyzer uses the (borate affinity) fluorescent
immunoturbidimetry. Push a mixture containing a fluorescent borate
conjugate into an integrated test cup and mix to dissolve
sufficiently. The blood samples in the sample collector are then
pushed into the buffer and mixed to release the hemoglobin from the
red blood cells. The total concentration of hemoglobin depends on
the initial reduced fluorescence signal. Fluorescent borate
conjugates bind to glycosylated hemoglobin, and glycosylated
hemoglobin is determined by detecting the decrease of fluorescent
active ingredients. The percentage of glycosylated hemoglobin in
total hemoglobin can be determined.
Reliable
IFCC calibrator | Normal | Abnormal | Normal | Abnormal |
Mean HbA1c% | 5.4 | 9.6 | 5.3 | 9.2 |
CV (%) | 2.5% | 1.9% | 2.4% | 1.8% |
Performance
Glycated hemoglobin (HbA1c) is reported by default in IFCC units
(mmol/mol) and NGSP units (%).
The accuracy is tested with the reference material as samples, and
the relative deviation of the determination results of the analyzer
should be within the range of ±8%.
Samples with a concentration of 4.0%-6.5% are detected, and the
sample coefficient of variation (CV) of the test results is not
more than 3%.
In the range of 4%-16% of HbA1c, the linear correlation coefficient
r of the test results should be no less than 0.9900.
Within 8 hours after the instrument is turned on and stable, the
same normal sample is tested, and POCT HbA1c Analyzer V1.0 2 the
relative deviation of the test results is not more than ±3%.
Certificate
Attention
The HbA1c Analyzer meets the emission and immunity requirements
specified in the relevant Section of GB/T 18268.26, as shown in the
table below.
- Users have the responsibility to ensure the electromagnetic
compatibility environment of the equipment, so that the equipment
can work properly.
- It is recommended that the electromagnetic environment be evaluated
before the equipment is used.
Company Profile
Labnovation Technologies, Inc. is an original manufacturer
established in Shenzhen, China since 2001. We are dedicated in
developing and manufacturing IVD instruments and reagents including
HbA1c analyzer and reagents, rapid test reader & reagents,
hematology reagents, clinical chemistry reagents, electrolyte
reagents, wash solution and urine test reagents.
Labnovation products are developed in house, tested extensively in
clinics and passed strict quality controls. All of our products are
CE marked and approved by SFDA. In the past 15 years, our products
have been exported to 110 different countries and used in 8000
hospitals worldwide. We provide both ready-to-use final products
and bulk OEM reagents, including ready-to-use reagents,
concentrated, and powder.
With an investment of 10% of our annual sales into R&D, we
release new products every years. We win more and more domestic and international cooperation by
company reputation and products quality while we actively take part
in fairs like MEDICA,AACC, ARBA HEALTH and so on through which we
are well-known by the companies in this field.