

Add to Cart
Experion Series C input/output chassis-less mounted modules and
field level network gateways provide the physical connection
between an automation system and the process when used with the
C300 Controller. Input/Output Modules and field terminations are
combined in the same area. The Input/Output Modules are plugged
into Input /Output Termination Assemblies to eliminate the need for
a separate chassis to hold the electronics assemblies. C300
Controller The C300 Controller is constructed using the Series C
form factor that employs an Input Output Termination Assembly
(IOTA) and an electronics module which mounts and connects to the
IOTA. One C300 Controller contains all of the control functionality
and the communications functions with plug-in modules. The C300
Controller may operate in both non-redundant and redundant
configurations. Redundant operation requires a second identical
controller and connecting cables, which is the typical
configuration. The C300 Controller is connected to the associated
I/O hardware by a pair of I/O Link Interface cables The table below
identifies the C300 Controller components and its associated
components. TheC300 Controller supports non-redundant and fully
redundant operation. Redundancy is built in to the controller, so
that just adding another controller and a redundancy cable; a
redundant controller pair is achieved. Note that the ‘CC’
designation on the model number indicates the printed wiring boards
are conformally coated for additional protection from the
environment, (CU = uncoated).
This document provides technical information to configure the
Series 8 I/O. The following Series 8 I/O items are included in this
document. • TC/RTD • Analog Input – Single Ended • Analog Input
with HART – Single Ended • Analog Input with HART – Differential •
Analog Output • Analog Output with HART • Digital Input Sequence of
Events (SOE) • Digital Input, 24 VDC • Digital Input Pulse
Accumulation • Digital Output, 24 VDC • DO Relay Extension Board
Definitions • Input Output Termination Assembly (IOTA): An assembly
that holds the IOM and the connections for field wiring; • Input
Output Module (IOM): A device that contains most of the electronics
required to perform a specific I/O function. The IOM plugs onto the
IOTA. Features All Series 8 components feature an innovative design
that supports enhanced heat management. This unique look provides
significant reduction in overall size for the equivalent function.
The unique features of Series 8 I/O include: • I/O Module and field
terminations are combined in the same area. The I/O Module is
plugged into the IOTA to eliminate the need for a separate chassis
to hold the electronics assemblies • Two level “detachable”
terminals for landing the field wiring in the enclosure, providing
easier plant installation and maintenance. • Field power is
supplied through the IOTA, with no need for extra power supplies to
power the field devices and the associated craft wired marshalling
• Redundancy is accomplished directly on the IOTA without any
external cabling or redundancy control devices, by simply adding a
second IOM to an IOTA • For both IOM and IOTA, coated (module
numbers starting with 8C) and uncoated (module numbers starting
with 8U) options are provided. Conformal coating material is
applied to electronic circuitry to act as protection against
moisture, dust, chemicals, and temperature extremes. Coated IOM and
IOTA are recommended when electronics must withstand harsh
environments and added protection is necessary.
item | value |
Place of Origin | USA |
Brand Name | Honeywell |
Model Number | |
Product type | C300 |
Power supply | 24Vdc |
Product name | Analog Input/output I/O Module |
Shipping weight | 2 kg |
Size | 12.1cm x 14.5cm |
Shipping By | DHLUPSFedexTNTEMSOthers |
Quality | High |
Condition | 100% Original |
Package | Standard Packing |
MOQ | 1 |
Experion Series C System Components’ List
CU-CBDS01 Series C, Single Access Cabinet
CU-CBDD01 Series C, Dual Access Cabinet
CC-MCAR01 IOTA Carrier Channel Assembly
Ca-PCNT01 C300Controi Processor
Ca-TCNT01 C300Controi Processor IOTA
Ca-PAIH01 Hi-level AI HART
CA-TAIX01 Hi-level AI HART IOTA
Ca-TAIX11 Hi-level AI HART IOTA - Redundant
Ca-PAOH01 AO 16pt HART
Ca-TAOX01 AOIOTA
Ca-TAOX11 AO IOTA - Redundant
Ca-PDIL01 Dl24V
Ca-TDIL01 Dl24VIOTA
Ca-TDIL11 DI 24V IOTA - Redundant
Ca-PDOB01 DO 24V Bussed Out
Ca-TDOB01 DO 24V Buss IOTA
Ca-TDOB11 DO 24V Buss IOTA - Redundant
Ca-TDOR01 DO Relay IOTA
Ca-TDOR11 DO Relay IOTA - Redundant
Ca-SDOR01 DO Relay Extension Board
Ca-PFB401 Fieldbus - 4 Nets
Ca-TFB402 Fieldbus IOTA - 4 Nets
Ca-TFB412 Fieldbus IOTA - Redundant - 4 Nets
Ca-PAIM01 PMIOLLMux
Ca-TAIM01 PMIO LLMux IOTA
Ca-TAMT04 LLMuxTCFTA
Ca-TAMR01 LLMux RTD FTA
Ca-PCF901 Control Firewall (8 port + 1 uplink)
Ca-TCF901 Control Firewall IOTA
Ca-FSMx01 FTE Single Model Fiber Module
Ca-FMMx01 FTE Multi-Model Fiber Module
Ca-PDIH01 Digital Input High Voltage
Ca-TDI110 DI 110 Vac IOTA
Ca-TDI120 DIII0 Vac IOTA - Redundant
Ca-TD1220 DI 220 Vac IOTA
Ca-TDI230 DI 220 Vac IOTA - Redundant
Ma-TAMT04 Low Level Multiplexer Thermocouple Field Termination
Assembly
Ma-TAMR04 Low Level Multiplexer RTD Field Termination Assembly