4.4oz Adjustable Differential Pressure Switch 1/2" NPT Connection

Brand Name:Dwyer
Certification:ADPS-03-1-N
Model Number:ADPS-03-1-N
Minimum Order Quantity:10
Delivery Time:14 Work days
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Wenzhou Zhejiang China
Address: 58 Longhe Road, Liushi Town,Wenzhou, Zhejiang, China 325604
Supplier`s last login times: within 14 hours
Product Details Company Profile
Product Details

SERIES ADPS/EDPS DIFFERENTIAL PRESSURE SWITCH

With Dual Scale Field Adjustable Set Point Knob

The Series ADPS/EDPS Adjustable Differential Pressure Switch is designed for pressure, vacuum, and differential pressures. The dual scaled adjustment knob in inches water column and pascals allows changes to the switching pressure to be made without a pressure gage. The ADPS/EDPS is available with settings from 0.08 in w.c. (20 Pa) up to 20 in w.c. (5000 Pa). The silicone diaphragm and PA 6.6 body make the series ADPS ideal for use with air and other noncombustible gases. Series EDPS models meet UL508 and are constructed of plenum rated plastics. The compact size, adjustment knob and low cost make the ADPS/EDPS the perfect choice for HVAC applications.

Please see Series AT-ADPS for ATEX approved.

PRODUCT APPLICATIONS

  • Monitoring air filters and ventilators.
  • Monitoring industrial cooling-air circuits.
  • Overheating protection for fan heaters.
  • Monitoring flows in ventilation ducts.
  • Controlling air and fire-protection dampers.
  • Frost protection for heat exchanges.

ModelDescription
ADPS-03-1-NAdjustable differential pressure switch, set point range 0.20 to 2.00" w.c., 1/2" NPT connection.
ADPS-03-2-NAdjustable differential pressure switch, set point range 0.20 to 2.00" w.c., M20 connection.
ADPS-03-2-N-CAdjustable differential pressure switch, set point range 0.20 to 2.00" w.c., M20 connection, with two static tips and 7 ft (2.1 m) of PVC tubing.
ADPS-04-1-NAdjustable differential pressure switch, set point range 0.12 to 1.60" w.c., 1/2" NPT connection.
ADPS-04-2-NAdjustable differential pressure switch, set point range 0.12 to 1.60" w.c., M20 connection.
ADPS-04-2-N-CAdjustable differential pressure switch, set point range 0.12 to 1.60" w.c., M20 connection, with two static tips and 7 ft (2.1 m) of PVC tubing.
ADPS-05-1-NAdjustable differential pressure switch, set point range 0.80 to 4.00" w.c., 1/2" NPT connection.
ADPS-05-2-NAdjustable differential pressure switch, set point range 0.80 to 4.00" w.c., M20 connection.
ADPS-05-2-N-CAdjustable differential pressure switch, set point range 0.80 to 4.00" w.c., M20 connection, with two static tips and 7 ft (2.1 m) of PVC tubing.
ADPS-06-1-NAdjustable differential pressure switch, set point range 2.00 to 10.00" w.c., 1/2" NPT connection.
ADPS-06-2-NAdjustable differential pressure switch, set point range 2.00 to 10.00" w.c., M20 connection.
ADPS-06-2-N-CAdjustable differential pressure switch, set point range 2.00 to 10.00" w.c., M20 connection, with two static tips and 7 ft (2.1 m) of PVC tubing.
ADPS-07-1-NAdjustable differential pressure switch, set point range 4.00 to 20.00" w.c., 1/2" NPT connection.
ADPS-07-2-NAdjustable differential pressure switch, set point range 4.00 to 20.00" w.c., M20 connection.
ADPS-07-2-N-CAdjustable differential pressure switch, set point range 4.00 to 20.00" w.c., M20 connection, with two static tips and 7 ft (2.1 m) of PVC tubing.
ADPS-08-1-NAdjustable differential pressure switch, set point range 0.08 to 1.20" w.c., 1/2" NPT connection.
ADPS-08-2-NAdjustable differential pressure switch, set point range 0.08 to 1.20" w.c., M20 connection.
ADPS-08-2-N-CAdjustable differential pressure switch, set point range 0.08 to 1.20" w.c., M20 connection, with two static tips and 7

Service: Air and non-combustible, compatible gases.
Wetted Materials:
ADPS: Diaphragm material: Silicone; Housing material: POM; Switch body: PA 6.6; Cover: Polystyrene;
EDPS: Diaphragm material: Silicone; Housing material: Switch body: PA 6.6; Cover: Polystyrene; Materials UL 94 V-0 rated.
Temperature Limits: Process and ambient temperature from -4 to 185°F (-20 to 85°C).
Storage: -40 to 185°F (-40 to 85°C).
Pressure Limits: Max. Operating Pressure: 40" w.c. (10 kPa) for all pressure ranges.
Switch Type: Single-pole double-throw (SPDT).
Electrical Rating: Max. 1.5 A res./0.4 A ind./250 VAC, 50/60 Hz; Max. switching rate: 6 cycles/min.
Electrical Connections: Push-on screw terminals. M20x1.5 with cable strain relief or optional 1/2" NPT connection.
Process Connections: 5/16" (7.94 mm) outside diameter tubing, 1/4" (6.0 mm) inside diameter tubing.
Enclosure Rating: NEMA 3 (IP54).
Mounting Orientation: Vertically, with pressure connections pointing downwards.
Mechanical Working Life: Over 106 switching operations.
Weight: 4.4 oz (125 g).
Agency Approvals: CE, ETL approved to UL508 and CSA C22.2#14 (EDPS only).

FEATURES

Adjustment knob changes switching pressure easily with a pressure gage reducing components for application Low cost device makes it an excellent solution in BAS and HVAC applications requiring duct control and monitoring Relay contact allows simple integration with DDC or building systems