Product Details
HbA1c Analyzer LD-560 Labnovation Latest Analyzer For HbA1c Testing
HPLC Method Dual Mode For Operation
Intended Use
The Fully Automated HbA1c Analyzer is used in conjunction with
suitable reagents for the quantitative detection of glycosylated
hemoglobin (HbA1c) in human blood.
Specifications
Name | Fully Automated HbA1c Analyzer |
Model | LD-560 |
Method | HPLC |
Parameters | HbA1c, HbF, HbA1a, HbA1b, HbA0; HbA2 (optional) |
Test Speed | 90 seconds per test |
Wavelength | 420nm |
Sample Type | Whole Blood, Pre-diluted blood |
Autoloader Capacity | 20 tubes |
Reagents Kit | Eluent A, Eluen B, Hemolysis, Chromatography Column |
Precision | CV<2% |
Column Capacity | 3000 tests |
Report Range | 3-18% |
Working Condition | Temperature: 15-30℃ |
Dimensions | 378mm×380mm×510mm |
Advantage
- HPLC: The most recognized principle for HbA1c testing, CV<2%.
- Full Automation: Autoloader for 20 tubes, Automatically recognizing sample type,
and switching the testing mode,
- Just one click to start testing.
- Smart System: Robust computing system, Automatic scanning of barcode, Automatic
sample type recognition, Reagents level alarm.
- Quality & Performance: IFCC and NGSP certification, Control & Calibrators from the
original manufacturer
- Convenient Operation: Auto washing for self maintenance at startup, 10" LCD touch
screen to provide rich information, Easy to change reagents.
Reagents and Consumables
- Eluent A/Eluent B/Eluent C: Adjusts the pH of the solution for the elution of glycosylated
hemoglobin and non-glycated hemoglobin.
- Hemolysis Reagent: Used to dissolve red blood cells and release hemoglobin.
- Chromatography column: Used for separation and elution of glycosylated hemoglobin and
non-glycated hemoglobin.
- Filter: Used to initially filter the sample after hemolysis.
- Paper Rolls: Prints a report of the test results.
Operation Preparation
Before operating this analyzer, please read the operation manual
carefully to avoid malfunction or damage.
If the analyzer is used in a manner not specified by the
manufacturer, the protection provided by the analyzer may be
destroyed.
Before turning on the analyzer, the operator must check the
following requirements to ensure that the system is ready.
(1) Check the remaining amount of reagents
Check whether the remaining amount of eluent A, eluent B, eluent C
and hemolysis agent is sufficient.
(2) Check the waste liquid barrel
Check whether the waste liquid barrel has been emptied before
starting the analyzer every day.
(3) Check the liquid tubes and power supply
Check whether the tubes of reagent and waste liquid are bent and
whether the connections are reliable.
Check the analyzer for fluid leakage.
Check whether the power plug of the analyzer is securely inserted
into the power socket.
(4) Check the printer
Check whether the paper roll is sufficient and whether it is
installed in correct place.
Certificated Display
Company Profile
Labnovation Technologies, Inc. is an original manufacturer
established in Shenzhen, China since 2001. We are dedicated in
developing and manufacturing IVD instruments and reagents including
HbA1c analyzer and reagents, rapid test reader & reagents,
hematology reagents, clinical chemistry reagents, electrolyte
reagents, wash solution and urine test reagents.
Labnovation products are developed in house, tested extensively in
clinics and passed strict quality controls. All of our products are
CE marked and approved by SFDA. In the past 15 years, our products
have been exported to 110 different countries and used in 8000
hospitals worldwide. We provide both ready-to-use final products
and bulk OEM reagents, including ready-to-use reagents,
concentrated, and powder.
With an investment of 10% of our annual sales into R&D, we
release new products every years. We win more and more domestic and international cooperation by
company reputation and products quality while we actively take part
in fairs like MEDICA,AACC, ARBA HEALTH and so on through which we
are well-known by the companies in this field.