HbA1c Test Analyzer LD-100 Hemoglobin Testing Analyzer POCT One-Step HbA1c Testing Analyzer

Intended Use

LD-100 POCT HbA1c Analyzer is intended for the percent determination of hemoglobin A1c (HbA1c) in human whole blood. Which is a semi-automatic instrument used to analyze glycated hemoglobin and it's suitable for the detection of HbA1c in medical units at all levels.

Specifications

ModelLD-100
MethodFluorescent Immunoturbidimetry
Operating TypeOne-Step, fully automatic
Measurement Time< 3 minutes
Sample TypeWhole blood
Sample Volume4ul
Data storage7000
Weight800gs
Measurement RangeHbA1c 4.0~15%(NGSP Unit)
eAG 68-385mg/dl(mmol/l)
Operating ConditionTemperature:15~35℃
Humidity:15~80%R.H
Storage ConditionAnalyzer:10-60℃; Test kit: 2~8℃
Power connectionDetachable power supply cord


PRINCIPLE

  • Uses the (borate affinity) fluorescent immunoturbidimetry
  • Push a mixture containing a fluorescent borate conjugate into an integrated test cup and mix to dissolve sufficiently.
  • The blood samples in the sample collector are then pushed into the buffer and mixed to release the hemoglobin from the red blood cells.
  • The total concentration of hemoglobin depends on the initial reduced fluorescence signal.
  • Fluorescent borate conjugates bind to glycosylated hemoglobin, and glycosylated hemoglobin is determined by detecting the decrease of fluorescent active ingredients.
  • The percentage of glycosylated hemoglobin in total hemoglobin can be determined.

Feature

  • Simple Operation Step, One-Step Testing Process
  • Protable, Light and Small,Easy to carry
  • Fast test speed,Quick Recation
  • Battery Integrated
  • NGSP And IFCC Certificated
  • Cv<3%, Excellent Correlation With HPLC
  • RFID For Batch Management
  • Color Touch Screen, Easy To Read

Reliable

IFCC calibratorNormalAbnormalNormalAbnormal
Mean HbA1c%5.49.65.39.2
CV (%)2.5%1.9%2.4%1.8%

Use Step

  • Place cartridge in analyzer
  • Push bead into reagents
  • Insert sample into cartridge


Performance Parameters

  • Accuracy: tested with the reference material as samples, and the relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Precision: Samples with a concentration of 4.0%-6.5% are detected, and the sample coefficient of variation (CV) of the test results is not more than 3%.
  • Appearance:All fasteners should not be loosened. Various adjusting elements can rotate flexibly and function normally. Readouts should be clear on the display screen.
  • Linearity:In the range of 4%-16% of HbA1c, the linear correlation coefficient r of the test results should be no less than 0.9900.
  • Stability:Within 8 hours after the instrument is turned on and stable, the same normal sample is tested, and the relative deviation of the test results is not more than ±3%.
  • Permission: The authority is the first-level authority, and the login authority is the first-level authority.