Product Details
HbA1c Analyzer LD-100 POCT Excellent Correlation With HPLC Protable
Analyzer For HbA1c Test Use IFCC Certificated
Intended Use
- It is intended for the determination of percent hemoglobin A1c (HbA1c) in human whole blood.
- It is a semi-automatic instrument used to analyze glycated
hemoglobin.
- It can be used to detect of HbA1c in medical units at all
levels.And it's very protable to carry, you can testing HbA1c
anytime.
- It has fully automatic system just need one step operation then the
test will be start.
Specifications
Model | LD-100 |
Sample Type | Whole blood |
Sample Volume | 4ul |
Test Time | Less than 3 minutes |
Data storage | 7000 |
Method | Fluorescent Immunoturbidimetry |
Operating Type | 1-Step Operation, Fully automatic system |
Measurement Range | HbA1c 4.0~15%(NGSP Unit) eAG 68-385mg/dl(mmol/l) |
Operating Condition | Temperature:15~35℃ Humidity:15~80%R.H |
Storage Condition | Analyzer:10-60℃; Test kit: 2~8℃ |
Voltage | 12VDC-3.33A |
Analytical wave-length | 510nm and 580nm. |
Certification | NGSP, IFCC |
Principle
HbA1c Analyzer uses the (borate affinity) fluorescent
immunoturbidimetry. Push a mixture containing a fluorescent borate
conjugate into an integrated test cup and mix to dissolve
sufficiently.
Purpose
HbA1c Analyzer is used for the quantitative detection of
glycosylated hemoglobin (HbA1c) in venous blood in EDTA test tubes
based on the principle of boronic acid affinity fluorescence
quenching.
Prduct Feature
- Category of the test product: Laboratory
- Device category: Fixed
- Overvoltage category: Category II
- Working environment: Standard
- Power connection: Detachable power supply cord
- Power supply: AC
- Input power: <60VA
- Operating mode: Continuous
- Contamination Level: Level 2
- Net weight: ≤5kg
- Overall size: 192(L)×128(W)×108(H) mm
- Storage environment: Temperature: - 20 ~55 C; Humidity: 10%~93%;
Pressure: 75 kPa~106 kPa.
- Data storage: 7000
Reliable
IFCC calibrator | Normal | Abnormal | Normal | Abnormal |
Mean HbA1c% | 5.4 | 9.6 | 5.3 | 9.2 |
CV (%) | 2.5% | 1.9% | 2.4% | 1.8% |
Use Step
- Place cartridge in analyzer
- Push bead into reagents
- Insert sample into cartridge
Advantage
- Boronate Affinity Method
- CV<3%, Excellent Correlation With HPLC
- Battery Integrated,Portable,Compact
- Individually packaged reagents
- RFID For Batch Management
FAQ
- Is there a capillarys/minicap computer?
A: Yes , we have. The display is a minicap computer.
A: Yes, we have. LD-100 install the built-in printer.
- With electric shock protection system or not?
A: Yes. The instrument has been tested by safety regulations and EMC to
meet regulatory requirements.
Certificated
Company Profile
Labnovation Technologies, Inc. is an original manufacturer
established in Shenzhen, China since 2001. We are dedicated in
developing and manufacturing IVD instruments and reagents including
HbA1c analyzer and reagents, rapid test reader & reagents,
hematology reagents, clinical chemistry reagents, electrolyte
reagents, wash solution and urine test reagents.
Labnovation products are developed in house, tested extensively in
clinics and passed strict quality controls. All of our products are
CE marked and approved by SFDA. In the past 15 years, our products
have been exported to 110 different countries and used in 8000
hospitals worldwide. We provide both ready-to-use final products
and bulk OEM reagents, including ready-to-use reagents,
concentrated, and powder.
With an investment of 10% of our annual sales into R&D, we
release new products every years. We win more and more domestic and international cooperation by
company reputation and products quality while we actively take part
in fairs like MEDICA,AACC, ARBA HEALTH and so on through which we
are well-known by the companies in this field.