

Add to Cart
TECHNICAL SPECIFICATIONS ND9000 INTELLIGENT VALVE CONTROLLER General Loop powered, no external power supply required. Suitable for rotary and linear valves. Actuator connections in accordance with VDI/VDE 3845 and IEC 60534-6 standards. Flush mounting on selected actuators Action: Double or single acting Travel range: Linear; 10–120 mm / 0.4-4.7 in rotary; 45–95 degrees. Measurement range 110° with freely rotating feedback shaft. Environmental influence Standard temperature range: -40° – +85 °C / -40° – +185 °F Arctic temperature range: -53° – +85 °C / -64° – +185 ° Influence of temperature on valve position: 0.5 % /10 °K Influence of vibration on valve position: < 1 % under 2g 5–150 Hz, 1g 150–300 Hz, 0.5g 300–2000 Hz Enclosure Material: ND9100: Anodized aluminum alloy and polymer composite ND9200: Anodised aluminum alloy and tempered glass ND9400: Stainless steel and polymer composite ND9300: Stainless steel Protection class: IP66, Nema 4x Pneumatic ports: G 1/4 (ND9100) 1/4 NPT (ND9200, ND9300 & ND9400) Cable gland thread: M20x1.5 (ND9000 ) 1/2 NPT (ND9000E2, ND9000U) Weight: 1.8 kg / 4.0 lbs (ND9100) 3.4 kg / 7.5 lbs (ND9200) 5.6 kg / 12.4 lbs (ND9400) 8.6 kg / 19.0 lbs (ND9300) Mechanical and digital position indicator visible through main cover, not applicable to ND9200E2 and ND9300. Special corrosion resistant design or stainless steel housing available as an option for demanding environment. Pneumatics Supply pressure: 1.4–8 bar / 20–115 psi Effect of supply pressure on valve position: < 0.1 % at 10 % difference in inlet pressure Air quality: Acc. to ISO 8573-1 Solid particles: Class 5 (3 – 5 μm filtration is recommended) Humidity: Class 1 (dew point 10 °C/ 18 °F below minimum temperature is recommended) Oil class: 3 ( or < 1 ppm) Capacity with 4 bar / 60 psi supply: 5.5 Nm3/h / 3.3 scfm (spool valve 2) 12 Nm3/h / 7.1 scfm (spool valve 3) 38 Nm3 /h /22,4 scfm (spool valve 6) Consumtion with 4 bar / 60 psi supply in steady state position: < 0.6 Nm3/h /0.35 scfm (spool valve 2 & 3) < 1.0 Nm3/h / 0.6 scfm (spool valve 6) Electronics HART Supply power: Loop powered, 4–20 mA Minimum signal: 3.6 mA Current max : 120 mA Load voltage: up to 9.7 VDC/20 mA (corresponding 485 Ω) Voltage: max. 30 VDC Polarity protection: -30 VDC Over current protection: active over 35 mA Profibus PA and FOUNDATION fieldbus Supply power: voltage 9–32 VDC, reverse polarity protection Max basic current: 17.2 mA Quiescent Current Draw: 16 mA Fault current (FDE): 3.9 mA FOUNDATION fieldbus function block execution times AO 20 ms AI 20 ms PID 20 ms DO 20 ms DI 15 ms IS 15 ms OS 15 ms Performance with moderate constant-load actuators Dead band: ≤ 0.1 % Hysteresis: < 0.5 % Local User Interface (LUI) functions □ Local control of the valve □ Monitoring of valve position, target position, input signal, temperature, supply and actuator pressure difference □ Guided-startup function □ LUI may be locked remotely to prevent unauthorised access □ Calibration: Automatic / Manual linearization □ 1-point calibration □ Control configuration: aggressive, fast, optimum, stable, maximum stability □ HART version configuration: HART 6 or HART 7 □ Configuration of the control valve □ Rotation: valve rotation clockwise or counter-clockwise to close □ Dead Angle □ Low cut-off, cut-off safety range (default 2 %) □ Positioner fail action, open/close □ Signal direction: