TUV CE RED SAA Lighting Occupancy Sensor 2 In 1 Interior Motion Sensor

Brand Name:HAISEN
Certification:CE TUV RED SAA
Model Number:HT18V-I
Minimum Order Quantity:100PCS
Delivery Time:1-3 days for sample order, 1-2 weeks for bulk order
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: 13th Floor, C1 Building, Songshan Lake Intelligent Valley, Liaobu Town, Dongguan City, 523808, Guangdong.
Supplier`s last login times: within 48 hours
Product Details Company Profile
Product Details

TUV CE RED SAA Lighting Occupancy Sensor 2 In 1 Interior Motion Sensor


2 In 1 LED Lighting Occupancy Sensor , Interior Motion Detector Efficiency Of 85%


220-240VAC 18W LED Driver & Sensor 2-in-1 Isolated Solution with 5.8GHz Microwave Motion Sensor and 24-42V Output Voltage


Features:

1. Max. mounting height x detection range: 6M x 14M.

2. Empty Load voltage of 55V max.

3. Optional detection area, hold time, stand-by dimming level, stand-by period and daylight threshold.

4. Efficiency of 85%

5. Input current 0.14-0.2A max. with power of 33W.

6. Optional Output current of 0.45A/0.55A/0.60A/0.70A for different projects.


Product Description

Input voltage220~240VAC 50/60Hz
Input current0.08-0.14A Max
Input power20W Max
Detection area50%/100%
Hold time5s/90s/ 5min/10min
Daylight threshold2Lux /10Lux /50Lux/Disable
Stand-by period0s/10s/10min /+∞
Stand-by dimming level10%/30%
Microwave frequency5.8GHz±75MHz
Microwave power<0.3mW
Detection angle30°-150°
Mounting heightMax.6m
Detection rangeMax.ø14m
Output LED current0.3A/0.35A/0.45A/0.50A
Output LED voltage24-42V/24-42V/24-42V/24-40V
Output LED power8-15W/10-16W/12.5-18W/14-18W
Empty load voltage≤55V
Power factor>0.9
Efficiency85% (Max.)
Operating temperatureTa: -20°C+50°C Tc: 80°C
Abnormal protectionSCP:Auto recovery,OVP,OCP,OTP
EMC standardEN55015
Safety standardEN61347-1 EN61347-2-13 EN60598-1
IP ratingIP20
Life time30,000 hours
Warranty3 years

Detection Range

This figure indicates the maximum distance at the highest mounting height with 100% sensitivity.

Typical installation height 2.5-6m.


Mechanical structure

With eight DIP switch poles to set all parameters

With two DIP switch poles to choose different output current

With two installation hole, easily fixed to the lighting fixture for end user.


Wiring diagram


Dimensions (mm)


DIP Switch Setting


Detection area Hold-time Daylight threshold Stand-by period Stand-by dimming level

In this area, The period of Definition of the The period of light The definition of
movement will light keeping ambient brightness; keeping low output low output in the
be detected 100% brightness only when the before it's standby period.
and able to after moving ambient brightness completely
trigger the objects leave the is lower than the switched off. When
sensor. 100% detection area. preset specific lux it's preset as"∞“,
detection area amount, the sensor the light always
is also known will work; when it's keep at low output
as the strong preset as "disable", if no movement in
sensitvity. the sensor works the detection area

everytime it detects and doesn't turn off.
motion regardless
the ambient brightness.

Application Demo

1. Automatically ON/OFF function:

Light on when detect movement and off after people leave at night. Applications: Corridor, Staircase.
The daylight threshold is set to "2lux,10lux,50lux"


With sufficient daylight, With insufficient daylight, After the last detection and
even when motion detected, when motion detected, light ON. the present hold time
light remains OFF. elapsed, light OFF.

2. No daylight function
The daylight threshold is set to "Disable".
Light on when detect movement, After people leave, Light off after stand-by period.
Applications: Dim places such as Basement Parking, Underpass.


When motion is detected, After people leave the detection After the last detection and
the sensor will switch on the area, light remains 100% the present hold time
light to 100% brighteness. brightness within hold time. elapsed, light OFF.

3. Function Demo - Dimmable control/Corridor function


With sufficient daylight, With insufficient After last detection, After the stand-by
even when motion daylight, when motion light will be dimmed period, light OFF.
detected, light remains detected, light ON. down to the stand-by
OFF. dimming level (10% or

30%) after holdtime.

Installation Method:


User Notes:

1. Suitable for indoor installation to avoid false triggering due to external factors such as rain, wind or tree swing.
2. Shall not be installed in the place with all four metal shelters and small space (such as galvanized-iron roof ).
3. Shall note be mounted installation, so as to avoid false trigger caused by the lamp itself shaking.
4. Shall not be installed next to large operating machines such as ventilator/ceiling fan to avoid false triggering caused by machine vibration.


HT18V-I.pdf