On Off Inverter Fixed Speed Air Conditioner R410A Split Home Appliance

Brand Name:DELTA
Certification:ISO9001
Model Number:Fixed Speed Air Conditioner
Minimum Order Quantity:50 sets
Delivery Time:20-25days
Payment Terms:T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Active Member
Location: Guangzhou China
Address: Room 914, Tower C, Guangsheng Wanbo City, Panyu District, Guangzhou
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details

Home Appliances Residential on-off and Inverter R410A Split Air Conditioner


Product Features:
1: World famouns brand rotary type compressor;
2: High Efficient Internal Thread Copper pipe for condensor and evaporator;
3: LED digital display, Best Visibility
4: Self-diagnose capability, error code showing for detection convenience;
5: Intelligent Defrost, Independent Dehumidification, Sleep Mode, Quiet Operation;
6: Low Voltage Startup, Auto-protection, Auto Restart;
7: Optional Refrigerant: R410A & R22;
8: Optional Voltage: 220V/50Hz & 220V/60Hz;

Reverse Cycle Fixed Speed Models Specifications
Model7K9k12k12k18k
GSC-07HAGSC-09HAGSC-12HA/AGSC-12HA/BGSC-18HA
Typeheating pumpheating pumpheating pumpheating pumpheating pump
Control typeremoteremoteremoteremoteremote
Rated cooling capacityBtu/h;W7000;20509000;264012000;352012000;352018000;5280
Rated heating capacityBtu/h;W7500;22009500;280012500;370012500;370018500;5420
EER for coolingW/W10.98;3.2210.98;3.2210.95;3.2110.95;3.2111.02;3.23
Class in CoolingAAAAA
COP for heatingW/W3.613.613.623.623.61
Class in HeatingAAAAA
Moisture removalLiters/h0.811.21.22
PressureHigh(DP)MPa4.54.54.54.54.5
Low(SP)MPa1.91.91.91.91.9
Indoor noise level(S/H/M/L/Mute)dB(A)35/33/29/27/2535/33/29/27/2543/40/37/33/3143/40/37/33/3143/40/38/37/37
Outdoor noise leveldB(A)5050525255
Electrical Data
Power supply220-240V~/50Hz/1P220-240V~/50Hz/1P220-240V~/50Hz/1P220-240V~/50Hz/1P220-240V~/50Hz/1P
Voltage RangeV198~264198~264198~264198~264198~264
Rated currentCoolingA2.953.85.15.17.6
HeatingA2.833.64.74.77
Rated inputCoolingW640820110011001640
HeatingW610775102010201500
Annual energy consumption(cooling)kwh350410550550820
Max CurrentCoolingA4.64.96.66.69.9
HeatingA4.64.96.66.69.1
Max Power inputCoolingW10001060143014302130
HeatingW10001060143014302130
Refrigerating&Fan System
Refrigerant/ChargekgR410A/0.380R410A/0.420R410A/0.630R410A/0.630R410A/0.930
CompressorTypeASN82V1UDZASN86V1UDZASM135V1VDZASM135V1VDZPA190M2AS-4KUL1
ModelGMCCGMCCGMCCGMCCGMCC
BrandRotaryRotaryRotaryRotaryRotary
Expansion deviceCapillary tubeCapillary tubeCapillary tubeCapillary tubeCapillary tube
Indoor air circulation(Cooling/Heating)m3/h5605606506501100
Indoor fan motortypeCross flowCross flowCross flowCross flowCross flow
OutputW1313212125
CapacitoruF1.21.21.51.51.5
Indoor fan speed H/M/LCoolingrpm125011501050950900125011501050950900125011501050950900125011501050950900125011501050950900
Heatingrpm125011501050950900125011501050950900125011501050950900125011501050950900125011501050950900
Dryrpm900900900900900
Sleeprpm900900900900900
Evaporatora.Number of rows11222
b.Fin spacingmm1.31.31.41.41.4
c.Tube outside dia.and typemmΦ7,innergroove tubeΦ7,innergroove tubeΦ7,innergroove tubeΦ7,innergroove tubeΦ7,innergroove tube
Outdoor fan motortypePropeller fanPropeller fanPropeller fanPropeller fanPropeller fan
OutputW2525252555
CapacitoruF2.52.52.52.55
Speedr/min860860860860850
Condensera.Number of rows11111
b.Tube pitch(a)x row pitch(b)mm25×2225×2225×2225×2225×22
c.Fin spacingmm1.3-7U1.3-8U1.4-10U1.4-10U1.3-11U
d.Fin typeLouver FinLouver FinLouver FinLouver FinLouver Fin
e.Tube outside dia.and typemmΦ7.94,innergroove tubeΦ7.94,innergroove tubeΦ7.94,innergroove tubeΦ7.94,innergroove tubeΦ7.94,innergroove tube
Connections
Connecting PipeGasmmΦ9(3/8'')Φ9(3/8'')Φ9(3/8'')Φ9(3/8'')Φ12(1/2'')
LiquidmmΦ6(1/4'')Φ6(1/4'')Φ6(1/4'')Φ6(1/4'')Φ6(1/4'')
Connecting WiringSize x Core number3×1.0;2×0.753×1.0;2×0.753×1.5;2×0.753×1.5;2×0.753×1.5;2×0.75
Others
Suitable aream210~1515~2015~2315~2325~35
Max. refrigerant pipe lengthm1515151515
Max. difference in levelm55555
Operation temperature rangeºC16~3116~3116~3116~3116~31
Ambient temperature rangeOutdoorºCCooling:15-43/Heating:-7-24Cooling:15-43/Heating:-7-24Cooling:15-43/Heating:-7-24Cooling:15-43/Heating:-7-24Cooling:15-43/Heating:-7-24
IndoorºCCooling:17-32/Heating:0-27Cooling:17-32/Heating:0-27Cooling:17-32/Heating:0-27Cooling:17-32/Heating:0-27Cooling:17-32/Heating:0-27
Net dimensions
(W x D x H)
Indoormm750*262*195750*262*195840*290*198807*288*211970*308*200
Outdoormm630*236*500630*236*500730*280*550730*280*550790*372*598
Net weightIndoorkg7.57.58.58.510.5
Outdoorkg2425303035
Packing dimensions
(W x D x H)
Indoormm835*333*273835*333*273912*345*263879*343*2661035*378*278
Outdoor(w/i pipe)mm760*348*525760*348*525847*371*602847*371*602941*412*663
Gross weightIndoorkg8.58.59.59.511.5
Outdoor(w/i pipe)kg2930353541
Loading Capacity w/i pipe40'HQ325325253252187

Precautions

- The outdoor unit must be installed firmly to reduce vibration and noise. There must be enough space in front of the suction and exhaust vents of the condenser for ventilation. If the wind is blocked, the condensation pressure will increase and it will cause shutdown;

- There should be no obstacles in front of the indoor unit, otherwise the wind will be affected;

When the air conditioner is running for rapid cooling, the selector switch can be adjusted to the high gear, and after the temperature drops, it can be adjusted to the medium-speed low gear;

- The ventilation switch can be used for the ventilation of the window air conditioner, but the ventilation time should not exceed 15 minutes;

- The outdoor unit of split type air conditioner cannot be inserted with sticks, otherwise the fan will be stuck or damaged

- After the air conditioner is stopped, it must be restarted after three minutes to protect the compressor;


China On Off Inverter Fixed Speed Air Conditioner R410A Split Home Appliance supplier

On Off Inverter Fixed Speed Air Conditioner R410A Split Home Appliance

Inquiry Cart 0