Direct/reverse acting □ Actuator type, double/single acting □ Valve type, rotary/linear □ Language selection: English, German and French Position transmitter (optional) Output signal: 4–20 mA (galvanic isolation; 600 VDC) Supply voltage: 12–30 VDC Resolution: 16 bit / 0.244 μA Linearity: < 0.05 % FS Temperature effect: < 0.35 % FS External load: max 0–780 Ω max 0–690 Ω for intrinsically safe Ex ia IIC T6 Ui ≤ 28 V Ex d IIC T4/T5/T6 Ui ≤ 30 V METSO 4 TECHNICAL BULLETIN 11/16 7 ND90 21 EN APPROVALS AND ELECTRICAL VALUES, HART Certificate Approval Electrical values ATEX ND_X VTT 09 ATEX 033X VTT 09 ATEX 034X EN 60079-0: 2009/2012 EN 60079-11: 2012 EN 60079-26: 2007 EN 60079-31: 2008 EN 60079-0: 2009/2012 EN 60079-11: 2012 EN 60079-15: 2010 EN 60079-31: 2008 II 1G Ex ia IIC T6...T4 Ga II 1D Ex ta IIIC T90 °C Da II 2 G Ex ib IIC T6...T4 Gb II 2 D Ex tb IIIC T90 °C Db Input: Ui ≤ 28 V, Ii ≤ 120 mA, Pi ≤ 1 W, Ci ≤ 22 nF, Li ≤ 53 μH. Output: Ui ≤ 28 V, Ii ≤ 120 mA, Pi ≤ 1 W, Ci ≤ 22 nF, Li ≤ 53 μH, external load resistance 0–690 Ω II 3 G Ex nA IIC T6...T4 Gc II 3 D Ex tc IIIC T90 °C Dc Input: Ui ≤ 30 V, Ii ≤ 152 mA Output: Ui ≤ 30 V, Ii ≤ 152 mA II 3 G Ex ic IIC T6...T4 Gc II 3 D Ex tc IIIC T90 °C Dc Input: Ui ≤ 30 V, Ii ≤ 152 mA, Pmax = device limits itself, Ci ≤ 22 nF, Li ≤ 53 μH. Output: Ui ≤ 30 V, Ii ≤ 152 mA, Pmax = device limits itself, Ci ≤ 22 nF, Li ≤ 53 μH, external load resistance 0–780 Ω ND_E1 SIRA 11 ATEX 1006X EN 60079-0:2009 EN 60079-1:2007 EN 60079-31:2009 II 2 G Ex d IIC T6...T4 Gb II 2 D Ex tb IIIC T80 °C...T105 °C Db Input: Ui ≤ 30 V Output: Ui ≤ 30 V, Pmax = device limits itself, external load resistance 0–780 Ω IECEx ND_X IECEx VTT 10.0004X IECEx VTT 10.0005X IEC 60079-0: 2007/2011 IEC 60079-11: 2011 IEC 60079-26: 2006 IEC 60079-31: 2008 IEC 60079-0: 2007/2011 IEC 60079-11: 2011 IEC 60079-15: 2010, IEC 60079-31: 2008 Ex ia IIC T6...T4 Ga Ex ta IIIC T90 °C Da Ex ib IIC T6...T4 Gb Ex tb IIIC T90 °C Db Input: Ui ≤ 28 V, Ii ≤ 120 mA, Pi ≤ 1 W, Ci ≤ 22 nF, Li ≤ 53 μH Output: Ui ≤ 28 V, Ii ≤ 120 mA, Pi ≤ 1 W, Ci ≤ 22 nF, Li ≤ 53 μH, external load resistance 0–690 Ω Ex nA IIC T6...T4 Gc Ex tc IIIC T90 °C Dc Input: Ui ≤ 30 V, Ii ≤ 152 mA Output: Ui ≤ 30 V, Ii ≤ 152 mA Ex ic IIC T6...T4 Gc Ex tc IIIC T90 °C Dc Input: Ui ≤ 30 V, Ii ≤ 152 mA, Pmax = device limits itself, Ci ≤ 22 nF, Li ≤ 53 μH Output: Ui ≤ 30 V, Ii ≤ 152 mA, Pmax = device limits itself, Ci ≤ 22 nF, Li ≤ 53 μH, external load resistance 0–780 Ω ND_E1 IECEx SIR 11.0001X IEC 60079-0:2011 IEC 60079-1:2007 IEC 60079-31:2008 Ex d IIC T6...T4 Gb Ex tb IIIC T80 °C...T105 °C Db Input: Ui ≤ 30 V Output: Ui ≤ 30 V, Pmax = device limits itself, external load resistance 0–780 Ω INMETRO ND_Z NCC 12.0793 X NCC 12.0794 X ABNT NBR IEC 60079-0:2013 ABNT NBR IEC 60079-11:2009 ABNT NBR IEC 60079-26:2008 (2009) ABNT NBR IEC 60079-27:2010 ABNT NBR IEC 60079-0:2013 ABNT NBR IEC 60079-11:2009 IEC 60079-15:2012 ABNT NBR IEC 60079-27:2010 ABNT NBR IEC 60529:2005 Ex ia IIC T4/T5/T6 Ga Ex ia IIC T4/T5/T6 Gb Input: Ui ≤ 28 V, Ii ≤ 120 mA, Pi ≤ 1 W, Ci ≤ 22 nF, Li ≤ 53 μH Output: Ui ≤ 28 V, Ii ≤ 120 mA, Pi ≤ 1 W, Ci ≤ 22 nF, Li ≤ 53 μH, external load resistance 0–690 Ω. Ex nA IIC T4/T5/T6 Gc Input: Ui ≤ 30 V, Ii ≤ 152 mA Output:Ui ≤ 30 V, Ii ≤ 152 mA Ex ic IIC T4/T5/T6 Gc Input: Ui ≤ 30 V, Ii ≤ 152 mA, Pmax = device limits itself, Ci
Safety | IEC 61508 |
Descpition | ND9102HN |
Wayyanty | 1 year |