IEC and British Standard Dissmann Fuse , BS 88 Low Voltage Fuses DC150V

Brand Name:Dissmann
Certification:UL 、 CCC
Model Number:BS88-HBD AC240/DC150V
Minimum Order Quantity:100pcs
Delivery Time:5-8 days
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Active Member
Location: Shenzhen China
Address: No.8, Baotian First Road, Shatian Community, Kengzi St, Pingshan District, Shenzhen City, China
Supplier`s last login times: within 10 hours
Product Details Company Profile
Product Details

Dissmann Fuse IEC & British Standard Fuses - BS 88 low voltage fuses DC150V Fuse Made in China



Dissmann British standard fuses can be used in multiple applications. Full range of rated current, voltage available as well as compatible fuse holders. They meet the BS88 and IEC 60269 standards.


240VAC/150VDC (6A-900A) BS88-HBD series fuse Model shows as below:

BS88-HBD240VAC/150VDC (6A-900A)
Product CodeRated Current AI²t(A²Sec)power consumptionModel
Pre-arcTotalW
HBD-25LEP/HBD-25LET2517.60246.03.96LEP/LET
HBD-32LEP/HBD-32LET3231.20442.04.75
HBD-35LEP/HBD-35LET3549.30590.04.90
HBD-50LEP/HBD-50LET5097.60136.56.80
HBD-63LEP/HBD-63LET63176.002120.08.95
HBD-80LEP/HBD-80LET80293.003695.09.70
HBD-100LEP/HBD-100LET100580.007300.010.20
HBD-125LEP/HBD-125LET125597.007380.015.80
HBD-160LEP/HBD-160LET1601060.0015440.019.00
HBD-180LEP/HBD-180LET1801540.0027950.021.00
HBD-160LMP/HBD-160LMT1601065.0015440.016.50LMP/LMT
HBD-200LMP/HBD-200LMT2001460.0019300.026.80
HBD-250LMP/HBD-250LMT2503100.0038670.028.00
HBD-315LMP/HBD-315LMT3155830.0072000.033.00
HBD-350LMP/HBD-350LMT3507760.0097200.034.70
HBD-400LMP/HBD-400LMT40013550.00153000.038.90
HBD-450LMP/HBD-450LMT45017470.00210100.042.30
HBB-500LMP/HBD-500LMT50021250.00259400.058.30
HBB-550LMP/HBD-550LMT55025500.00313000.076.00

Different models corresponding size chart of the BS88-HBD series fuse:


LEP/LET LMP/LMT


Time-current curve of the DC150V BS88-HBD series fuse:


LEP/LET LMP/LMT


Normal use conditions and parameter correction:

  • The fuse works under the following normal use conditions and does not require additional corrections.
  • When the normal use conditions are exceeded, if it is within the allowable use conditions, some parameters may need to be corrected or consulted.
  • If it exceeds the scope of the allowable use conditions, you should consult our company, and carry out the work suitability assessment and test of the conditions.
  • It is recommended that the current value of long-term flow should not exceed 80% of the rated current.
  • For over-temperature use, please refer to the temperature evaluation curve. ambient air temperature Normal use conditions: -5°C~40°C. Allowable operating conditions: -40°C~85°C.

China IEC and British Standard Dissmann Fuse , BS 88 Low Voltage Fuses DC150V supplier

IEC and British Standard Dissmann Fuse , BS 88 Low Voltage Fuses DC150V

Inquiry Cart 0