Product Details
Hematology Analyzer Reagents Horiba Abx Hematology Reagent For
Pentra120 Analyzers
Intended Use
To be used for blood cell counting, sizing, and WBC
differentiation, hemoglobin determination on ABX PENTRA120
hematology analyzers. This product is for In Vitro Diagnostic Use
only.
APPLICABLE INSTUMENT
For use with Pentra120 hematology analyzers.
Specification
L-0901020 | Diluent-P | 20L |
L-0206010 | EO-Lyse | 1L |
L-0902010 | α-Lyse | 1L |
L-0204050 | BA-Lyse | 5L |
L-0903010 | Cleaner-P | 1L |
L-0401005 | Cleaner-C | 500ml |
KIT COMPOSITION
BA-Lyse | Hydrochloric Acid <0.01%, Surfactant<0.05% |
EO-Lyse | Sodium Chloride <1.00%, Formic Dye <0.005% |
α-Lyse | Quaternary Ammonium Salt<6.0% |
Diluent-P | NaCl≤9.4%, Buffer≤1.6%, Anti-Microbial Agent≤1.0% |
Cleaner-P | Buffer<0.2%, Proteolytic Enzyme<0.3% |
Cleaner-C | Sodium Hypochlorite |
Procedures
- From the run screen, press “ESC” to access the “MAIN MENU.
- Remove the Diluent Line from the Diluent box.
- Wipe the tube’s surface with a lent free tissue, and then rinse
with distilled water.
- Place the tubes on a dry clean place.
- Using the arrow keys to select the menu “3-Reagents” and press
“Enter”
- From the Reagents menu, using the arrow keys to select the menu
“3-Prime” and press “1-Diluent”. This step will purge the diluent
lines with air to make sure that the reagents will not be mixed
with the previously used ones. At this step an error message
appears: “Error: NO Diluent, Check Level”
- Press “ESC”. At this step an error message appears: “Emergency
stop, Run an autocontrol”
- Press “ESC” three times to access the Main Menu.
- Press “4-Maintanence” – “1-Autocontrol cycle”. After the cycle has
been done, press “ESC”.
- Press “3-Reagents” – “3-Prime”
- Remove all the lines from the bottles Cleaner, Eosinofix, Basolyse
II, and Alphalyse.
- Press “2-Cleaner”. This step will purge the Cleaner lines with air.
- Press “3-Eosinofix”. This step will purge the Eosinofix lines with
air.
- Press “4- Basolyse II”. This step will purge the Basolyse lines
with air.
- Press “5-Alphalyse”. This step will purge the Alphalyse lines with
air.
- Wipe the tube’s surface with a lent free tissue, and then rinse
with distilled water.
- Put all five reagent aspiration tubes into the appropriate
Labnovation box and bottles.
- Press “ESC” – “1-Level Change” – “All reagents” This step will set
all reagent levels to full (100%), and an autoprime cycle will be
done.
- Press “ESC” – “Prime” – “All reagents”. Repeat this step once
again.
- After all three prime cycles have been done, press “ESC” key three
times, to access the “Start Cycle” menu.
- Run at least 5 backgrounds. Check for the acceptable values.
- Run all three levels of a dedicated commercial control. Check for
the acceptable values.
- Recalibrate the unit if necessary. The default pathword for ABX
Pentra 60 users is “123”.
Advantage
- One source for all brands of analyzer
- Reagents for both 3-parts and 5-parts
- Ready-to-use final products and bulk OEM reagents
- ISQ13485:2003 and ISO9001:2008 certified
- CE marked, FDA cleared
- Well-established brand used by thousands of lab in 95 countries
- High quality, high performance and high fidelity of correlations
with original brand
Storage
Store the product at 5-35℃ in a dust free place with good
ventilation. Temperature outside the range may damage the product.
The open vial life of the product is 30/60 days. Unused reagents
should be discarded after 30/60 days. Do not mix residual with a
new carton.
L-0901020 | Diluent-P | 24 months |
L-0206010 | EO-Lyse | 18 months |
L-0902010 | α-Lyse | 24 months |
L-0204050 | BA-Lyse | 24 months |
L-0903010 | Cleaner-P | 18 months |
L-0401005 | Cleaner-C | 12 months |
PRECAUTIONS
- Re-calibration is recommended when changing the origin of the
reagents.
- It is not recommended using different brands of solutions together
on one unit of analyzer.
- Do not ingest. Avoid contact with skin and eyes.
- Skin contact: Flush with plenty of water.
- Eyes contact: Flush with plenty of water. Obtain immediate medical
attention.
- This kit is for professionals and in vitro diagnostic use only.
FAQ
We have the limit order which is 10000, we would like to cooperate
with you, don't worry about MOQ, just send us of your what items
you want order.
Stock 3-7 days in general. Or please contact us by email for
specific lead time base on your order quantities.
Yes, we accept both OEM and ODM for customers.
- What are your terms of delivery?
We can accept EXW, FOB, CIF, etc. You can choose one which is the
most convenient for you.
- Manufacturer or Trade Company?
We're Manufacturer.
Company Profile
Labnovation Technologies, Inc. is an original manufacturer
established in Shenzhen, China since 2001. We are dedicated in
developing and manufacturing IVD instruments and reagents including
HbA1c analyzer and reagents, rapid test reader & reagents,
hematology reagents, clinical chemistry reagents, electrolyte
reagents, wash solution and urine test reagents.
Labnovation products are developed in house, tested extensively in
clinics and passed strict quality controls. All of our products are
CE marked and approved by SFDA. In the past 15 years, our products
have been exported to 110 different countries and used in 8000
hospitals worldwide. We provide both ready-to-use final products
and bulk OEM reagents, including ready-to-use reagents,
concentrated, and powder.
With an investment of 10% of our annual sales into R&D, we
release new products every years. We win more and more domestic and international cooperation by
company reputation and products quality while we actively take part
in fairs like MEDICA,AACC, ARBA HEALTH and so on through which we
are well-known by the companies in this field.