Home /Measuring & Analysing Instrument Processing Services /

NYRD808 Radar Level Meter Handheld Ultrasonic Water Level Sensor

NYRD808 Radar Level Meter Handheld Ultrasonic Water Level Sensor

Brand Name:NUOYINGJIAYE
Certification:CE/ExiaⅡCT6 Ga,ExdⅡCT6 Gb
Model Number:NYRD808
Minimum Order Quantity:1 pcs
Delivery Time:7 working days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Address: Block V5, Ronghao Industrial Town, Gaoling District, Xi'an City, Shaanxi Province
Supplier`s last login times: within 28 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Handheld Ultrasonic Water Level Sensor Radar Level Meter


Description

This series of radar level meter adopted 26G high frequency radar sensor, the maximum measurement range can reach up to 70 meters. Antenna is optimized further processing,
the new fast microprocessors have higher speed and efficiency can be done signal analysis, the instrumentation can be used for reactor, solid silo and very complex measurement environment.

Detailed Images


Specification


HHandheld Ultrasonic Water Level Sensor Radar Level Meter
ApplicationAll Kinds of Corrosive Liquid
Measuring Range10 Meters
Process ConnectionThread, Flange
Medium Temperature-40℃ ~ +120℃
Process Pressure-0.1 ~ 0.3 Mpa
Accuracy±5mm
Protection GradeIP67
Frequency Range26GHz
Signal Output4~20mA/Hart (Two-wire/Four) RS485/Modbus
Explosion-proof GradeExia II C T6 Ga

Principle

Radar level transmitter antenna microwave pulse is narrow, the downward transmission antenna. Microwave exposure to the medium surface is reflected back again by the antenna system receives, sends the signal to the electronic circuit automatically converted into level signals (because the microwave propagation speed, electromagnetic wave to reach the target and the reflected back to the receiver this time is almost instantaneous).

Datum measurement: Screw thread bottom or the sealing surface of the flange.
Note: Make sure the radar level meter the highest level cannot enter the measuring blind
area (Figure D shown below).

Features


Ø Small antenna size, easy to install; Non-contact radar, no wear, no pollution.

Ø Almost no corrosion, bubble effect; almost not affected by water vapor in the atmosphere, the temperature and pressure changes.

Ø Serious dust environment on the high level meter work has little effect.

Ø A shorter wavelength, the reflection of solid surface inclination is better.

Ø Beam angle is small, the energy is concentrated, can enhance the ability of echo and to avoid interference.

Ø The measuring range is smaller, for a measurement will yield good results.

Ø High signal-to-noise ratio, the level fluctuation state can obtain better performance.

Ø High frequency, measurement of solid and low dielectric constant of the best choice.


The Installation Requirements

Installation guide:


Be installed in the diameter of the 1/4 or 1/6. Note: the distance between the tank wall minimum distance should be tank high 1/10.


Note: 1. datum

2.The container center or axis of symmetry


The top conical tank level, can be installed at

the top of the tank is intermediate, can guarantee the measurement to the conical bottom.

A feed antenna to the vertical alignment surface. If the surface is rough, stack angle must be used to adjust the angle of cardan flange of the antenna to the alignment surface.


(Due to the solid surface tilt will cause the echo attenuation, even Loss of signal.)


Typical installation errors:


Ø Conical tank cannot be installed above the feed port.

Note: outdoor installation should adopt sunshade.


1. Correct

2. Error rainproof measures


Ø The instrument cannot be installed in the arched or domed roof intermediate. In addition to produce indirect echo is also affected by the echoes. Multiple echo can be larger than the real value of signal echo, because through the top can concentrate multiple echo. So cannot be installed in a central location.

1. Correct

2. Error


Ø There are obstacles affecting measurement needed reflection plate.

1. Correct

2. Error


The Electrical Connection


The power supply voltage:


(4~20)mA/HART (Two wire system)


The power supply and the output current signal
sharing a two core shield cable. The supply voltage range see technical data. For intrinsically safe type must be a safety barrier between the power supply and the instrument.


(4~20)mA/HART(Four wire system)


Separate power supply and the current signal,
respectively using a power cable. The supply voltage range see technical data.


RS485 / Modbus


Power supply and Modbus signal line separate drespectively using a shielded cable, the power supply voltage range see technical data.


FAQ

Q:How long will you reply me?

A:We will contact you as soon as possible but within 12 hours

Q: Can I get some samples?

A: Yes, Sample order is available for quality check and market test. But you have to pay the express cost.

Q: How soon can you arrange your production?

A: Once getting your product confirmation and receiving the prepayment, the production will be started immediately.

Q: What's delivery time?

A: It usually takes about 3-5 working days for small order and 10-15 days for big order.

Q:How do you control your quality ?

A: Three inspection steps(of original, production, and finished goods) + good warranty service(1 year free to change a new one without any human damage factors).

Q: What certificates do you have ?

A:ISO9000, CE, Explosion-proof certification, RoHs ready. And before the delievry of goods, quality and safety inspection certification issued by third parts also can be offered.

Q:Could I visit your factory?

A:Very welcome! Fly to Xian Yang air port. It was a big pleasure for us.

Q: What's your warranty terms?

A: We offer 12 months warranty time.

Q:can you provide OEM & Customized service?

A:Yes, OEM and ODM are both available, we have the professional R&D dept which can provide professional solutions for you.


Technical parameter



ApplicationAll kinds of liquids (strong corrosion, low dielectric constant, stirring, steam, crystallization, condensation, slurry, high temperature and high pressure, etc.)
All kinds of dust (strong dust, floating dust, cement powder, lime powder, fly ash, crystallization and other occasions)
Various solids (grain, small stones, iron ore, coal, etc.)
Item numberNYRD805,NYRD806,NYRD807,NYRD808,NYRD809,NYRD810,NYRD86
NYRD87,NYRD-PB,NYRD-SD,NYRD-TJ,NYRD- SL
Antenna formBar type, water drop type, plate type, horn type, surface type, lens type
The antenna materialPTFE,304,316,PP,PFA
Measuring range10m,20m,30m,35m,40m,80m
Accuracy of measurement0.05%~0.1%F.S
Power supply24VDC(two wire,four wire),220VAC
Signal output4-20mA/HART/RS485/Modbus...
The process temperature-40~+130℃,-40~+150℃,-40~+2600℃,-40~+1200℃
Process pressure-0.1~0.3Mpa,-0.1~2.0Mpa,-0.1~4.0Mpa,
Process connectionThread, bracket, flange,Health clamp (optional)
Electrical interfaceM20x1.5,1/2”NPT
Protection gradeIP65,IP67,IP68(optional)
Explosion-proof gradeExiaIICT6 Ga,ExdIICT6 Gb(As shown in the certificate)

If you have any other further questions, please contact us. We will process your requests as soon as possible.

Serena Jiang / Sales Manager

Phone/WhatsApp:+86 15934851597


China NYRD808 Radar Level Meter Handheld Ultrasonic Water Level Sensor supplier