EEV MG5436 25kW X-band Marine Radar Magnetron


Compact, rugged, lightweight, magnetron MG5436 X-Band fixed frequency pulses intended for use in marine radar. The recommended value for the MG5436 voltage is 6.3V, but a magnetron operating correctly and within the prescribed limits.
Specifications:
  • Operating Frequency: 9410 MHz + 30
  • Typical peak power: 25 kW
  • Heater voltage: 6,3 V
  • Heater current at 6.3 V: 0.5 A
  • The minimum clearance of 25 mm must be maintained between the magnetron and any magnetic material.

Brand NameE2V
PartMAGNETRON
New OriginalYES
POWER25KW
FREQUENCY9410 + 30 MHz
Weight2Kg

HEALTH AND SAFETY HAZARDS

E2V Technologies magnetrons are safe to handle and operate, provided that the relevant precautions stated herein are observed. E2V Technologies does not accept responsibility for damage or injury resulting from the use of electronic devices it produces. Equipment manufacturers and users must ensure that adequate precautions are taken. Appropriate warning labels and notices must be provided on equipments incorporating E2V Technologies devices and in operating manuals.

High Voltage

Equipment must be designed so that personnel cannot come into contact with high voltage circuits. All high voltage circuits and terminals must be enclosed and fail-safe interlock switches must be fitted to disconnect the primary power supply and discharge all high voltage capacitors and other stored charges before allowing access. Interlock switches must not be bypassed to allow operation with access doors open.

RF Radiation

Personnel must not be exposed to excessive RF radiation. All RF connectors must be correctly fitted before operation so that no leakage of RF energy can occur and the RF output must be coupled efficiently to the load. It is particularly dangerous to look into open waveguide or coaxial feeders while the device is energised. Screening of the cathode sidearm of high power magnetrons may be necessary.

X-Ray Radiation

High voltage magnetrons emit a significant intensity of X-rays not only from the cathode sidearm but also from the output waveguide. These rays can constitute a health hazard unless adequate shielding for X-ray radiation is provided. This is a characteristic of all magnetrons and the X-rays emitted correspond to a voltage much higher than that of the anode