Add to Cart
PP Twisted Bundle Fiber
1. Ration design of the fibre concrete:
Generally the recommended amount to add to the concrete is more
than 2.7kg per sqm (volume ratio is 0.3%), reinforcement adding
amount is 5.5kg, Compared with adding 47kg of steel fibre, 5.4kg
polymer fibre has the same volume ratio to the concrete.
2. Length: 54mm for common crack-resistant requirement.
3. Matching Ratio:
Usually, it is no need to Change the matching ratio of the
concrete. Considering the requirement of fissure-resistant, the
polymer fiber is recommend to combine with the PP fiber mesh form
with the volume ratio of 1:1(0.9kg fiber-mesh to per sqm of cement
concrete). .
4. Mixer Adoption:
Double-axle horizontal compelling mixer is priority.
5. Mixing process:
Crushed stones, fibers and sands are put into the mixer in
succession. After stirring for two minutes, fiber will fully spread
and then add cement and water and stir normally. The addition of
materials also can be put into as common concrete, but the stirring
time should be properly prolonged to combine with the PP fiber mesh form with the volume ratio of
1:1(0.9kg fiber-mesh to per sqm of cement concrete).
make fiber com-pletely mixed
6. Shaping & Maintenance:
There is no special requirement, may along the vibrating time for
30s, The maintenance of the fibre concrete should be done same as
the normal
concrete.
Specification
Raw Material | PP/PE |
Elastic Modulus | ≥5000Mpa |
Length | 54mm (+/-5%) |
Diameter | 0.7mm(+/-5%) |
MeltPoint | 170℃ |
Density | 0.91/cm3 |
BreakStrength | 600 Mpa |
Break tensile ratio | 15 min. |
Appearance | Twisted Bunchy |
acid&alkali resistance | Excellent |