Customized Antspace HK3 Mining Farm with Liquid Cooling Container

Brand Name:Bitmain
Certification:CE
Model Number:HK3
Minimum Order Quantity:1 Antspace
Payment Terms:usdt/usdc/tt
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: 2nd Floor,No.5 Building,Dongwu Industrial Park,Donghuan 1st Road,Longhua New District, Shenzhen, Guangdong Province
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Customized Antspace HK3 Mining Farm With Liquid Cooling Container


Specification Details For ANTSPACE HK3

Product Overview
ModelANTSPACE HK3
Dimensions (L*W*H) (mm)6058*2438*2896
Miner Capacity210 units -S19 Hyd. Series miner
Container CertificationChina Classification Society Certification
Safety CertificationNorth America/Standards:NFPA 79:2021,UL 508A:2018 R8.21,
CSA C22.2 No. 14-18,ANSI/ISO 12100:2012
EU/Standards:EN ISO 12100,EN 60204-1
Operating Power(kW)1047~1050
PUE(Power Usage Effectiveness)1.022(Excluding cooling tower)/1.036(Including cooling tower)
Input Voltage and Frequency415V±5% 60Hz(North America)
400V±5% 50Hz(EU,Middle East)
Detailed Characteristics
Shipping Weight(T)8
Operating Weight (T)12
Main Switch of Power Distribution Cabinets(A)1200(North America)
1250(EU,Middle East)
Rated Current(A)952
Standard Power(kW)1049
Maximum Power(kW)1050
Rated Current per Miner(A)10
Inlet CableThe inlet cables can withstand high-voltage of above 600V, with the following requirements per phase:
L1 single core cable 600kcMil(300mm²)x4
L2 single core cable 600kcMil(300mm²)x4
L3 single core cable 600kcMil(300mm²)x4
N Single-core cable 600kcMil(300mm²)x4
PE single-core cable 500kcMil(240mm²)x2
Connection Interface(Cooling Tower)DN125(GB/T 9119-2010 PN16 DN125)
Connection Interface(Plate Heat Exchage Interface)DN100(GB/T 9119-2010 PN16 DN100)
Flow Rate(m³/h)>85
Quantity of ANTSPACE powered by one 2500kVA Transformer2

Specification Details For Dry-Wet Towers

One of the following two Dry-Wet Towers can be chosen based on the personalized demand.

Product Overview
TypeDry-Wet Tower Traditional Type (DWT-T)Dry-Wet Tower Container Type (DWT-C)
Dimensions(L*W*H)(mm)5800*2240*42006058*2438*2896
Heat Dissipation Capacity(kW)10001000
Outlet Temperature @ 28℃ Wet Bulb Temperature35℃35℃
Container CertificationNoneChina Classification Society Certification
Safety CertificationNorth America/Standards: NFPA 79:2021, UL 508A:2018 R8.21,
CSA C22.2 No. 14-18, ANSI/ISO 12100:2012
EU Standards: EN ISO 12100, EN 60204-1
North America/Standards: NFPA 79:2021, UL 508A:2018 R8.21,
CSA C22.2 No. 14-18, ANSI/ISO 12100:2012
EU Standards: EN ISO 12100, EN 60204-1
Operating Power(kW)14~2814~28
Motor Rated Voltage and Frequency415V±5% 60Hz(North America)
400V±5% 50Hz(EU,Middle East)
415V±5% 60Hz(North America)
400V±5% 50Hz(EU,Middle East)
Detailed Characteristics
Shipping Weight(T)57
Operating Weight(T)912
Connection Interface(Container)DN125(GB/T 9119-2010 PN16 DN125)DN125(GB/T 9119-2010 PN16 DN125)
Water Resupply Pipe InterfaceDN40(Internal thread)DN40(Internal thread)
Drain Pipe InterfaceDN65(Internal thread)DN65(Internal thread)
Noise Level @25℃, 16m70dBA70dBA
Water Consumption(m³/h)1~1.51~1.5

| Environmental Requirementss



Environmental Requirements
1Cooling tower is required to be placed on flat ground, horizontal degree (±1 degree).
2The ground surfaced is required to be hardened and stable, able to withstand at least 14-ton load.
3A 10-ton crane is needed for unloading ANTSPACE and cooling tower.
4Add-on items such as stairs, transformers, cables, bridge racks and cable distribution boxes are not included in the delivery of ANTSPACE. BITMAIN team can provide design suggestions if needed.
5Client needs to confirm the opening directon of container and it needs to face air-intake. Door on left is current design by defult.
6Keep at least 2 meters of air in-take space around the cooling tower.
7Altitude: ≤3000m. If the altitude is higher than 1000-meter, transformer and switch should be derated, the total power of ANTSPACE must be decreased by 1% for each elevation increment of 100 meters.
8Operating temperature: -25°C to 40°C. Operating humidity: 10%RH to 90%RH. When the initial coolant temperature is below 20 °C, the internal circulation should be turned on to heat up the coolant to above 20 °C before starting the mining machine.
9When the ambient temperature is below 5 ℃, the cooling tower can be switched to cold-dry mode.
10Choose pure water or suitable antifreeze as coolant based on local climate conditions.
11The suitable ambient temperature for ANTSPACE does not represent the suitable ambient temperature for mining machine.