Home /Inductors /

Remote Control Plane Antenna Indoor Light Motion Sensor

Remote Control Plane Antenna Indoor Light Motion Sensor

Brand Name:HAISEN
Certification:RoHS CE
Model Number:HT30VR
Minimum Order Quantity:100PCS
Delivery Time:1-3 days for sample order, 2-3 weeks for bulk order
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: 13th Floor, C1 Building, Songshan Lake Intelligent Valley, Liaobu Town, Dongguan City, 523808, Guangdong.
Supplier`s last login times: within 48 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Plane Antenna Remote Control Build-in Dial Code RoHS CE Certification


Features:

1.Constant current output.

2.On/off control by relay.

3.Tri-level control by 1-10V output.

4.Suitable for ceiling lights and Bulkhead.

5.Sensitive and reliable.

6.All parameters could be set by remote control.

7.IP 20 and 3 years warranty.


Technical data:

Model numberHT30VR
Input voltage220-240VAC,50Hz/60Hz
Input current0.18-0.15A Max
Input power35W Max
Output LED current

0.45A/0.55A/0.60A/0.70A±5%

Output LED voltage

33V-43V DC

Output LED power

Max.30W

Stand-by power

0.5W(230VAC)

Empty load voltage≤60V DC
Power factor≥0.9
Efficiency

≥89% (Max.)

Microwave frequency5.8GHz±75MHz
Microwave power<0.3mW
Detection area100%/75%/50%/25%
Hold time5s/30s/1min/3min/5min/10min/20min/30min
Daylight thresholdDisable/120Lux/80Lux/50Lux/30Lux/10Lux/2Lux
Stand-by period0s/10s/30s/1min/5min/10min/30min/+∞
Stand-by dimming level10%/20%/30%/50%
Mounting height
Max 6m(ceiling mounted)
Deteation range
Max.ø14m (ceiling mounted)
Motion detection0.5–1.5m/s
Packing method

①the bubble pack,

②paper flat,

③outer carton(400*300*236mm)with drying agent(The sensor 100pcs/carton,gross weight 9.78kg)

Detection angle30°-150°
Operating temperature

Ta: -20°C~55°C Tc: 85°C

Abnormal protectionSCP:Auto recovery,OVP,OCP,OTP
EMC standardEN55015
Safety standardEN61347-1 EN61347-2-13 EN60598-1
IP ratingIP 20
Warranty3 years

On/Off Control Detection Area Hold Time Daylight Sensor


Stand-by dimming Stand-by Output Current Remote Control

level Period


Dtection Area:

The fixture indicates teh maximun distance at the highest mounting height with 100% sensitivity.

Typical installation height 2.5-6M.

Mechanical structure:


Dimensions:


Wiring diagram:


Daylight periority:

Dusk/Dawn sensor:

Our special active photocell technology can tell the difference between natural light and LED light, to

ensure the light will be off when needed.

With Daylight priority function, HT30V is able to differentiate artificial light brightness from

natural light after installed inside the fixture, and automatically turn off light when ambient
brightness exceeds preset lux level.
Precondition of Daylight priority:
1. Standby period is +∞;
2. Standby dimming level is on 10% or 30%;
3. Daylight threshold is on 2Lux, 10Lux or 50Lux.

Lux on/off:

Light automatically With insufficient Lights dims to standby Light off when

on when ambient ambient brightness level if no motion ambient lux level is

brightness is lower light dims to 100% detected after higher than preset

than preset lux level. when motion holdtime. Lux mount.

detected.


Application:

1.Automatically ON/OFF function:

Light on when detect movement and off after people leave at night.Applications:Corridor,Staircase.The daylight threshold is set to"2Lux,10Lux,50Lux".

With sufficient daylight,even With insufficient daylight, After the last detection and the

when motion detected,light when motion detected, present hold time elapsed,

remains OFF. light ON. light OFF.

2.No daylight function:

The daylight threshold is set to"Disable".Light on when detect movement,after people leave,light off after stand-by period,Applications:Dim places such as basement parking ,underpass.


When motion is detected, After people leave the After the last detection and

the sensor will switch on the detection area,light remains the present hold time

light to 100% brightness. 100% brightness within elapsed,light OFF.

hold time.

3.Function demo-dimable control/corridor function

With sufficient daylight,even With insufficient daylight, After the last detection the light

when motion detected,light when motion detected, will be dimmed down to the

remains OFF. light ON. stand-by dimming level

(10% or 30%)after hold time

After the stand-by period,

light OFF.

Installation Method:


Application:


User Notes:

1.Microwave can penetrate walls or glass thinner than 20cm and attenuate if thicker than 20cm.
2.The driver voltage shall be stable and float within 10%.
3.Detection area will be affected by speed of motion, mounting height and movement volume.
4.Conduct test on sunny days without the lampshade which will affect the tested lux value.

Remote Control Application:

1.Press "ON/OFF button "to turn on the light or off.

2.To reset the parameters,Please follow the steps as below:

Step 1-press ON,to turn on the light if it was off at the start.

Step 2-press "Start" to the well-setting sensor

Step 3-press the button of detection rang,hold time,stand-by dimming level,stand-by period and daylight threshold one after the other in sequence(press"+/-"to set parameters).

Step 4-press "Memory" to memorize the settings.

(Note:The interval of each parameter setting shall be controlled within 30s)

3.To programme other lights in the array that have similar sensors to the same programme.

Step 1-press"ON" to the second sensor

Step 2-press"Apply".


Remark:Factory default setting:detection area 100%/hold time 5s/daylight threshold disable/satnd-by period 0s/stand-by dimming level 10%.



China Remote Control Plane Antenna Indoor Light Motion Sensor supplier

Remote Control Plane Antenna Indoor Light Motion Sensor

Inquiry Cart 0