Add to Cart
Butterfly Special wavelength Laser Source High stability ± 2nm
UC8131 Special wavelength Laser Source
We mentioned
UC812n/UC813n multi-channel laser source can be used for WDM CWDM
devices, high precision WDM devices, optical waveguide grating
array AWG devices, planar optical waveguide PLC devices, optical
amplifier EDFA and other general fiber optics measurement and
application. In particular, it is suitable for the mass production
and detection of PLCS of couplers and planar optical waveguides.
Special point
UC812n/UC813n multi-channel laser source has the characteristics of
high output stability, small size, fast start-up and so on. Light
source equipment can provide multiple channels of fixed wavelength
light source output signal. Guangzhou youxi can also customize 850,
980, 1250,1270... 1610,1625 nm and any combination of two or four
or more wavelength light source equipmen.
Product Interface Description
The front of the instrument
At the back of the instrument
The power supply requirements
The instrument complies with overvoltage class II regulations. The
operating voltage is 100 ~ 240V AC voltage, the frequency range is
48 ~ 66Hz, the operating voltage is 115V, the maximum consumption
current is 230mA; When the operating voltage is 230V, the maximum
consumption current is 120mA.
Communication Interface Description
There are two communication ports on the back panel of the
instrument, namely USB and RS232 interface.
The USB interface
USB interface is a standard 4-core B-type interface, which can be
connected to the instrument and PC, and the instrument can be
controlled by monitoring software.
RS232 interface
The serial port parameters of the instrument are set to a fixed
value. The serial port parameter Settings of the computer must
match the instrument parameter Settings.
Light source output interface
Light source connector interface for laser signal output. Select
FC/PC or FC/APC connectors and SMF or MMF fibers according to the
fiber type label on the instrument panel.
The wavelength annotation displays the wavelength value of the
corresponding channel.
Channel switch button
After the instrument is powered on, turn on the power switch and
the indicator light of the channel switch button starts to blink.
At this time, the instrument enters the self-test state and the
channel indicator light goes out after the self-test is completed.
The operator should select the corresponding channel port according
to the required wavelength, touch the switch button lightly, and
light the indicator light. If the switch button of the channel is
steady on, it means that the laser of the corresponding channel has
been turned on and can be used.