POCT One Step HbA1c Testing Analyzer Whole Blood Hemoglobin Analyzer LD-100

Brand Name:LABNOVATION
Certification:IFCC, NGSP, CE
Model Number:LD-100
Minimum Order Quantity:1
Delivery Time:10 work day
Payment Terms:D/A, D/P, T/T
Contact Now

Add to Cart

Active Member
Location: Shenzhen China
Address: 101 and 5th Floor, Building 1, No. 68,18th Road, Guangming Hi-Tech Park, Tangjia Community, Fenghuang Street, Guangming District, Shenzhen 518107 ,China
Supplier`s last login times: within 29 hours
Product Details Company Profile
Product Details

HbA1c Analyzer POCT One Step HbA1c Testing Analyzer LD-100 Hemoglobin Analyzer


Product application

This instrument is intended for the percent determination of hemoglobin A1c (HbA1c) in human whole blood.

Specifications

ModelLD-100
MethodBoronate Affinity
Operating Type1-Step, fully automatic
Measurement TimeLess than 3 minutes
Sample TypeWhole blood
Measurement RangeHbA1c 4.0~15%(NGSP Unit)
eAG 68-385mg/dl(mmol/l)
Operating ConditionTemperature:15~35℃
Humidity:15~80%R.H
Dimensions220(w)x150(L)x120(H)mm
Shelf-Life of Test Kit9 months
Weight800gs
Storage ConditionAnalyzer:10-60℃; Test kit: 2~8℃
Voltage12VDC-3.33A

PRINCIPLE

HbA1c Analyzer uses the (borate affinity) fluorescent immunoturbidimetry. Push a mixture containing a fluorescent borate conjugate into an integrated test cup and mix to dissolve sufficiently. The blood samples in the sample collector are then pushed into the buffer and mixed to release the hemoglobin from the red blood cells. The total concentration of hemoglobin depends on the initial reduced fluorescence signal. Fluorescent borate conjugates bind to glycosylated hemoglobin, and glycosylated hemoglobin is determined by detecting the decrease of fluorescent active ingredients. The percentage of glycosylated hemoglobin in total hemoglobin can be determined


Performance Indicators

  • Result reporting unit: Glycated hemoglobin (HbA1c) is reported by default in IFCC units (mmol/mol) and NGSP units (%).
  • Accuracy: The relative deviation of the determination results of the analyzer should be within the range of ±8%.
  • Precision: Samples with a concentration of 4.0%-6.5% are detected, and the sample coefficient of variation (CV) of the test results is not more than 3%.
  • Linearity: In the range of 4%-16% of HbA1c, the linear correlation coefficient r of the test results should be no less than 0.9900.

Feature

  • One-step Operation
  • Battery Integrated
  • Portable, Compact
  • RFID For Batch Management
  • Color touch screen
  • External printer (Blue-tooth)
  • USB Port, LIS Support

Reliable

IFCC calibratorNormalAbnormalNormalAbnormal
Mean HbA1c%5.49.65.39.2
CV (%)2.5%1.9%2.4%1.8%

Use Step

  • Place cartridge in analyzer
  • Push bead into reagents
  • Insert sample into cartridge