MC CCC Y100 100mm M20*1.5 radial copper joint iron shell pressure gauge
Pressure gauge
Instrument for measuring the condition of a fluid (liquid or gas) that is specified by the force that the fluid would exert, when at rest, on a unit area, such as pounds per square inch or newtons per square centimetre.
The reading on a gauge, which is the difference between two pressures, is known as the gauge pressure. If the lower of the pressures is the pressure of the atmosphere, the total, or absolute, pressure is the sum of the gauge and atmospheric pressures.
The simplest device for measuring static pressures up to about 90 pounds per square inch (62 newtons per square cm) is a U-tube manometer (shown in the figure), in which one column of a liquid in the tube is open to a region of high pressure and the other column to a region of low pressure. The differential pressure is indicated by the difference in level between the two columns of liquid, and it is calculated as the difference in level multiplied by the density of the liquid. The manometer liquids most commonly used are mercury, oil, alcohol, and water.
Sepcification
Size: | 100mm |
Operating Temperature | -40 - 70 |
Window: | Safety Glass |
Model Number: | Y100 |
Connection thread: | M20*1.5 |
Pressure range: | 0 ~ 60mPa |
Connection thread: | M20*1.5 |
Accuracy: | 1.6% |
Manometer pressure gauges measure pressure on a fluid by balancing one column of fluid against a second column of fluid. This type of pressure gauge is the simplest type and consists of a transparent tube in the form of a “U” that is partially filled with a manometric fluid like mercury.
Absolute pressure gauges are used to measure pressure independent of the natural fluctuations in atmospheric pressure. A reference vacuum is attached to the side of the measuring element, which is not subject to pressure; it has zero pressure with no variation.
Capsule pressure gauge: The sensitive element of the bellows is composed of two diaphragms connected together with circular waves. The pressure of the measuring medium acts on the inside of the capsule cavity, and the resulting deformation can be used to indirectly measure the pressure of the medium. The size of the pressure value is displayed by the pointer. The bellows pressure gauge is generally used to measure the pressure of the gas, and can measure the micro pressure, and the overpressure protection is also possible to a certain extent. When several capsule sensitive components are stacked together, they will produce a large transmission force to measure extremely small pressure.
Main structure
Overflow hole: In the event of an emergency that the Bourdon tube
bursts, the internal pressure will be released to the outside
through the overflow hole to prevent the glass panel from bursting.
Note: In order to maintain the normal performance of the overflow
hole, a space of at least 10mm must be left behind the table, and
the overflow hole cannot be modified or plugged.
Pointer: In addition to standard pointers, other pointers are also
optional.
Glass panel: In addition to standard glass, other special material
glass, such as tempered glass, and non-reflective glass are also
optional.
Performance classification: ordinary type (standard), ordinary type
for steam (M), heat resistant type (H), vibration resistant type
(V), vibration resistant type for steam (MV) heat resistant and
vibration resistant type (HV).
Treatment method: oil-free/water-free treatment to remove the water
or oil remaining in the wetted part during manufacturing.
Exterior designation: The shell color must be specified in addition
to the standard color.
Throttle valve (optional): In order to reduce the pulsating
pressure, the throttle valve is installed at the pressure inlet.
Use attention
1. The meter must be vertical: a 17mm wrench should be used for
tightening during installation, and the case should not be forcibly
twisted; collisions should be avoided during transportation;
2. The temperature of the surrounding environment should be
-25~55℃;
3. The vibration frequency of the working environment is less than
25HZ, and the amplitude is not more than 1mm;
4. Due to the high ambient temperature during use, the indicating
value of the instrument does not return to zero or the indicating
value is out of tolerance, you can cut the sealing rubber plug on
the upper part of the case to make the inner cavity of the
instrument communicate with the atmosphere;
5. The use range of the instrument should be between 1/3 and 2/3 of
the upper limit;
6. Isolation devices should be added when measuring corrosive
media, media that may crystallize, and media with high viscosity;
7. The meter should be checked frequently (at least once every
three months), and if any malfunction is found, it should be
repaired in time;
Selection principle
The selection of the pressure gauge should be based on the
production requirements of the use process, and specific analysis
should be made for the specific situation. On the premise of
meeting the technological requirements, comprehensive consideration
should be given to the principle of economy. Generally, the
following aspects should be considered:
1. Selection of type
The selection of instrument type must meet the requirements of
process production. For example, whether remote transmission,
automatic recording or alarm is required; whether the nature of the
measured medium (such as the temperature of the measured medium,
viscosity, corrosiveness, degree of contamination, flammable and
explosive, etc.) puts forward special requirements for the
instrument, on-site Environmental conditions (such as humidity,
temperature, magnetic field strength, vibration, etc.) require the
type of instrument, etc. Therefore, the correct selection of the
instrument type according to the process requirements is an
important prerequisite for ensuring the normal operation of the
instrument and safe production.
For example, the spring tube of the ordinary pressure gauge is
mostly made of copper alloy (alloy steel is used for high
pressure), while the material of the spring tube of the pressure
gauge for ammonia is all carbon steel (or stainless steel), and
copper alloy is not allowed. Because ammonia reacts with copper and
will explode, ordinary pressure gauges cannot be used for ammonia
pressure measurement.
The oxygen pressure gauge and the ordinary pressure gauge can be
exactly the same in terms of structure and material, but the oxygen
pressure gauge must be oil-free. Because oil enters the oxygen
system and can easily cause an explosion. When calibrating the
oxygen pressure gauge used, oil cannot be used as the working
medium like ordinary pressure gauges, and the oxygen pressure gauge
must be stored strictly to avoid contact with oil. If it is
necessary to use the existing oily pressure gauge to measure the
oxygen pressure, it must be repeatedly cleaned with carbon
tetrachloride before use, and carefully checked until there is no
oil.
2. Determination of the measurement range
In order to ensure that the elastic element can work reliably
within the safe range of elastic deformation, when selecting the
pressure gauge range, there must be enough room according to the
size of the measured pressure and the speed of the pressure change.
Therefore, the upper limit of the pressure gauge It should be
higher than the maximum pressure value possible in process
production. According to "Technical Regulations for Chemical
Automatic Control Design", when measuring stable pressure, the
maximum working pressure should not exceed 2/3 of the upper limit
of measurement; when measuring pulsating pressure, the maximum
working pressure should not exceed 1/2 of the upper limit of
measurement; When measuring high pressure, the maximum working
pressure should not exceed 3/5 of the upper limit of the
measurement. Generally, the minimum value of the measured pressure
should not be lower than 1/3 of the upper limit of the instrument
measurement. So as to ensure the linear relationship between the
output of the meter and the input
After calculating the upper and lower limits of the meter based on
the maximum and minimum values of the measured parameters, this
value cannot be directly used as the measuring range of the meter.
When we select the upper limit of the scale of the instrument, it
should be selected from the standard series prescribed by the
country. The standard series of pressure gauge measurement ranges
in China are: -0.1-0.06,0.15; 0-1,1.6,2.5,4,6,10X10" MPa (where n
is a natural integer. It can be positive or negative).
3. Selection of accuracy level
According to the maximum absolute error allowed by the process
production and the maximum range of the selected instrument, the
maximum quoted error allowed by the instrument is calculated, and
the accuracy of the instrument is determined in the accuracy class
specified by the country. Generally speaking, the more precise the
instrument selected, the more accurate and reliable the measurement
result will be. However, it cannot be considered that the higher
the accuracy of the selected instrument
Usage
Sepcification
Size: | 100mm |
|
|
|
|
|
|
|
|
|
|
|
|
|
|