Product Details
Rapid Antigen Test Kit CoV-19 Antigen Saliva Rapid Test Kit High
Specificity 20 Tests Professional Use Rapid Test Kit
Intend Use
SARS-CoV-2 Antigen Saliva Rapid Test Kit is intended for the
qualitative detection of SARS-CoV-2 antigen in human saliva sample.
The test result can be used for early triage and rapid management
of suspected populations. But the test kit cannot be used as
diagnosis basis of SARS-CoV-2 infection. Further nucleic acid
detection should be carried out for suspected population whose
antigen test result is positive or negative.
Product Details
Item | Value |
Name | SARS-CoV-2 Antigen Saliva Rapid Test Kit |
Model Number | LX-401603 |
Type | 20 Tests/Kit |
Warranty | 18 Months |
Quality Certification | CE, MSDS |
Safty Standard | ISO13485 |
Sample Type | Saliva |
Sample volume | 3 Full drops |
Test Speed | Within 10-15 minutes |
Specificity | 99.00% |
Sensitivity | 94.29% |
Total Accuracy | >95% |
Product Feature
- High Accuracy, Specificity and Sensitivity
- Test Results within 10-15 mins
- Room Temperature Storage
- Saliva Swab Available
- One Step Operation
Storage And Expiry
Store as packaged in the sealed pouch at 2-30℃, avoid heat and
sunshine, dry place, valid for 24 months. Do not freeze. Do not
open the inner packaging until ready, it must be used within one
hour if opened (Humidity≤60%, Temp: 20℃-30℃). Please use
immediately when the humidity>60%.
Main Components
- 20 Test Cassettes
- 20 Saliva Collectors With Collection Tubes
- 20 Sample Extraction Buffer
- 1 Tube stand
- 1 Instruction For Use
Use Step
- Open the cap of the collection tube and istall saliva collector.
- Put the collection tube with saliva collector close to lips and let
the saliva flow into the collection tube. Tje volum of saliva needs
to be half of 0.5 scal mark(0.25).
- Screw the sample extraction buffer carefully.
- Add all sample extration buffer to the collection tube. Discard the
saliva collector, tighten the cap onto the specimen collection
tube.
- Shake the specimen collection tube at least three time vigorously
to mix the saliva and the extraction buffer. Squeeze bottom of the
collection tube ensure the saliva is thoroughly mixed.
- Add 3 full drops of the solution to the sample well(S). Read the
result at 15 minutes. Do not interpret the result after 20 minutes.
Result Interpretation
POSITIVE: Two (2) distinct colored lines appear. One line should be in the
control region (C) and the other line should be in the test region
(T).
NEGATIVE: One (1) colored line appears in the control region(C). No apparent
colored line appears in the test region (T). The negative result
does not indicate the absence of analytes in the sample, it only
indicates the level of tested analytes in the sample is less than
the minimum detection limit.
INVALID: No colored lines appear, or control line fails to appear,
indicating that the operator error or reagent failure. Verify the
test procedure and repeat the test with a new testing device.
Virus Sources
Global high frequency mutation | Alpha / B.1.1.7(U.K.) | Beta I B.1.351(South Africa) |
Gemma I P.1(Brazil) | Kappa I B.1.617.1(India) | Delta I B.1.617.2(India) |
C.37,ect | Alpha I B.1.17(U.K.) | B.1.36.16.etc |
A.2.5,etc | A.23.1 | Alpha I B.1.17(U.K.) |
B.1.1.33.etc | C.1.1.etc. | etc. |
Certificate
Precaution
- Components in different batch should not be mixed; Viral Transport
Media (VTM) may affect the test result; extracted specimens for PCR
tests cannot be used for the test.
- If the saliva is not well mixed in the sample extraction tube,
false negative results may occur.
- Keep away from children. Any child under age 13 shouldn’t perform
the test without parental guidance, or professional aid.
- The extraction reagent contains preservative agent which may be
toxic if ingested. When disposed of through a sink, flush with a
large volume of water.
FAQ
We have the MOQ limit, which is 10000 pieces.
Air Cargo, Ocean Cargo or by Express
Business to Business account
Whatsapp, E-mail or Phone.
After order confirmed, we will arrange your order immediately,and
offer you an estimated delivery date.
Company Profile
Labnovation Technologies, Inc. is an original manufacturer
established in Shenzhen, China since 2001. We are dedicated in
developing and manufacturing IVD instruments and reagents including
HbA1c analyzer and reagents, rapid test reader & reagents,
hematology reagents, clinical chemistry reagents, electrolyte
reagents, wash solution and urine test reagents.
Labnovation products are developed in house, tested extensively in
clinics and passed strict quality controls. All of our products are
CE marked and approved by SFDA. In the past 15 years, our products
have been exported to 110 different countries and used in 8000
hospitals worldwide. We provide both ready-to-use final products
and bulk OEM reagents, including ready-to-use reagents,
concentrated, and powder.
With an investment of 10% of our annual sales into R&D, we
release new products every years. We win more and more domestic and international cooperation by
company reputation and products quality while we actively take part
in fairs like MEDICA,AACC, ARBA HEALTH and so on through which we
are well-known by the companies in this field.