Frequency Inverter AC Drive PG Card Closed Loop Vector Control VFD Accessories

Brand Name:CHIFON
Certification:CE, ISO9001, SGS, EAC
Model Number:PG2
Minimum Order Quantity:1pcs
Delivery Time:sample order 2 working days, bulk order 7-10 working days
Payment Terms:L/C, T/T, Paypal
Contact Now

Add to Cart

Active Member
Location: Hangzhou Zhejiang China
Address: No. 25 Xianxing Rd, Xianlin Industrial Park, Hangzhou, Zhejiang, China
Supplier`s last login times: within 26 hours
Product Details Company Profile
Product Details

Closed-loop Vector Control Frequency Inverter AC Drive With PG Card



►Products Overview

This product is suitable for FPR500A, FPR500E series inverters equipped with asynchronous motors, or synchronous motors equipped with ABZ incremental encoder.


A. Technical specifications

Input power: 24V/200mA (provided by the control board)

Output power: 5V/200mA or 15V/100mA

Installation environment: indoor, no dust, corrosive gas, combustible gas, oil, water vapor, etc.

Ambient temperature: -10°C ~ +50°C

Environmental humidity: less than 95%RH, no condensation

Vibration: less than 0.6G


B. Terminal function


DefinitionFunction instruction
A+Encoder input differential signal A
A-
B+Encoder input differential signal B
B-
Z+Encoder input differential signal Z
Z-
VCCOutput power supply
GNDOutput power supply
PEGround terminal


Output power jumper wire selection: through the transformation of JP1, select the VCC output voltage as 5V or 15V

3. Installation and wiring:

Differential output encoder wiring method: connect the signal line and power line correspondingly, pay attention to the work voltage of the encoder.

Wiring method of open-drain NPN output encoder: signal wire ABZ is connected to A-, B- and Z- correspondingly.

4. Debugging method After installation and wiring, select the correct working voltage according to the parameters on the encoder nameplate (VCC output 5V Or 15V).

After the inverter is powered on, set the parameters for debugging as follows:

1. Modify the F0-01 control mode to 1 (with PG vector control).

2. Modify the number of encoder lines F1-27 (there are instructions on the encoder).

3. When the motor is no-load, select parameter auto-tuning F1-37 option 2 to start motor parameter auto-tuning.

5. EMC Guidance

  1. During on-site installation and commissioning, the signal line and power line need to be routed in different troughs. Encoders lines are strictly prohibited to bundle with the power cables and route them together, otherwise the encoder interference problem is prone to occur.
  2. The motor shell must be connected to the ground terminal (PE terminal) of the inverter, and the ground line on the side of the motor shell must be well connected; otherwise, a good grounding effect will not be achieved.
  3. It is recommended to use twisted-pair cables. For differential encoders, twisted-pair cables must be wired as differential pairs.

The shielding layer is connected to the ground terminal (PE terminal) of the inverter. 4. For some large-scale equipment, the inverter is far away from the motor, and the motor cable length is greater than 10 meters.

The grounding effect will be worse due to the influence of inductance. In this case, the shielding layer of the encoder can be disconnected from the grounding terminal of the inverter.





China Frequency Inverter AC Drive PG Card Closed Loop Vector Control VFD Accessories supplier

Frequency Inverter AC Drive PG Card Closed Loop Vector Control VFD Accessories

Inquiry Cart 0