Add to Cart
Pruduct
The valve is widely used in water supply and drainage, building
fire fighting system and other pipelines, especially fire fighting
pipelines. The valve can be used in non corrosive medium pipeline
or equipment, for closure, connecting and regulating flow.
.Design and manufacture: GB/T 12238 universal valve flange and
clamp connection elastic seal butterfly valve
· Structure length: GB/T 12221 metal valve structure length or
manufacturer's standard
· Connecting end: JB/T 17241.6 integral cast iron flange
· Inspection and test: GB/T 13927 industrial valve pressure test
DN | L | D | D1 | b-f | z-Фd | |||||
10 | 16 | 10 | 16 | 10 | 16 | |||||
50 | 108 | 160 | 125 | 19-3 | 4-Ф18 | |||||
65 | 112 | 180 | 145 | 19-3 | 4-Ф18 | |||||
80 | 114 | 195 | 160 | 19-3 | 8-Ф18 | |||||
100 | 127 | 215 | 180 | 19-3 | 8-Ф18 | |||||
125 | 140 | 245 | 210 | 19-3 | 8-Ф18 | |||||
150 | 140 | 280 | 240 | 19-3 | 8-Ф23 | |||||
200 | 152 | 335 | 295 | 20-3 | 8-Ф23 | 12-Ф23 | ||||
250 | 165 | 390 | 405 | 350 | 355 | 22-3 | 12-Ф23 | 12-Ф28 | ||
300 | 178 | 440 | 460 | 400 | 410 | 24.5-4 | 12-Ф23 | 12-Ф28 | ||
350 | 190 | 505 | 520 | 460 | 470 | 30-4 | 16-Ф23 | 16-Ф28 | ||
400 | 216 | 565 | 580 | 515 | 525 | 32-4 | 16-Ф28 | 16-Ф31 | ||
450 | 222 | 615 | 640 | 565 | 585 | 32-4 | 20-Ф28 | 20-Ф31 | ||
500 | 229 | 670 | 715 | 620 | 650 | 34-4 | 20-Ф28 | 20-Ф34 | ||
600 | 267 | 780 | 840 | 725 | 770 | 36-5 | 20-Ф31 | 20-Ф37 | ||
700 | 292 | 895 | 840 | 40-5 | 24-Ф31 | |||||
800 | 318 | 1015 | 950 | 44-5 | 24-Ф34 |
Main part | Part material |
Body | Grey iron+NRB,Ductile iron+NRB/EPDM |
Disc | QT450-10 |
Stem | 45/2Cr13 |
O-Ring | NBR/EPDM |
1. Structure and size conform to GB/T12221, small size, light
weight, easy to operate.
2.90 degrees operation quickly open; The plate has high strength,
large flow area, small flow resistance and energy saving.
3. The medium can flow from both sides of the flange disc valve in
any direction, can achieve the purpose of connecting or cutting
off.
4. Small operating torque, labor-saving and lightweight.
5. The number of opening and closing experiments is up to ten
thousand times, and the service life is long.
6. Complete seal, zero gas test leakage.
1. The turbine head shall not be used for lifting, and auxiliary
levers shall not be added during operation.
2. The valve shall not be subjected to large external forces after
installation.
3. When the local minimum temperature is lower than 4 ° C, take
insulation protection. As the end valve should be used with pipe or
jacket heating, to prevent the pipe wall temperature below 0℃.
4. It is strictly prohibited to install and use in the pipeline
under vibration or the rapid change of medium temperature.
5. The operating condition shall be consistent with the
requirements in the performance specification.