Dwyer Low Differential Pressure Switch 10 Psig 15A SPDT 60Hz 15A

Brand Name:DWYER
Certification:CE
Model Number:1823-10-20-40-5
Minimum Order Quantity:10
Delivery Time:5-8 days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Wenzhou Zhejiang China
Address: 58 Longhe Road, Liushi Town,Wenzhou, Zhejiang, China 325604
Supplier`s last login times: within 14 hours
Product Details Company Profile
Product Details

Dwyer 1823-10/-20/-40/-5 LOW DIFFERENTIAL PRESSURE SWITCH 10 psig 15 A 1800 series

Set Points from 0.07" to 85" w.c. Repetitive Accuracy within 2%

Essential for industrial environments, the Series 1800 Low Differential Pressure Switch for general industrial service combines small size and low price with 2% repeatability for all but the most demanding applications. Set point adjustment inside the mounting stud permits mounting the switch on one side of a wall or panel with adjustment easily accessible on the opposite side. UL and CSA listed, and FM approved.

FEATURES

  • Compact size and repeatability provide a high-value switch for many industrial applications
  • Designed for panel and wall mounting to easily meet mounting requirements in most industrial settings
  • Pressure ranges from 0.07 in w.c. to 85 in w.c. make this switch suitable for a wide range of applications

SPECIFICATIONS


ServiceAir and non-combustible, compatible gases
Wetted MaterialsConsult factory
Temperature Limits-30 to 180°F (-34 to 82.2°C); 1823-00: -20 to 180°F (-28.9 to 82.2°C).
Pressure Limits10 psig (68.95 kPa) continuous, 25 psig (172.4 kPa) surge.
Switch TypeSingle-pole double-throw (SPDT).
Repeatability±2%
Electrical Rating15A @120-480 VAC, 60 Hz.
Process Connection1/8˝ female NPT



DESCRIPTION

Essential for industrial environments, the Series 1800 Low Differential Pressure Switch for General Industrial Service combines small size and low price with 2% repeatability for all but the most demanding applications. Set point adjustment inside the mounting stud permits mounting the switch on one side of a wall or panel with adjustment easily accessible on the opposite side. UL and CSA listed, and FM approved.



APPLICATIONS

Process applications

• Mechanical equipment control



APPROVALS


ADJUSTMENT

1. If the switch has been factory preset, check the set-point before placing in service to assure it has not shifted in transit.

2. If switching has not been preset or it is desired to change the point, observe the following procedure:

a. To adjust the set point turn the slotted Adjustment Screw clockwise to increase the set point and counterclockwise to decrease the set point.

b. The following is a recommended procedure for calibrating or checking calibration: Use a “T” assembly with three rubber tubing leads, all as short as possible and the entire assembly offering minimum flow restriction. Run one lead to the pressure switch, another to a manometer of known accuracy and appropriate range, and apply pressure through the third tube. Make final approach to the set point slowly. Note the manometer and pressure switch will have different response characteristics due to different internal volumes, lengths of tubing, oil drainage, etc. Be certain switch is checked in position it will assume in use, i.e. vertical, horizontal, etc.

ACCESSORIESMODEL CHART

INSTALLATION

1. Select a location free form excessive vibration and where oil or water will not drip upon the switch. See special housings for unusual conditions.

2. While not required, positioning the pressure connections down is recommended. Mount the switch with the diaphragm in a vertical plane. Switch with the diaphragm in a vertical plane. Switch must be recalibrated for each change in operating position.

3. Connect switch to source of pressure differential. Metal tubing with 1/4˝ O.D. is recommended but any tubing system which will not restrict the air flow is satisfactory. Note that the low pressure connection may be made to the 1/2˝ spud at the back of the switch if desired. If so connected, drill 1/16˝ diameter holes in the Spring Retainer flange and the head of Adjustment Screw to provide opening to the switch interior and plug the other low pressure connection.

4. Electrical connections to the standard single pole, double throw snap switch are provided by means of screw terminals marked “common”, “norm open”, and “norm closed”. The normally open contacts close and the normally closed contact open when pressure increases beyond the set point.

5. Switch loads should not exceed the maximum specified current rating of 15 amps resistive. Switch capabilities decrease with high load inductance or rapid cycle rates. Whenever and application involves one or more of these factors, the user may find it desirable to limit the switched current to 10 amps or less in the interest of prolonged switch life.

China Dwyer Low Differential Pressure Switch 10 Psig 15A SPDT 60Hz 15A supplier

Dwyer Low Differential Pressure Switch 10 Psig 15A SPDT 60Hz 15A

Inquiry Cart 0