3 Parameter Etco2 Multi Parameter Patient Monitor Ambulance Patient Monitor

Brand Name:CONTEC
Certification:CE,ISO13485
Model Number:CMS5100
Minimum Order Quantity:2 Pieces
Delivery Time:about 5 days
Payment Terms:T/T, Western Union,Payoneer
Contact Now

Add to Cart

Active Member
Location: Hong kong China
Address: ROOM 702,7/F, SPA CENTRE,NO. 53-55 LOCKHART ROAD,WAN CHAI, HONG KONG
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details
Christmas

CONTEC CMS5100 Patient Monitor vital signs monitor NIBP SPO2 monitor

CMS5100 Patient Monitor adopts Oscillometry for NIBP measuring, Photoelectric Oxyhemoglobin Inspection Technology combining Capacity Pulse Scanning & Recording Technology for SpO2 measuring. Systolic Pressure(SYS), Diastolic Pressure(DIA), Mean Pressure(MAP), SpO2 and Pulse rate(PR) can be accurately measured.

Compact appearance, comprehensive functions, simple and convenient operation, which is applicable for hospitals, community medical treatment and family.



Features
Be applicable for adult, pediatric and neonatal for all-round monitoring, easy operation and high cost performance.
Be applicable for medicine, surgery, operating room, ICU/CCU, emergency room, obstetrics and gynecology, pediatrics.
Built-in rechargeable Li-polymer battery for uninterrupted monitoring.
Compact and flexible appearance, easy for carrying and be suitable for indoor and outdoor(in ambulance) monitoring.
With user-friendly interface.

Display with 2.8'' (320×240) color TFT LCD and red and yellow highlight LED.
Visual and audible alarm for Systolic Pressure(SYS), Diastolic Pressure(DIA), Mean Pressure(MAP), SpO2 and Pulse rate(PR), and upper and lower limit of alarm can be set.
Unique Flash memory, storage for up to 2000 NIBP data and 30000 SpO2 data.
Convenient and quick in inquiring measurement data, review for NIBP trend graph within 24-hour and SpO2 and Pulse rate(PR) trend graph within 20-hour.


Performance
1. NIBP monitoring
Measurement method: Oscillometry
Measurement mode: manual/auto/continuous.
Auto measurement interval: adjustable from 1 to 90 minutes.
Resolution: 1mmHg.
Accuracy: Maximum Mean deviation≤±5mmHg, Maximum Standard deviation≤8mmHg.
Self-check function.
Overpressure protection: double protection for software and hardware.
1) Range
Adult:
Systolic pressure: 40mmHg~270mmHg
Mean pressure: 20mmHg~235mmHg
Diastolic Pressure: 10mmHg~215mmHg
Pediatric:
Systolic pressure: 40mmHg~200mmHg
Mean pressure: 20mmHg~165mmHg
Diastolic Pressure: 10mmHg~150mmHg
Neonatal:
Systolic pressure: 40mmHg~135mmHg
Mean pressure: 20mmHg~110mmHg
Diastolic Pressure: 10mmHg~100mmHg
2) Upper and lower limit of alarm
Adult:
Systolic pressure: 40mmHg~270mmHg
Mean pressure: 20mmHg~235mmHg
Diastolic Pressure: 10mmHg~215mmHg
Pediatric:
Systolic pressure: 40mmHg~200mmHg
Mean pressure: 20mmHg~165mmHg
Diastolic Pressure: 10mmHg~150mmHg
Neonatal:
Systolic pressure: 40mmHg~135mmHg
Mean pressure: 20mmHg~110mmHg
Diastolic Pressure: 10mmHg~100mmHg


2. SpO2 monitoring
Continuous real-time measuring.
Adopt digital SpO2 technology, which has strong anti-interference capability.
Real-time display SpO2, pulse rate, SpO2 Plethysmogram, bar graph, SpO2 and Pulse rate(PR) trend graph.
Standard finger-clip probe for adult , binding probe for neonatal is optional.
1) SpO2 Measuring
Range: 35%~100% (Resolution: 1%)
Accuracy: ±2% in stage of 70%-100%, and unspecified in stage of less than 70%.
2) Pulse Rate Measuring
Range: 30bpm~250bpm(Resolution: 1bpm)
Accuracy: ±2bpm or ±2%, whichever is greater.
3) Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown
correctly when pulse-filling ratio is 0.4%, SpO2 error is ±4%; the Pulse rate error is ±2bpm or ±2%, whichever is greater.
4) Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.


Accessories
A power cord
A power adapter
A SpO2 probe
An adult NIBP cuff
An extending tube for blood pressure


Physical characteristic
Dimension for prodult: 190(L)×162(W)×240(H)mm
Weight: 1.6kg
Dimension for packaging: 402(L)×228(W)×320(H)mm

Patient Monitor

Multi-parameter Patient Monitor series: $150-600


ModelParametersParameters(detail)

Screen size
(inch)

Touch
screen

Central

Monitoring

WIFI/
Cellular
Printer
PM502NIBP/SPO22.4NNNN
CMS50002NIBP/SPO22.4NNNN
CMS5000C2NIBP/SPO22.4NNNY
CMS51003NIBP/SPO2/TEMP2.8NNNN
CMS65006NIBP/SPO2/TEMP/ECG/RESP/PR7YYYY
CMS60006NIBP/SPO2/TEMP/ECG/RESP/PR8NYYY
CMS70006NIBP/SPO2/TEMP/ECG/RESP/PR12.1NYYY
CMS7000 PLUS6NIBP/SPO2/TEMP/ECG/RESP/PR12.1YYYY
CMS80006NIBP/SPO2/TEMP/ECG/RESP/PR12.1NYYY
CMS90006NIBP/SPO2/TEMP/ECG/RESP/PR12.1NYYY
CMS68006NIBP/SPO2/TEMP/ECG/RESP/PR8NYYY
CMS92006NIBP/SPO2/TEMP/ECG/RESP/PR15NYYY
CMS9200 PLUS6NIBP/SPO2/TEMP/ECG/RESP/PR15YYYY
HMS65009NIBP/SPO2/TEMP/ECG/RESP/PR7YNYN
HMS75009NIBP/SPO2/TEMP/ECG/RESP/PR10.1YNYN

For model CMS6000/6500/6800/7000/7000 PLUS/8000/9000/9200/9200 PLUS, optional functions are:

IBP, ETCO2, 12 LEAD ECG, BUILT-IN PRINTER, VGA OUTPUT, CO, MOVING BRACKET,HANGING BRACKET.


China 3 Parameter Etco2 Multi Parameter Patient Monitor Ambulance Patient Monitor supplier

3 Parameter Etco2 Multi Parameter Patient Monitor Ambulance Patient Monitor

Inquiry Cart 0