Add to Cart
Basic parameters:
Brand Name: | Rainbow |
Size: | 12.1 inch touch screen |
Model: | PM-9000A |
Functions: | ECG, Heart rate, oxygen saturation, NIBP,TEMP,RESP |
Manufacturer: | Hunan Rainbow Technology, Ltd. |
Features:
1. Brand-new model design, combines Chinese classical elegance and
European style.
2. Modularized and one-piece design,strong anti-interference
capability, more stable functions,consumes less power.
3. High brightness and resolution 12.1-inch colorful TFT LCD
display touch screen.
4. Built-in battery,standby time to 120 minus,AC/DC power
conversion.
5. Unique Battery charge detection,displayable battery level.
6. Unique real person voice alarm,sound, light and word
alarm,three-level intelligent alarm
7. Applying “15-350BP”wide-range heart rate measurement design
according to features of newborns.
8. Applying“Double Overvoltage protection” to ensure the safety,
consistency and accuracy under all conditions.
9. Blood pressure with new anti-movement,low perfusion measurement
technology in order to guarantee the newborn measurement accuracy
10. Chinese, English, French, Russian, Portuguese, Turkish and
other languages.
11. Personalized operation system,concise and straightforward
12. Various interfaces: A single guide, standard, large font, all
leads to satisfy clinical needs
13. All leads, seven-channel synchronous ECG display
14. More powerful anti-movement capability in blood pressure
measurement, more precise measurement towards low perfusion and
shaking fingers.
15. 2000-piece trend and data storage,200-set alarm events available
for printing
16. Anti-movement-interference to minimize failures and adjustable
for low or high pulse measurement.
17. New improvements in UI operation of the monitor software with
larger and clearer icons
18. Monitor software with more shortcuts and “one-step” menu
management, more straightforward.
19. Operational parameter functions such as CO2 and IBP can be
realized with plug and play.
20. Different interface can be set in different clinical
departments
21. Powerful analysis software function: pacemaker analysis,ST
segment analysis, arrhythmia analysis, drug concentration level
measurement, titrimeter to ensure quick access to all information
for clinic decisions.
22. Suitable for emergency room, operating room, PACU, ICU and CCU
23. Used for adults, children, and newborns
24. Strictly design and manufacture on the basis of CE standard for
the basic safety, stability and durability.
25. Standard of the Ethernet protocols, supports for wired or
wireless connection, central monitoring system can be composed of
up to 64 monitors with online upgrading software.
26. Strong defibrillation protection, anti high frequency and
muscle electricity for accurate measurement results.
Standard configuration:PM-9000A multi parameter patient monitor×1 set, standard 5-leads
ECG conductance joint connecting cables×1 set, standard adult blood
pressure cuffs×1 set, adult SPO2 probe×1 set, TEMP probe×1 set,
power plug line×1 set, grounding wire×1 set, English operation
manual×1 set, three certificates×1 set.
Optional::three-channel thermal printer, monitor cart / support bracket/rack
Children/newborn SPO2 probe,Children/newborn blood pressure cuffs
Technical parameters:
Lead mode;I,II,III,AVR,AVL,AVF,V1-6
Gain: ×0.25, × 0. 5, and × 1, × 2
Frequency: 0.5 Hz - 100 Hz
Common-mode signal inhibition: More than 70 dB
Scan rate: 12.5 mm / S, 25 mm / S, 50 mm / S standard three stalls.
HR: ± 5 BPM
Precision calibration signal: 1mv(peak, ± 3% accuracy)
ST Detection: measurement range (-2.0mV----+2.0mV)
Using Standard: meet the ANSI / AMI EC13 -2002 standard
Response time: 1s
Alarm: Sound and Light
Preset heart rate range: (Alarm over preset numerical)
Ceiling: 1-255 bpm adjustable
Threshold: 0-254 bpm adjustable
Technology: Oscillography
Measurement method:more accurate with reverse measurement
Measurement units:mmHg/Kpa
Overvoltage protection:double safety protection
Measure time:less than 45S
Scope: Pressure Cuffs 0-250 mmHg
Measure accuracy:ANSI/AAMI SP10-2002 standard average accuracy and deviation
Inflatable cuffs: 180 mmHg (120mmHg for children
Inflatable cuffs follow: original SBP: + 30 mmHg
Measuring range:
SBP 60 mmHg~250 mmHg
Pmean 45 mmHg~235 mmHg
DBP 40 mmHg~220 mmHg
Measure accuracy:±1.1KPa(±8mmHg)±10%
Response time: 1s
Alarm: Sound and Light
Preset range: report (Numerical exceed preset alarm)
SBP maximum 1mmHg~255 mmHg
Threshold 0 mmHg~254 mmHg
DBP maximum 1mmHg~255 mmHg
Threshold 0 mmHg~254 mmHg
Alarm accuracy:±1 mmHg
Standard: ANSI/AAMI SP10-2002
Range: 0-100%
Accuracy: 1%
Resolution: 1%
Pulse frequency: 20-250 times / min
Response time: 1s
Alarm: Sound and Light
Preset range: (report Alarm over preset numerical)
Ceiling: 1% - 100% adjustable
Threshold: 0% - 99% adjustable
Technology: thermostat temperature probe
Measuring range: 20 ° C-45 ° C
Temperature resolution: 0.1%
Accuracy: ± 1 ° C
Response time: 1s
Alarm: Sound and Light
Preset range: report (numerical preset alarm over)
Maximum: 20.1 ° C-45.5 ° C adjustable
Threshold: 20 ° C-45.4 ° C Adjustable
Alarm accuracy:±1℃
Breathing frequency range: 0-60 bum
Accuracy: ± 1rpm
Response time: 1s
Gains options: × 1, × 2, × 0.5, and × 0.25 four trenches
Alarm: Sound and Light
Ceiling: 10-100 bpm adjustable
Threshold: 0 -99 bpm adjustable
Alarm accuracy:±1rpm
Specification:three-channel thermal recorder
Screen:12.1 inches TFT screen of LCD
Battery: sealed maintenance-free lithium battery
Safety standard: lec601-1(GB9706.1)