Digital RS485 Oxidation Reduction Potential Sensor Modbus Various Industries

Brand Name:Desun Uniwill
Model Number:DS525
Minimum Order Quantity:0-100pcs
Delivery Time:7-15 working days
Payment Terms:L/C, D/A, D/P, T/T
Place of Origin:China
Contact Now

Add to Cart

Site Member
Address: Room 502, Unit 2, Building 1, Yi Cui yuan i city, No. 11, Tangyan South Road, Yanta District, Xi'an city, Shaanxi Province, China.
Supplier`s last login times: within 19 hours
Product Details Company Profile
Product Details

China factory direct sale digital RS485 ORP sensor for water quality monitoring various industries supports Modbus

Overview

Desun Uniwill Digital ORP sensor adopts industrial on-line electrode and built-in temperature sensor, which can automatically compensate for temperature, and is suitable for long-term monitoring of online environment. The sensor adopts RS485 output and supports Modbus, which can realize networking and system integration without a controller.

Features

Range: -999 ~ 999mV Accuracy: ± 20mV

Resolution: 1mV

0 ~ 50 ℃;

IP68 protection, water depth within 10 meters

Built-in temperature sensor, automatic temperature compensation Digital sensor,

support RS-485, MODBUS protocol

Adopt high-performance industrial online electrode, can work stably for a long time


Technical parameter


ItemParameters
modelDS525
Range-999~999mV
Precision±20mV
Resolution1mV
Deepest depthUnderwater 30m
Protection levelIP68
Max operating pressure6bar
storage temperature0~ 60 °C
temperature range0~ 50°C

Sensor interfaceSupport RS-485, MODBUS protocol
assemblyInput type
Power informationDC 5~12V, current <50mA
sizeΦ 26 * 167.5 mm
Probe cable length10 meters (default), can be customized
Housing materialPOM, SS316

Maintenance methods and common problems

Maintenance schedule and method

Maintenance schedule

It is recommended to periodically calibrate or clean the sensor surface according to the actual application scenario.


Maintenance tasks,Recommended maintenance frequency
Calibrate the sensor (if required by the competent authority)According to the maintenance schedule required by the competent authority

Maintenance method

Sensor maintenance

  • External surface of the sensor: Wash the external surface of the sensor with tap water. If debris remains, wipe it with a moist soft cloth.
  • Check the cable of the sensor: The cable should not be tight during normal work, otherwise the internal wires of the cable will be easily broken and the sensor will not work properly.
  • Sensor storage: When the sensor is not in use, you should fasten the black plastic cap and check whether the sponge inside is wet. If it is not wet enough, please add 3mol / L potassium chloride solution and let the electrode be stored in the solution with potassium chloride.

Precautions

The probe contains sensitive optical and electronic components. Ensure that the probe is not subject to severe mechanical impact. Damage to the sensor due to impact or manpower will not be covered by the warranty. Water ingress to the sensor due to replacement of the ORP electrode is not covered by the warranty.


Frequently Asked Questions


ErrorPossible causesSolutions
The operation interface cannot be connected or the measurement results are not displayedController and cable connection errorReconnect the controller and cables
Cable failurePlease contact us
Measured values are too high, too low, or the values remain unstableMeasurement shiftedRecalibration
Water has entered the productPlease contact us
The ORP electrolyte is exhaustedReplace the ORP electrochemical part
China Digital RS485 Oxidation Reduction Potential Sensor Modbus Various Industries supplier

Digital RS485 Oxidation Reduction Potential Sensor Modbus Various Industries

Inquiry Cart 0