What is a gas heat pump air conditioner?
Kingway 65KW Gas Heat Pump ( GHP )Air Conditioner
The gas heat pump air conditioner is an air conditioning unit that
drives the compressor through a gas engine
and circulates the gas heat pump for cooling or heating.
The difference between the gas heat pump air unit and the air
source heat pump air conditioner is: the gas V
heat pump air conditioner uses the TN city gas as the energy source: the air source heat pump air conditioner
is driven by the built-in motor of the compressor, driven by the gas engine, and uses the gas as the energy
source: the work uses electricity as the energy source .Self-developed GHP special gas engine.
Model | KW40NHCSW-1/1A | KW65NHCSW-1/2A | KW71NHCSW-1/2A | KW120NHSW-1/2A | |||
Power supply | 1N~220V 50Hz | 1N~220V 50Hz | 1N~220V 50Hz | 1N~220V 50Hz | |||
Performance | Nominal cooling capacity(KW) | 40 | 65 | 71 | - | ||
Refrigeration condition heat recovery (KW) | 23 | 37 | 40 | - | |||
Heating Capacity | Nominal Capacity (KW) | 45 | 73 | 80 | 120 | ||
Low Temperature (KW) | 45 | 73 | 80 | 120 | |||
Gas consumption (low calorific value) | Gas type | Natural gas | Natural gas | Natural gas | Natural gas | ||
Nominal cooling (KW) | 33.7 | 54.8 | 59.9 | - | |||
Nominal heating (KW) | 33.9 | 55.1 | 60.2 | 65 | |||
Electrical Characteristics | Refrigeration | Running current (A) | 4.68 | 7.60 | 8.30 | - | |
Power consumption (KW) | 0.95 | 1.54 | 1.68 | - | |||
Heating | Running current (A) | 4.39 | 7.14 | 7.80 | 12 | ||
Power consumption (KW) | 0.88 | 1.44 | 1.57 | 2.1 | |||
Water flow | Refrigeration (M3/h) | 6.88 | 11.18 | 12.21 | - | ||
Heating (M3/h) | 6.88 | 11.18 | 12.21 | 20.64 | |||
Domestic hot water (M3/h) | 3.88 | 6.30 | 6.88 | - | |||
Compressor | Type | Vortex *1 | Vortex *2 | Vortex *2 | Vortex *2 | ||
Displacement | 86.2 | 86.2 | 86.2 | 86.2 | |||
Lubricant grade (Cm3/rev) | FVC68D | FVC68D | FVC68D | FVC68D | |||
Refrigerator oil charge (L) | 2*1 | 2*2 | 2*2 | 2*2 | |||
Crankshaft heating belt (W) | 40*1 | 40*2 | 40*2 | 40*2 | |||
Engine | Range of rotation (RPM) | 1000~2300 | 1000~2300 | 1000~2300 | 1000~2300 | ||
Displacement (cc) | 2300 | 2300 | 2300 | 2300 | |||
Engine oil grade | 5W-40 | 5W-40 | 5W-40 | 5W-40 | |||
Lubricating oil charge (L) | 23 | 45 | 45 | 45 | |||
Start method | DC Electric Start | DC Electric Start | DC Electric Start | DC Electric Start | |||
Engine cooling water | Pump power (W) | 152 | 252 | 252 | 252 | ||
Charge (L) | 20 | 32 | 32 | 32 | |||
Concentration, freezing temperature | 50V/V%~ -35°C | 50V/V%~ -35°C | 50V/V%~ -35°C | 50V/V%~ -35°C | |||
Refrigerant (R410A charge) Kg | 11 | 10*2 | 10.5*2 | 10.5*2 | |||
Dimensions | High (mm) | 2296 | 2296 | 2296 | 2296 | ||
Width (mm) | 1006 | 1006 | 1006 | 1006 | |||
Long (mm) | 1436 | 2006 | 2006 | 2006 | |||
Weight (Kg) | 600 | 9000 | 1000 | 1000 | |||
Maximum water resistance (Kpa) | 50 | 50 | 50 | 50 | |||
Piping interface | Air conditioning water pipe | DN40 flange | DN50 flange | DN50 flange | DN50 flange | ||
Domestic hot water pipe | G1-1/4” inner screw | G1-1/4” inner screw | G1-1/4” inner screw | G1-1/4” inner screw | |||
Gas piping (mm) | Rc1/2” | Rc3/4” | Rc3/4” | Rc3/4” | |||
Running noise dB (A) | 60 | 61 | 62 | 62 | |||
Fan | Air supply form | Axial Fan*1 | Axial Fan*2 | Axial Fan*2 | Axial Fan*2 | ||
Rated air volume M3/h | 1500 | 25000 | 27000 | 27000 |
Remark:
1. Refrigeration: The outdoor temperature is 35°C, and the outlet water temperature is 7°C. When the outlet water temperature is lower than 5°C during operation, antifreeze must be used as the refrigerant water.
2. The amount of heat recovery under refrigeration conditions: the outlet water temperature is 45°C. (Please note that this function is required when ordering)
3. Heating (nominal): outdoor temperature 7/6°C, outlet water temperature 45°C; heating (low temperature): outdoor temperature 2/1°C, outlet water temperature 45°C.
4. The type of gas is natural gas, and the pressure is low pressure. (Maximum pressure: 2.5kpa; Standard pressure: 2.0kpa; Minimum pressure 1.0kpa)
5. Actual gas consumption (Nm3/h) = gas consumption (kW) X3.6/35.4 (MJ/Nm3)
6. If the product is updated, the data is subject to change without prior notice.