Product Details
Fluorescence Immunoassay Analyzer (Handheld)
Application
Fluorescence Immunoassay Analyzer is an analyzer that based on
detection of fluorescence emitted during an immunoassay with
antigen-antibody interaction. The analyzer is designed to be used for quantitative
or qualitative detection of human samples with specific in vitro
diagnostic test units including Inflammation Markers, Tumor Markers, Nephrology,
Diabetes, Cardiac Markers, Coagulation, Endocrinology,
Autoimmunity, Infectious Diseases and etc. Fluorescence Immunoassay Analyzer offers the
advantages of high accuracy, strong stability and fast results.
Fluorescence Immunoassay Analyzer should only be used with in vitro diagnostic
tests manufactured by Hangzhou AllTest Biotech Co., Ltd. as per package
insert provided with specific test kits.
For professional and Point of Care in vitro diagnostic use only.
Scope of Application
Fluorescence Immunoassay Analyzer works with certain fluorescent
reagents. It’s for professional in vitro diagnostic and Point of Care Use. It
may be used in central laboratories of medical institutions, outpatient or
emergency departments, clinical departments or medical services (such as
community health centers), or medical center, etc. It can also be used in
researchlaboratories
Technical Specifications
Test Method: | Fluorescence Immunoassay |
Test Format: | Cassette |
Measurement: | Quantitative, Qualitative |
Read Time: | < 20 Seconds |
Display: | 8000 Records |
Memory: | DC 15V,AC 100-240V 50/60Hz |
Power Source: | Rechargeable Li-ion |
Built- in Battery: | battery(3300mAh*3) |
Storage Condition: | -10-40℃,RH:20-90%, 86-106kPa |
Printer: | Built-in thermal printer |
Connectivity: | USB port, RS232 COM port, WIFI |
Compatibility: | LIS |
Dimensions(L*W*H): | 270*127*115mm |
Weight: | <1.2kg |
Directions for Use
The Fluorescence Immunoassay Analyzer can be operated by commands
on touchscreen.
1 System Installation
1) Connect power with analyzer through the DC adapter, press the
power switch to turn on the analyzer.
2) After starting the analyzer, the initializing screen will
display.
Note: If the initializing failed, it is recommended to contact the manufacturer or the local distributor.
3) After initializing, the main interface will display.
This is the main operation interface of the analyzer. Here you can
choose the Test, Test Items, History and Settings
2 Settings
Tap "Settings" to display the secondary menu in the interface. System Settings
1) Tap "Time" to enter the year, month, day, hour, minute, second and tap "Set" to modify the system time. Tap "Time zone" to adjust the UTC time.
2) Tap "Language" to select the corresponding language, and tap "OK" to switch the system language.
3) Tap "Net Set" to enter the interface. and tap "WiFi" to enter the interface below for wifi settings. Tap the "WLAN Switch" and choose the WLAN you need in the "Valid WLAN list". Then enter the password.
4) Tap "Port Set" to enter the interface.
Generally the default serial port is connected to the LIS. If it is used to connect to a scanner or PC, leave LIS port unchecked and
then check the appropriate option.
5) Tap "Backlight" to adjust the brightness of the display. Tap "LIGHTEN" or "DIM" to adjust the screen brightness.
6) Tap "About" to enter the interface for more information related to the
analyzer. The Software Version and Serial Number are displayed on
the
screen.
Maintenance
Basic maintenance is to keep the outside of the Fluorescence
Immunoassay Analyzer clean.
External cleaning and maintenance method: Clean the outer surface of the analyzer with a damp cloth with no
more than 70% alcohol. Do not use strong bleach (≥ 0.5% bleach
solution), because oxidizing substances and solvents may damage the
parts of analyzer and touch screen. Do not clean any internal parts and inner surface.
Company Profile
HANGZHOU ALLTEST BIOTECH CO.,LED has a solid foundation with
top-notch industry professionals, having proven expertise in
innovation management including new introductions, be it a product
or be it industry transforming process developments. We have been
witness to as well as been part of core teams that have been
responsible for transformations, which are critical today’s Rapid
Tests as well as POCT business.
Some of them include industry-leading design control systems that
are responsible for innovative products with high quality as well
as validations protocols that form the core of stringent quality
assessment systems.
HANGZHOU ALLTEST BIOTECH CO.,LTD has been created with the sole
objective of benefitting the stakeholders in healthcare industry
with major stake in POCT business including rapid tests.
HANGZHOU ALLTEST BIOTECH CO.,LTD is committed to bring Innovative
Solutions including convergence of rapid test’ ease with the power
of modern day electronics, thereby helping the creation of new
technological platforms as well as business processes that unlocks
the true potential of amalgamation of technology and commerce with
new milestones in techno-commercial sectors of POCT industry.
In a nutshell, with HANGZHOU ALLTEST BIOTECH CO.,LTD, you can
“Relax” and leave the worries of today and tomorrow with better
solutions for you than solutions available today.