Ferritin Rapid Test Reader Diagnostic Test Cassette CE Quantitative
detection with LF Reader.
Product features | Parameters |
Principle | Chromatographic Immunoassay |
Format | Cassette |
Specimen | WB/S/P |
Certificate | CE |
Reading Time | 5 minutes |
Pack | 10 T |
Storage Temperature | 2-30°C |
Shelf Life | 2 Years |
Sensitivity | 91.30% |
Specificity | 96.20% |
Accuracy | 93.80% |
Cut-Off | 13ng/mL |
High quality Ferritin Rapid Test Diagnostic Test Cassette CE Mark
Application:
The Ferritin Rapid Test Cassette (Whole Blood/Serum/Plasma) is a
quantitative, lateral flow immunoassay for the detection of human
ferritin in human serum or plasma and whole blood. The membrane is
precoated with anti-ferritin polyclonal antibody on the test line
region. And the membrane is precoated with Goat anti Rabbit IgG on
the reference line region.
The gold is precoated with anti-ferritin monoclonal antibody and
Rabbit IgG. During testing, the specimen reacts with the particle
coated with anti-ferritin monoclonal antibody. The mixture migrates
upward on the membrane chromatographically by capillary action to
react with anti-ferritin polyclonal antibody on the membrane and
generate a colored line.
The line in test line region (T) appears, if the ferritin level
exceeds the cut-off level of 13ng/ml. If the ferritin concentration
is less than 13ng/ml, the test line not appears. To serve as a
procedural control, a colored line will always appear in the
control line region, indicating that the proper volume of specimen
has been added and membrane wicking has occurred.
How to use?
Allow the test, specimen, buffer and/or controls to reach room
temperature (15-30°C) prior to testing.
Exact QR Code from the QR code card for specific information of the
test. Use only QR code card provided inside the test kits.
For serum or plasma specimen:
1. Bring the pouch to room temperature (15-30℃) before opening it.
Remove the cassette from the sealed pouch and use it within one
hour.
2. Place the cassette on a clean and level surface. Hold the
dropper vertically and transfer 1 full drop of serum or plasma
(approximately 25μL) to the specimen well of the cassette, then add
1 drop of buffer (approximately 40μL) and start the timer. Avoid
trapping air bubbles in the specimen well. See illustration below.
3. Wait for the colored line(s) to appear. The result should be
read with LF Reader at 5 minutes.
4. Do not interpret test results visually.
5. For LF Reader installation, start up and complete instructions
refer to AllTestTM LF Reader User Manual. Operator must consult LF Reader User Manual
prior to use and become familiar with the processes and quality
control procedures.
For whole blood specimen:
1. Bring the pouch to room temperature before opening it. Remove
the test cassette from the sealed pouch and use it as soon as
possible.
2. Place the cassette on a clean and level surface.
For Venipuncture Whole Blood specimen:
Hold the dropper vertically and transfer 2 drops of whole blood
(approximately 50μL) to the specimen well, then add 1 drop of
buffer (approximately 40μL), and start the timer. See illustration
below.
For Fingerstick Whole Blood specimen:
To use a capillary tube: Fill the capillary tube and transfer
approximately 50μL of fingerstick whole blood specimen to the
specimen well of test cassette, then add 1 drop of buffer
(approximately 40μL) and start the timer. See illustration below.
3. Wait for the colored line(s) to appear. The result should be
read with LF Reader at 5 minutes.
4. Do not interpret test results visually.
5. For LF Reader installation, start up and complete instructions
refer to LF Reader User Manual. Operator must consult LF Reader
User Manual prior to use and become familiar with the processes and
quality control procedures
INTERPRETATION OF RESULTS
Results read by the LF Reader
The result of positive or negative for calprotectin is determined
by LF Reader.
Result could be exported to excel or PDF. Other clinically
available tests are rquired if questionable results are obtained.
Cat. No. | Product | Specimen | Pack |
OFE-R402 | Ferritin Rapid Test Cassette | WB/S/P | 10 T |