Miniature PLC Logic Controller Thermocouple Input Integrated PLC 220v ac

Brand Name:xinje
Certification:CCC
Model Number:XD3-22T4TC-E
Minimum Order Quantity:1
Delivery Time:14 Work days
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Wenzhou Zhejiang China
Address: 58 Longhe Road, Liushi Town,Wenzhou, Zhejiang, China 325604
Supplier`s last login times: within 14 hours
Product Details Company Profile
Product Details

XD3-22T4TC-E PLC

XD3 series special model integrates logic control and thermocouple input. Digital value input: 8 points (NPN optocoupler isolation), digital value output: 14 points (transistor type); thermocouple signal input: 4 points


Product features

XD3 series special model integrates logic control and thermocouple input.

Digital value input: 8 points (NPN optocoupler isolation), digital value output: 14 points (transistor type)

Thermocouple signal input: 4 points

Power specification: AC220V

Support 2 channels of AB phase input

Support 2 channels of high-speed counting (10kHz)

Support MODBUS and X-NET communication

High cost performance, greatly saving space


Model list

ModelFunction
XD3-22T4TC-E

8-channel NPN type digital value input, 14-channel

transistor output, 4-channel thermocouple signal input


Function table

SeriesUSB portRS232 portRS485Free communicationExtension moduleExtension BDLeft extension EDHigh speed counting channelPulse outputExternal interrupt
Increase modeAB phase
XD3-22T4TC×2×××222

6

General Specifications

ItemSpecification
IsolationAbove DC 500V 2MΩ
Anti-noiseNoise voltage 1000Vp-p 1us pulse 1 minute
AirNo corrosive, flammable gas
Ambient temperature0℃~60℃
Ambient humidity

5%~95% (no condensation)


USB port-
COM1RS232(default X-NET protocol), connect upper PC for programming and debug
COM2RS232(default Modbus), connect upper PC or HMI for programming and debug
COM3RS485, connect to intelligent instrument and frequency inverter
InstallationUse M3 screws or DIN rail to fix
Ground (FG)The third type grounding (do not grounding with strong power system)

Functional Specifications

ItemSpecification
Program execution modeLoop scan mode
Programming modeCommand and ladder chart
Processing speed0.02~0.05us
Power-off retentiveFlashROM and 3V lithium battery
User program capacity ※1256kB

I/O

points

※2

Total points22 points
Input points8 points X0~X7
Output points14 points Y0~Y15
Internal coils (X)※31280 points: X0~X77, X10000~X11777, X20000~X20177, X30000~X30077
Internal coils (Y) ※41280 points: Y0~Y77, Y10000~Y11777, Y20000~Y20177, Y30000~Y30077

Internal coils

(M, HM)

11008 pointsM0~M7999【HM0~HM959】※5
Flow (S)1152 pointsS0~S1023【HS0~HS127】
Timer (T)Points712 pointsT0~T575【HT0~HT95】
Precise timer ET0~ET39
Spec

100ms timer: 0.1~3276.7s

10ms timer: 0.01~327.67s

1ms timer: 0.001~32.767s

Counter (C)Points712 pointsC0~C575【HC0~HC95】
High speed counter HSC0~HSC39
Spec

16-bit counter: K0~32,767

32-bit counter: -2147483648~+2147483647

Data register (D)11548 wordsD0~D7999【HD0~HD999】※5
Special use ※6 SD0~SD2047 【HSD0~HSD499】※5

FlashROM register

(FD)

8192 wordsFD0~FD6143
Special use ※6 SFD0~SFD1999
Special encrypted register FS0~FS47
Special coil for WAIT instruction32 pointsSEM0~SEM31
High speed processing abilityHigh speed counter, pulse output, external interruption
Password protection6-bit ASCII
Self-diagnose function

Power on self-check, monitor timer, grammar check


Notes:
※ 1: User program capacity refers to the maximum program capacity during secret download.
※ 2: I / O points refer to the number of terminals that users can access and output signals from the outside.
※ 3: X refers to the internal input relay, and X exceeding I points can be used as intermediate relay.
※ 4: y refers to the internal output relay. Y exceeding O points can be used as an intermediate relay.
※ 5: [ ] flag, which is the default power-off holding area and cannot be changed.
※ 6: Special use refers to the special purpose register occupied by the system, which can not be used for other purposes.
※ 7: The numbers of input coils and output relays / transistors are octal numbers, and the numbers of other memories are decimal numbers.
※ 8: I / O without real connection with peripheral equipment can be used as fast internal relay.


Function configuration table:

ItemContents
Analog inputK, S, E, N, B, T, J, R types of thermocouple
Measuring temperature rangeType K0℃~1300℃
Type S0℃~1700℃
Type E0℃~600℃
Type N0℃~1200℃
Type B0℃~1800℃ (display 0 below 250℃)
Type T0℃~400℃
Type J0℃~800℃
Type R0℃~1700℃
Digital output range

0~max measuring temperature value ×10 (take type K as an example, the digital output range is 0~13000)

Signed 16 bits, binary

Control precision±0.5℃
Resolution0.1℃
Comprehensive accuracy1%(Relative maximum)
Conversion speed80ms/1 channel

Note:

(1) When there is no signal input, the channel data is - 1.

(2) Connect thermocouples according to actual needs.

(3) The enclosure of the equipment installed by the thermocouple must be grounded.



China Miniature PLC Logic Controller Thermocouple Input Integrated PLC 220v ac supplier

Miniature PLC Logic Controller Thermocouple Input Integrated PLC 220v ac

Inquiry Cart 0